32,389 research outputs found

    Adaptive control system for line-commutated inverters

    Get PDF
    A control system for a permanent magnet motor driven by a multiphase line commutated inverter is provided with integration for integrating the back EMF of each phase of the motor. This is used in generating system control signals for an inverter gate logic using a sync and firing angle (alpha) control generator connected to the outputs of the integrators. A precision full wave rectifier provides a speed control feedback signal to a phase delay rectifier via a gain and loop compensation circuit and to the integrators for adaptive control of the attenuation of low frequencies by the integrators as a function of motor speed. As the motor speed increases, the attenuation of low frequency components by the integrators is increased to offset the gain of the integrators to spurious low frequencies

    Space Shuttle booster thrust imbalance analysis

    Get PDF
    An analysis of the Shuttle SRM thrust imbalance during the steady-state and tailoff portions of the boost phase of flight are presented. Results from flights STS-1 through STS-13 are included. A statistical analysis of the observed thrust imbalance data is presented. A 3 sigma thrust imbalance history versus time was generated from the observed data and is compared to the vehicle design requirements. The effect on Shuttle thrust imbalance from the use of replacement SRM segments is predicted. Comparisons of observed thrust imbalances with respect to predicted imbalances are presented for the two space shuttle flights which used replacement aft segments (STS-9 and STS-13)

    Airframe Noise Reduction Studies and Clean-Airframe Noise Investigation

    Get PDF
    Acoustic wind tunnel tests were conducted of a wing model with modified leading edge slat and trailing edge flap. The modifications were intended to reduce the surface pressure response to convected turbulence and thereby reduce the airframe noise without changing the lift at constant incidence. Tests were conducted at 70.7 and 100 m/sec airspeeds, with Reynolds numbers 1.5 x 10 to the 6th power and 2.1 x 10 to the 6th power. Considerable reduction of noise radiation from the side edges of a 40 deflection single slotted flap was achieved by modification to the side edge regions or the leading edge region of the flap panel. Total far field noise was reduced 2 to 3 dB over several octaves of frequency. When these panels were installed as the aft panel of a 40 deg deflection double slotted flap, 2 dB noise reduction was achieved

    Poincaré maps define topography of Vlasov distribution functions consistent with stochastic dynamics

    Get PDF
    In a recent paper [A. D. Bailey et al., Phys. Rev. Lett. 34, 3124 (1993)], the authors presented direct planar laser induced fluorescence measurements of the oscillatory ion fluid velocity field in the presence of a large amplitude drift-Alfven wave. Surprisingly, the measured speeds were an order of magnitude lower than predicted by standard fluid theory, yet the flow pattern was consistent with the fluid theory. A new model, based on the connection between stochasticity and bulk behavior, is presented which gives insights into the cause of this behavior. It is shown that when particle motion is stochastic, invariant sets of a 'Poincaré map' define a flat-topped particle distribution function consistent with both the electromagnetic field driving the Vlasov equation and the fine-scale single particle dynamics. The approach is described for the general case and explored for a slab model of the observed drift wave

    Behavioural simulation of biological neuron systems using VHDL and VHDL-AMS

    No full text
    The investigation of neuron structures is an incredibly difficult and complex task that yields relatively low rewards in terms of information from biological forms (either animals or tissue). The structures and connectivity of even the simplest invertebrates are almost impossible to establish with standard laboratory techniques, and even when this is possible it is generally time consuming, complex and expensive. Recent work has shown how a simplified behavioural approach to modelling neurons can allow “virtual” experiments to be carried out that map the behaviour of a simulated structure onto a hypothetical biological one, with correlation of behaviour rather than underlying connectivity. The problems with such approaches are numerous. The first is the difficulty of simulating realistic aggregates efficiently, the second is making sense of the results and finally, it would be helpful to have an implementation that could be synthesised to hardware for acceleration. In this paper we present a VHDL implementation of Neuron models that allow large aggregates to be simulated. The models are demonstrated using a system level VHDL and VHDL-AMS model of the C. Elegans locomotory system

    Repeated exercise stress impairs volitional but not magnetically evoked electromechanical delay of the knee flexors

    Get PDF
    The effects of serial episodes of fatigue and recovery on volitional and magnetically evoked neuromuscular performance of the knee flexors were assessed in twenty female soccer players during: (i) an intervention comprising 4x35s maximal static exercise; (ii) a control condition. Volitional peak force (PFV) was impaired progressively (-16 % vs. baseline: 235.3±54.7 to 198.1±38.5 N) by the fatiguing exercise and recovered to within -97 % of baseline values following six-minutes of rest. Evoked peak twitch force (PTFE) was diminished subsequent to the fourth episode of exercise (23.3 %: 21.4±13.8 vs. 16.4±14.6 N) and remained impaired at this level throughout the recovery. Impairment of volitional electromechanical delay performance (EMDV) following the first episode of exercise (25.5 % :55.3±11.9 vs. 69.5±24.5 ms) contrasted with concurrent improvement (10.0 %: 24.5±4.7 vs. 22.1±5.0 ms) in evoked electromechanical delay (EMDE) (p <0.05) and this increased disparity between EMDE and EMDV remained during subsequent periods of intervention and recovery. The fatiguing exercise provoked substantial impairments to volitional strength and EMDV that showed differential patterns of recovery. However, improved EMDE performance might identify a dormant capability for optimal muscle responses during acute stressful exercise and an improved capacity to maintain dynamic joint stabilty during critical episodes of loading

    Scene simulation for passive IR systems

    Get PDF
    The development of large mosaic detector arrays will allow for the construction of staring long wave infrared (LWIR) sensors which can observe large fields of view instantaneously and continuously. In order to evaluate and exercise these new systems, it will be necessary to provide simulated scenes of many moving targets against an infrared clutter background. Researchers are currently developing a projector/screen system. This system is comprised of a mechanical scanner, a diffuse screen, and a miniature blackbody. A prototype of the mechanical scanner, which is comprised of four independently driven scanners, has been designed, fabricated, and evaluated under room and cryogenic vacuum conditions. A large diffuse screen has been constructed and tested for structural integrity under cryogenic/vacuum thermal cycling. Construction techniques have been developed for the fabrication of miniature high-temperature blackbody sources. Finally, a concept has been developed to use this miniature blackbody to produce a spectrally tailorable source

    Characterization of a spheromak plasma gun: The effect of refractory electrode coatings

    Get PDF
    In order to investigate the proposition that high-Z impurities are responsible for the anomalously short lifetime of the Caltech spheromak, the center electrode of the spheromak plasma gun has been coated with a variety of metals (bare steel, copper, nickel, chromium, rhodium, and tungsten). Visible light (230–890 nm) emitted directly from the plasma in the gun breech was monitored for each of the coated electrodes. Plasma density and temperature and spheromak lifetime were compared for each electrode. Results indicate little difference in gun performance or macroscopic plasma parameters. The chromium and tungsten electrodes performed marginally better in that a previously reported helicity injection effect [Phys. Rev. Lett. 64, 2144 (1990)] is only observed in discharges using these electrode coatings. There are subtle differences in the detailed line emission spectra from the different electrodes, but the spectra are remarkably similar. The fact that (1) contrary to expectations, attempts to reduce high-Z impurities had only marginal effect on the spheromak lifetime coupled with (2) an estimate of Zeff<2 based on a 0-D model suggests that it is not impurities but some other mechanism that limits the lifetime of small, cold spheromaks. We will discuss the general characteristics of the spheromak gun as well as effects due to the coatings

    Electronic compensation for reflector surface distortion to improve radiation pattern characteristics of antennas

    Get PDF
    A simple procedure is described for determining the excitation coefficients of an array feed which compensates for the surface distortion of a reflector antenna to improve the radiation pattern in such a way as to approximate the performance of the undistorted antenna. A computer simulation for a practical feed array is presented as an example of compensation for the distortion of an actual antenna
    • …
    corecore