371 research outputs found
An improved linear ion trap physics package
This article describes an improvement in the architecture of the physics package used in the Linear Ion Trap (LIT)-based frequency standard recently developed at JPL. This new design is based on the observation that ions can be moved along the axis of an LIT by applied dc voltages. The state selection and interrogation region can be separated from the more critical microwave resonance region where the multiplied local oscillator signal is compared with the stable atomic transition. This separation relaxes many of the design constraints of the present units. Improvements include increased frequency stability and a substantial reduction in size, mass, and cost of the final frequency standard
Spatial Variations of Fundamental Constants
We show that observational limits on the possible time variation of constants
of Nature are significantly affected by allowing for both space and time
variation. Bekenstein's generalisation of Maxwell's equations to allow for
cosmological variation of is investigated in a universe containing
spherically symmetric inhomogeneities. The time variation of is
determined by the local matter density and hence limits obtained in
high-density geophysical enviroments are far more constraining than those
obtained at high redshift. This new feature is expected to be a property of a
wide class of theories for the variation of constants.Comment: 4 page
Extended linear ion trap frequency standard apparatus
A linear ion trap for frequency standard applications is provided with a plurality of trapping rods equally spaced and applied quadruple rf voltages for radial confinement of atomic ions and biased level pins at each end for axial confinement of the ions. The trapping rods are divided into two linear ion trap regions by a gap in each rod in a common radial plane to provide dc discontinuity, thus dc isolating one region from the other. A first region for ion-loading and preparation fluorescence is biased with a dc voltage to transport ions into a second region for resonance frequency comparison with a local oscillator derived frequency while the second region is held at zero voltage. The dc bias voltage of the regions is reversed for transporting the ions back into the first region for fluorescence measurement. The dual mode cycle is repeated continuously for comparison and feedback control of the local oscillator derived frequency. Only the second region requires magnetic shielding for the resonance function which is sensitive to any ambient magnetic fields
New ion trap for atomic frequency standard applications
A novel linear ion trap that permits storage of a large number of ions with reduced susceptibility to the second-order Doppler effect caused by the radio frequency (RF) confining fields has been designed and built. This new trap should store about 20 times the number of ions a conventional RF trap stores with no corresponding increase in second-order Doppler shift from the confining field. In addition, the sensitivity of this shift to trapping parameters, i.e., RF voltage, RF frequency, and trap size, is greatly reduced
Atomic frequency standards for ultra-high-frequency stability
The general features of the Hg-199(+) trapped-ion frequency standard are outlined and compared to other atomic frequency standards, especially the hydrogen maser. The points discussed are those which make the trapped Hg-199(+) standard attractive: high line Q, reduced sensitivity to external magnetic fields, and simplicity of state selection, among others
Simple analytic potentials for linear ion traps
A simple analytical model was developed for the electric and ponderomotive (trapping) potentials in linear ion traps. This model was used to calculate the required voltage drive to a mercury trap, and the result compares well with experiments. The model gives a detailed picture of the geometric shape of the trapping potenital and allows an accurate calculation of the well depth. The simplicity of the model allowed an investigation of related, more exotic trap designs which may have advantages in light-collection efficiency
The JPL trapped mercury ion frequency standard
In order to provide frequency standards for the Deep Space Network (DSN) which are more stable than present-day hydrogen masers, a research task was established under the Advanced Systems Program of the TDA to develop a Hg-199(+) trapped ion frequency standard. The first closed-loop operation of this kind is described. Mercury-199 ions are confined in an RF trap and are state-selected through the use of optical pumping with 194 nm UV light from a Hg-202 discharge lamp. Absorption of microwave radiation at the hyperfine frequency (40.5 GHz) is signaled by atomic fluorescence of the UV light. The frequency of a 40.5 GHz oscillator is locked to a 1.6 Hz wide atomic absorption line of the trapped ions. The measured Allan variance of this locked oscillator is currently gamma sub y (pi) = 4.4 x 10 to the minus 12th/square root of pi for 20 is less than pi is less than 320 seconds, which is better stability than the best commercial cesium standards by almost a factor of 2. This initial result was achieved without magnetic shielding and without regulation of ion number
Multi-Pass Quadrupole Mass Analyzer
Analysis of the composition of planetary atmospheres is one of the most important and fundamental measurements in planetary robotic exploration. Quadrupole mass analyzers (QMAs) are the primary tool used to execute these investigations, but reductions in size of these instruments has sacrificed mass resolving power so that the best present-day QMA devices are still large, expensive, and do not deliver performance of laboratory instruments. An ultra-high-resolution QMA was developed to resolve N2 +/CO+ by trapping ions in a linear trap quadrupole filter. Because N2 and CO are resolved, gas chromatography columns used to separate species before analysis are eliminated, greatly simplifying gas analysis instrumentation. For highest performance, the ion trap mode is used. High-resolution (or narrow-band) mass selection is carried out in the central region, but near the DC electrodes at each end, RF/DC field settings are adjusted to allow broadband ion passage. This is to prevent ion loss during ion reflection at each end. Ions are created inside the trap so that low-energy particles are selected by low-voltage settings on the end electrodes. This is beneficial to good mass resolution since low-energy particles traverse many cycles of the RF filtering fields. Through Monte Carlo simulations, it is shown that ions are reflected at each end many tens of times, each time being sent back through the central section of the quadrupole where ultrahigh mass filtering is carried out. An analyzer was produced with electrical length orders of magnitude longer than its physical length. Since the selector fields are sized as in conventional devices, the loss of sensitivity inherent in miniaturizing quadrupole instruments is avoided. The no-loss, multi-pass QMA architecture will improve mass resolution of planetary QMA instruments while reducing demands on the RF electronics for high-voltage/high-frequency production since ion transit time is no longer limited to a single pass. The QMA-based instrument will thus give way to substantial reductions of the mass of flight instruments
Sexual negotiation in the AIDS era: negotiated safety revisited
Objective: To test the safety of the 'negotiated safety' strategy - the strategy of dispensing with condoms within HIV-seronegative concordant regular sexual relationships under certain conditions. Method: Data from a recently recruited cohort of homosexually active men (Sydney Men and Sexual Health cohort, n = 1037) are used to revisit negotiated safety. The men were surveyed using a structured questionnaire and questions addressing their sexual relationships and practice, their own and their regular partner's serostatus, agreements entered into by the men concerning sexual practice within and outside their regular relationship, and contextual and demographic variables. Results: The findings indicate that a significant number of men used negotiated safety as an HIV prevention strategy. In the 6 months prior to interview, of the 181 men in seroconcordant HIV-negative regular relationships, 62% had engaged in unprotected anal intercourse within their relationship, and 91% (165 men) had not engaged in unprotected anal intercourse outside their relationship. Of these 165 men, 82% had negotiated agreements about sex outside their relationship. The safety of negotiation was dependent not only on seroconcordance but also on the presence of an agreement; 82% of the men who had not engaged in unprotected anal intercourse outside their regular relationship had entered into an agreement with their partner, whereas only 56% of those who had engaged in unprotected anal intercourse had an agreement. The safety of negotiation was also related to the nature of the safety agreement reached between the men and on the acceptability of condoms. Agreements between HIV-negative seroconcordant regular partners prohibiting anal intercourse with casual partners or any form of sex with a casual partner were typically complied with, and men who had such negotiated agreements were at low risk of HIV infection. Conclusions: The adoption of the strategy of negotiated safety among men in HIV-seronegative regular relationships may help such men sustain the safety of their sexual practice
An ion ring in a linear multipole trap for optical frequency metrology
A ring crystal of ions trapped in a linear multipole trap is studied as a
basis for an optical frequency standard. The equilibrium conditions and cooling
possibilities are discussed through an analytical model and molecular dynamics
simulations. A configuration which reduces the frequency sensitivity to the
fluctuations of the number of trapped ions is proposed. The systematic shifts
for the electric quadrupole transition of calcium ions are evaluated for this
ring configuration. This study shows that a ring of 10 or 20 ions allows to
reach a short term stability better than for a single ion without introducing
limiting long term fluctuations
- …