129 research outputs found

    Biphasic constitutive laws for biological interface evolution

    Full text link

    Curing Kinetics and Mechanical Properties of a Composite Hydrogel for the Replacement of the Nucleus Pulposus

    Get PDF
    A polymer material system has been developed to propose an injectable, UV and in situ curable hydrogel with properties similar to the native nucleus pulposus of intervertebral disc. Neat hydrogels based on Tween® 20 trimethacrylates (T3) and N-vinyl-2-pyrrolidone (NVP) and composite hydrogels of same composition reinforced by nano-fibrillated cellulose were synthesized with different T3 concentrations and their curing kinetics was investigated by photorheology using UV light. The T3 concentration has an influence on the time of curing and final shear stiffness of the material. NFC does not alter the time of curing but increases the final mechanical performance of the hydrogels for a same chemical composition. Hydrogel samples, neat and composite, were then tested in unconfined compression at different hydration stages and in confined compression and their elastic modulus was determined. The amount of fluid present in the network is mostly responsible for the mechanical properties and NFC fibres proved to be an efficient reinforcement. The elastic modulus ranged from 0.02 to 8 MPa. Biocompatibility studies showed that cells are confluent at 90% and do not show any morphology change when in contact with the hydrogel. The present hydrogel can therefore be considered for NP replacement

    Tailoring swelling to control softening mechanisms during cyclic loading of PEG/cellulose hydrogel composites

    Get PDF
    One of the novel approaches for discogenic lower back pain treatment is to permanently replace the core of the intervertebral disc, so-called Nucleus Pulposus, through minimally invasive surgery. Recently, we have proposed Poly(Ethylene Glycol) Dimethacrylate (PEGDM) hydrogel reinforced with Nano-Fibrillated Cellulose (NFC) fibers as an appropriate replacement material. In addition to the tuneable properties, that mimic those of the native tissue, the surgeon can directly inject it into the degenerated disc and cure it in situ via UV-light irradiation. However, in view of clinical applications, the reliability of the proposed material has to be tested under long-term fatigue loading. To that end, the present study focused on the characterization of the fatigue behavior of the composite hydrogel and investigated the governing physical phenomena behind it. The results show that composite PEGDM-NFC hydrogel withstands the 10 million compression cycles at physiological condition. However, its modulus decreases by almost 10% in the first cycle and then remains constant, while cyclic loading does not affect the neat PEGDM hydrogel. The observed softening behavior has similar characteristics of the Mullins effect. It is shown that the reduction of modulus is due to the gradual change of NFC network, which is highly stretched in the swollen state. Moreover, the swelling degree of the matrix is correlated to the extent of softening during cyclic loading. Consequently, softening can be minimized by lowering the swelling of the composite hydrogel

    Gene expression analysis of osteoblastic cells contacted by orthopedic implant particles

    Get PDF
    Particles generated from orthopedic implants through years of wear play an essential role in the aseptic loosening of a prosthesis. We have investigated the biocompatibility of these orthopedic particles on different osteoblast-like cells representative of different stages of osteoblast maturation. We found the particles induced a caspase-dependent apoptosis of osteoblasts, with less mature osteoblasts being the most susceptible. An analysis of gene expression was performed on the less mature osteoblasts, which were in contact with the particles. We found that the particles had a profound impact on genes that code for inflammatory cytokines and genes involved in controlling the nuclear architecture. Results from this study suggest that the peri-implant osteolysis after a total joint replacement can be due in part to a decrease of bone formation and not solely to an overstimulation of bone resorption as is generally proposed. Development of new drugs that promote normal bone formation and osteoblast survival would possibly control peri-implant osteolysis, resulting in a better prognosis for patients with orthopedic implants

    Mechanical interaction between cells and fluid for bone tissue engineering scaffold: modulation of the interfacial shear stress

    Get PDF
    An analytical model of the fluid/cell mechanical interaction was developed. The interfacial shear stress, due to the coupling between the fluid and the cell deformation, was characterized by a new dimensionless number . For above a critical value, the fluid/cell interaction had a damping effect on the interfacial shear stress. Conversely, for below this critical value, interfacial shear stress was amplified. As illustration, the role of the dynamic fluid/cell mechanical coupling was studied in a specific biological situation involving cells seeded in a bone scaffold. For the particular bone scaffold chosen, the dimensionless number Nfs was higher than the critical value. In this case, the dynamic shear stress at the fluid/cell interface is damped for increasing excitation frequency. Interestingly, this damping effect is correlated to the pore diameter of the scaffold, furnishing thus target values in the design of the scaffold. Correspondingly, an efficient cell stimulation might be achieved with a scaffold of pore size larger than 300 ÎĽm as no dynamic damping effect is likely to take place. The analytical model proposed in this study, while being a simplification of a fluid/cell mechanical interaction, brings complementary insights to numerical studies by analyzing the effect of different physical parameters

    The cytotoxic effect of titanium particles phagocytosed by osteoblasts

    Get PDF
    The cytotoxic effect of different concentrations of titanium particles on osteoblasts was studied in vitro. It was found that the viability of the osteoblasts was inversely proportional to the particle concentration. Phagocytosis of particles by the osteoblasts was evident and was demonstrated to be responsible for cell necrosis. Moreover, during and after phagocytosis, the osteoblasts released products that were cytotoxic for other osteoblasts, as established with a conditioned medium assay. The titanium particles thus had both a direct and an indirect effect on osteoblast viability. It also was observed that the titanium particles induced a process of programmed cell death (apoptosis) when co-cultured with osteoblasts. The results of this study suggest that not only is the amount of wear debris generated important, but the local accumulation of the debris also may have a significant impact on bone cell function

    How plate positioning impacts the biomechanics of the open wedge tibial osteotomy; a finite element analysis

    Get PDF
    A numerical model of the medial open wedge tibial osteotomy based on the finite element method was developed. Two plate positions were tested numerically. In a configuration, (a), the plate was fixed in a medial position and (b) in an anteromedial position. The simulation took into account soft tissues preload, muscular tonus and maximal gait load.The maximal stresses observed in the four structural elements (bone, plate, wedge, screws) of an osteotomy with plate in medial position were substantially higher (1.13-2.8 times more) than those observed in osteotomy with an anteromedial plate configuration. An important increase (1.71 times more) of the relative micromotions between the wedge and the bone was also observed. In order to avoid formation of fibrous tissue at the bone wedge interface, the osteotomy should be loaded under 18.8% (approximately 50 kg) of the normal gait load until the osteotomy interfaces union is achieved
    • …
    corecore