828 research outputs found

    Criticality in Dynamic Arrest: Correspondence between Glasses and Traffic

    Full text link
    Dynamic arrest is a general phenomenon across a wide range of dynamic systems, but the universality of dynamic arrest phenomena remains unclear. We relate the emergence of traffic jams in a simple traffic flow model to the dynamic slow down in kinetically constrained models for glasses. In kinetically constrained models, the formation of glass becomes a true (singular) phase transition in the limit T0T\to 0. Similarly, using the Nagel-Schreckenberg model to simulate traffic flow, we show that the emergence of jammed traffic acquires the signature of a sharp transition in the deterministic limit \pp\to 1, corresponding to overcautious driving. We identify a true dynamical critical point marking the onset of coexistence between free flowing and jammed traffic, and demonstrate its analogy to the kinetically constrained glass models. We find diverging correlations analogous to those at a critical point of thermodynamic phase transitions.Comment: 4 pages, 4 figure

    Hotspot mixing:A framework for heterodyne mixing in superconducting hot-electron bolometers

    Get PDF
    We propose a framework to interpret heterodyne mixing in superconducting hot-electron bolometers. The physical conversion process of the mixer is the result of an electronic hotspot, of which the length, and consequently the resistance, oscillates at the intermediate frequency. On the basis of this concept, we calculate the (un)pumped current–voltage relation, the dc voltage responsivity, and the mixer conversion efficiency

    Unexpected Magnetism of Small Silver Clusters

    Get PDF
    The ground-state electronic, structural, and magnetic properties of small silver clusters, Agn_n (2\len\le22), have been studied using a linear combination of atomic Gaussian-type orbitals within the density functional theory. The results show that the silver atoms, which are diamagnetic in bulk environment, can be magnetic when they are grouped together in clusters. The Ag13_{13} cluster with icosahedral symmetry has the highest magnetic moment per atom among the studied silver clusters. The cluster symmetry and the reduced coordination number specific of small clusters reveal as a fundamental factor for the onset of the magnetism.Comment: 4 pages, 4 figure

    Clinical performance of a novel textile interface for neonatal chest electrical impedance tomography

    Get PDF
    Objective: Critically ill neonates and infants might particularly benefit from continuous chest electrical impedance tomography (EIT) monitoring at the bedside. In this study a textile 32-electrode interface for neonatal EIT examination has been developed and tested to validate its clinical performance. The objectives were to assess ease of use in a clinical setting, stability of contact impedance at the electrode–skin interface and possible adverse effects. Approach: Thirty preterm infants (gestational age: 30.3 ± 3.9 week (mean ± SD), postnatal age: 13.8 ± 28.2 d, body weight at inclusion: 1727 ± 869 g) were included in this multicentre study. The electrode–skin contact impedances were measured continuously for up to 3 d and analysed during the initial 20-min phase after fastening the belt and during a 10 h measurement interval without any clinical interventions. The skin condition was assessed by attending clinicians. Main results: Our findings imply that the textile electrode interface is suitable for long-term neonatal chest EIT imaging. It does not cause any distress for the preterm infants or discomfort. Stable contact impedance of about 300 Ohm was observed immediately after fastening the electrode belt and during the subsequent 20 min period. A slight increase in contact impedance was observed over time. Tidal variation of contact impedance was less than 5 Ohm. Significance: The availability of a textile 32-electrode belt for neonatal EIT imaging with simple, fast, accurate and reproducible placement on the chest strengthens the potential of EIT to be used for regional lung monitoring in critically ill neonates and infants

    Introducing willingness-to-pay for noise changes into transport appraisal: an application of benefit transfer.

    Get PDF
    Numerous research studies have elicited willingness-to-pay values for transport-related noise, however, in many industrialised countries including the UK, noise costs and benefits are still not incorporated into appraisals for most transport projects and policy changes (Odgaard et al, 2005; Grant-Muller et al, 2001). This paper describes the actions recently taken in the UK to address this issue, comprising: primary research based on the city of Birmingham; an international review of willingness-to-pay evidence; development of values using benefit transfers over time and locations; and integration with appraisal methods. Amongst the main findings are: that the willingness-to-pay estimates derived for the UK are broadly comparable with those used in appraisal elsewhere in Europe; that there is a case for a lower threshold at 1 45dB(A)Leq,18hr1 rather than the more conventional 55dB(A); and that values per dB(A) increase with the noise level above this threshold. There are significant issues over the valuation of rail versus road noise, the neglect of non-residential noise and the valuation of high noise levels in different countries. Conclusions are drawn regarding the feasibility of noise valuation based on benefit transfers in the UK and elsewhere, and future research needs in this field are discussed

    The Influence of an Adsorbate Layer on Adatom Diffusion and Island Nucleation: Fe on Si(111)-√3 x √3-Au

    Get PDF
    Using scanning tunneling microscopy, the influence of a thin Au layer on the diffusion of Fe adatoms and the subsequent island nucleation on a Si(111) surface is investigated. The adsorbate induces thestructure that increases the surface mobility of subsequently deposited Fe atoms, resulting in the formation well-defined nanoclusters. Surprisingly, the domain walls—inherent to the reconstruction—do not influence the surface diffusion, which demonstrates that the passivation is of much more importance for the self-assembly than the surface corrugation. Using the decoupling of the diffusion and nucleationonthe surface and the reactionwiththe surface and conventional nucleation theory, the activation energy for surface diffusionEd = 0.61 eV and the critical cluster sizei = 3 are determined, which reveal the microscopic details of the diffusion and nucleation processes

    Totally asymmetric simple exclusion process simulations of molecular motor transport on random networks with asymmetric exit rates

    Get PDF
    Using the totally asymmetric simple-exclusion-process and mean-field transport theory, we investigate the transport in closed random networks with simple crossing topology—two incoming, two outgoing segments, as a model for molecular motor motion along biopolymer networks. Inspired by in vitro observation of molecular motor motion, we model the motor behavior at the intersections by introducing different exit rates for the two outgoing segments. Our simulations of this simple network reveal surprisingly rich behavior of the transport current with respect to the global density and exit rate ratio. For asymmetric exit rates, we find a broad current plateau at intermediate motor densities resulting from the competition of two subnetwork populations. This current plateau leads to stabilization of transport properties within such networks

    Optimized breath detection algorithm in electrical impedance tomography

    Get PDF
    This paper defines a method for optimizing the breath delineation algorithms used in Electrical Impedance Tomography (EIT). In lung EIT the identification of the breath phases is central for generating tidal impedance variation images, subsequent data analysis and clinical evaluation. The optimisation of these algorithms is particularly important in neonatal care since the existing breath detectors developed for adults may give insufficient reliability in neonates due to their very irregular breathing pattern. Our approach is generic in the sense that it relies on the definition of a gold standard and the associated definition of detector sensitivity and specificity, an optimisation criterion and a set of detector parameters to be investigated. The gold standard has been defined by 11 clinicians with previous experience with EIT and the performance of our approach is described and validated using a neonatal EIT dataset acquired within the EU-funded CRADL project. Three different algorithms are proposed that are improving the breath detector performance by adding conditions on 1) maximum tidal breath rate obtained from zero-crossings of the EIT breathing signal, 2) minimum tidal impedance amplitude and 3) minimum tidal breath rate obtained from Time-Frequency (TF) analysis. As a baseline the zero crossing algorithm has been used with some default parameters based on the Swisstom EIT device. Based on the gold standard, the most crucial parameters of the proposed algorithms are optimised by using a simple exhaustive search and a weighted metric defined in connection with the Receiver Operating Characterics (ROC). This provides a practical way to achieve any desirable trade-off between the sensitivity and the specificity of the detectors. [Abstract copyright: © 2018 Institute of Physics and Engineering in Medicine.
    corecore