43 research outputs found

    Near real-time input to a propagation model for nowcasting of HF communications with aircraft on polar routes

    Get PDF
    There is a need for improved techniques for nowcasting and forecasting (over several hours) HF propagation at northerly latitudes to support airlines operating over the increasingly popular trans-polar routes. In this paper the assimilation of real-time measurements into a propagation model developed by the authors is described, including ionosonde measurements and Total Electron Content (TEC) measurements to define the main parameters of the ionosphere. The effects of D-region absorption in the polar cap and auroral regions are integrated with the model through satellite measurements of the flux of energetic solar protons (>1 MeV) and the X-ray flux in the 0.1-0.8 nm band, and ground-based magnetometer measurements which form the Kp and Dst indices of geomagnetic activity. The model incorporates various features (e.g. convecting patches of enhanced plasma density) of the polar ionosphere that are, in particular, responsible for off-great circle propagation and lead to propagation at times and frequencies not expected from on-great circle propagation alone. The model development is supported by the collection of HF propagation measurements over several paths within the polar cap, crossing the auroral oval, and along the mid-latitude trough

    GEANT4 : a simulation toolkit

    Get PDF
    Abstract Geant4 is a toolkit for simulating the passage of particles through matter. It includes a complete range of functionality including tracking, geometry, physics models and hits. The physics processes offered cover a comprehensive range, including electromagnetic, hadronic and optical processes, a large set of long-lived particles, materials and elements, over a wide energy range starting, in some cases, from 250 eV and extending in others to the TeV energy range. It has been designed and constructed to expose the physics models utilised, to handle complex geometries, and to enable its easy adaptation for optimal use in different sets of applications. The toolkit is the result of a worldwide collaboration of physicists and software engineers. It has been created exploiting software engineering and object-oriented technology and implemented in the C++ programming language. It has been used in applications in particle physics, nuclear physics, accelerator design, space engineering and medical physics. PACS: 07.05.Tp; 13; 2

    Distinct effects of rectum delineation methods in 3D-confromal vs. IMRT treatment planning of prostate cancer

    Get PDF
    BACKGROUND: The dose distribution to the rectum, delineated as solid organ, rectal wall and rectal surface, in 3D conformal (3D-CRT) and intensity-modulated radiotherapy treatment (IMRT) planning for localized prostate cancer was evaluated. MATERIALS AND METHODS: In a retrospective planning study 3-field, 4-field and IMRT treatment plans were analyzed for ten patients with localized prostate cancer. The dose to the rectum was evaluated based on dose-volume histograms of 1) the entire rectal volume (DVH) 2) manually delineated rectal wall (DWH) 3) rectal wall with 3 mm wall thickness (DWH(3)) 4) and the rectal surface (DSH). The influence of the rectal filling and of the seminal vesicles' anatomy on these dose parameters was investigated. A literature review of the dose-volume relationship for late rectal toxicity was conducted. RESULTS: In 3D-CRT (3-field and 4-field) the dose parameters differed most in the mid-dose region: the DWH showed significantly lower doses to the rectum (8.7% ± 4.2%) compared to the DWH(3 )and the DSH. In IMRT the differences between dose parameters were larger in comparison with 3D-CRT. Differences were statistically significant between DVH and all other dose parameters and between DWH and DSH. Mean doses were increased by 23.6% ± 8.7% in the DSH compared to the DVH in the mid-dose region. Furthermore, both the rectal filling and the anatomy of the seminal vesicles influenced the relationship between the dose parameters: a significant correlation of the difference between DVH and DWH and the rectal volume was seen in IMRT treatment. DISCUSSION: The method of delineating the rectum significantly influenced the dose representation in the dose-volume histogram. This effect was pronounced in IMRT treatment planning compared to 3D-CRT. For integration of dose-volume parameters from the literature into clinical practice these results have to be considered

    GEANT4--a simulation toolkikt

    Get PDF
    Geant4 is a toolkit for simulating the passage of particles through matter. It includes a complete range of functionality including tracking, geometry, physics models and hits. The physics processes offered cover a comprehensive range, including electromagnetic, hadronic and optical processes, a large set of long-lived particles, materials and elements, over a wide energy range starting, in some cases, from 250 eV and extending in others to the TeV energy range. It has been designed and constructed to expose the physics models utilised, to handle complex geometries, and to enable its easy adaptation for optimal use in different sets of applications. The toolkit is the result of a worldwide collaboration of physicists and software engineers. It has been created exploiting software engineering and object-oriented technology and implemented in the C++ programming language. It has been used in applications in particle physics, nuclear physics, accelerator design, space engineering and medical physics

    Potential presence of trihalomethanes in water intended for human consumption

    No full text
    Since the 1970s it is well known that, though water for human consumption must generally be disinfected before being distributed along the network, the use of chemicals results in the formation of many different Disinfeection By-Products (DBPs). In the case of chlorine-based disinfectants, trihalomethanes (THMs) are the most widely studied: the present work first compares some national and international regulations on this subject, then, in the experimental part, compares the results of a test carried out by disinfecting water of different origin collected in three different Italian regions with different amounts of chlorine. Samples were stored at ambient temperature for seven days, then the determination of THMs was carrried out by Purge and Trap extraction coupled with gas cromatography with Electron Capture Detection (ECD). The result obtained are finally compared and discussed

    Hamming clustering techniques for the identification of prognostic indices in patients with advanced head and neck cancer treated with radiation therapy.

    No full text
    The aim of the study is to demonstrate the usefulness of a new, non-linear classifier method, called Hamming clustering (HC) in selecting prognostic variables affecting overall survival in patients with head and neck cancer. In particular, the aim is to identify whether tumour proliferation parameters can be predictive factors of response in a set of 115 patients that receive either alternating chemo-radiotherapy or accelerated or conventional radiotherapy. HC is able to generate a set of understandable rules underlying the study objective; it can also select a subset of input variables that represent good prognostic factors. HC has been compared with other standard classifiers, providing better results in terms of classification accuracy. In particular, HC obtains the best accuracy of 74.8% (sensitivity of 51.1% and specificity of 91.2%) about survival. The rules found show that, besides the classical, well-known variables concerning the tumour dimension and the involved lymphonodes, some biological parameters, such as DNA ploidy, are also useful as predictive factors
    corecore