170 research outputs found

    Nucleic acid vaccine encoding gD2 protects mice from herpes simplex virus type 2 disease.

    Get PDF
    Journal ArticleNucleic acid vaccinations with plasmids pWW65, containing the sequence for herpes simplex type 2 (HSV-2) gD2, and pRSVnt, lacking the gD sequence, were studied. Groups of mice were immunized with pWW65 alone, pWW65 plus 1,25-dihydroxyvitamin-D3 (D3), or pRSVnt. Clinical disease (vaginitis), serum and vaginal washing antibody levels, and vaginal washing virus titers were measured intravaginal HSV-2 challenge. No animals (0/10) in the pWW65 + D3 group, 6/10 animals in the pWW65 group, and 10/10 animals in the pRSVnt group developed severe disease by postchallenge day 13 (P<.001, P=.04 vs. pRSVnt). Virus titers in vaginal washings were significantly reduced in the pWW65 and pWW65+D3 groups versus the pRSVnt group (P<.001). Increasing levels of serum anti-gD2 antibodies were measured 2 and 6 days after challenge among animals in the pWW65 and pWW65+D3 groups but not among animals in the pRSVnt group. Vaccinations with a plasmid containing the gD2 gene are immunogenic and provide some protection from HSV-2-induced disease

    Use of the Natural Circulation Flow Map for Natural Circulation Systems Evaluation

    Get PDF
    The aim of this paper is to collect and resume the work done to build and develop, at the University of Pisa, an engineering tool related to the natural circulation. After a brief description of the different loop flow regimes in single phase and two phase, the derivation of a suitable tool to judge the NC performance in a generic system is presented. Finally, an extensive comparison among the NC performance of various nuclear power plants having different design is done to show a practical application of the NC flow map

    Effect of the Ambient Temperature on the Start-Up of a Multi-Evaporator Loop Thermosyphon

    Get PDF
    Two-phase heat transfer devices are becoming fairly ubiquitous; the capability to transport heat at high rates over appreciable distances, without any external pumping device, the low cost, durability and relatively simpler modeling/design process, make this technology very attractive for many thermal management applications. Indeed, such devices have been investigated in plenty of fields such as: nuclear plants, energy systems, solar heat recovery, air conditioning, electronic cooling in avionics and in railway traction. As a consequence, they can operate under different environmental conditions that can affect their behavior. Nevertheless, it is difficult to find in literature something related to the effect of the ambient temperature on the thermal performance of such devices. The actual temperature, varying the thermo-fluid properties of the fluid inside the device, the condensation and the evaporation phenomena, could be an important parameter that can affect the performance. In this work a Multi-Evaporator loop thermosyphon is tested at different ambient temperatures, ranging from -20 °C up to 30 °C. The start-up behavior, as well as the thermal performance, are analyzed by means of temperature and pressure measurements and fluid flow visualization

    Seasonal moisture sources and the isotopic composition of precipitation, rivers, and carbonates across the Andes at 32º-35.5°S

    Get PDF
    Constraining the influence of different moisture sources across the flanks of mountain ranges is important for understanding tectonic, geomorphic, and paleoclimate problems at geologic timescales, as well as evaluating climate change and water resources on human time scales. The stable isotope compositions of stream waters and precipitation are an ideal tool for this task. This study reports the results of a 2 year monthly precipitation sampling campaign on the eastern flank of the Andes in the Mendoza Province of Argentina, which began in September 2008. A total of 104 precipitation samples spanning some 2500 m of relief from nine sites were analyzed for δD and δ18O. In addition, 81 samples from Andean rivers collected on both sides of the range in 2002 and 2007 were analyzed. We employ a Rayleigh isotope fractionation modeling approach to explore spatial and temporal variations in precipitation and river water compositions. The results indicate that precipitation on the eastern slopes of the Andes at ~33°S, at elevations above 2 km, is largely derived from a westerly, Pacific-source component and a mixture of easterly and westerly sources below 2 km. Further south at ~35°S, river water compositions exhibit a strong winter influence. At 33°S, rivers have an isotopic minimum of ~ −18? across the core of the range, which has an average elevation of 4000 m, and are topographically offset from similar isotopic values of precipitation by +1000 m. Comparison of precipitation and river water data with temperature-corrected δ18O estimates from pedogenic carbonates illustrates that carbonates capture the range of variability observed in modern precipitation and Rayleigh fractionation models.Fil: Hoke, Gregory D.. Syracuse University. Department of Earth Sciences; Estados UnidosFil: Aranibar, Julieta Nelida. Consejo Nacional de Investigaciones Científicas y Técnicas. Científico Tecnológico Mendoza. Instituto Argentino de Nivología, Glaciología y Ciencias Ambientales; Argentina. Universidad Nacional de Cuyo. Facultad de Ciencias Exactas y Naturales; ArgentinaFil: Viale, Maximiliano. Universidad de Chile. Departamento de Geofísica. Facultad de Ciencias Físicas y Matemáticas; Chile. Consejo Nacional de Investigaciones Científicas y Técnicas. Científico Tecnológico Mendoza. Instituto Argentino de Nivología, Glaciología y Ciencias Ambientales; ArgentinaFil: Araneo, Diego Christian. Consejo Nacional de Investigaciones Científicas y Técnicas. Científico Tecnológico Mendoza. Instituto Argentino de Nivología, Glaciología y Ciencias Ambientales; ArgentinaFil: Llano, Carina. Museo de Historia Natural de San Rafael. Departamento de Antropología; Argentin

    Fluid-flow pressure measurements and thermo-fluid characterization of a single loop two-phase passive heat transfer device

    Get PDF
    Abstract A Novel Single Loop Pulsating Heat Pipe (SLPHP), with an inner diameter of 2 mm, filled up with two working fluids (Ethanol and FC-72, Filling Ratio of 60%), is tested in Bottom Heated mode varying the heating power and the orientation. The static confinement diameter for Ethanol and FC-72, respectively 3.4 mm and 1.7mm, is above and slightly under the inner diameter of the tube. This is important for a better understanding of the working principle of the device very close to the limit between the Loop Thermosyphon and Pulsating Heat Pipe working modes. With respect to previous SLPHP experiments found in the literature, such device is designed with two transparent inserts mounted between the evaporator and the condenser allowing direct fluid flow visualization. Two highly accurate pressure transducers permit local pressure measurements just at the edges of one of the transparent inserts. Additionally, three heating elements are controlled independently, so as to vary the heating distribution at the evaporator. It is found that peculiar heating distributions promote the slug/plug flow motion in a preferential direction, increasing the device overall performance. Pressure measurements point out that the pressure drop between the evaporator and the condenser are related to the flow pattern. Furthermore, at high heat inputs, the flow regimes recorded for the two fluids are very similar, stressing that, when the dynamic effects start to play a major role in the system, the device classification between Loop Thermosyphon and Pulsating Heat Pipe is not that sharp anymore

    Preliminary Considerations from the 2nd Phase of Experiments at the SIET/SWAM Facility

    Get PDF
    Severe accident codes study the thermo-hydraulics of the suppression chamber with a limited numbers of nodes, generally solving mass and energy equations and assuming perfect mixing conditions. In a long station black out the effect of the sparger’s design might create local phenomena (e.g. stratification, hot-spots) which are hardly predicted by the current practices, resulting in mispredictions of the containment pressure evolution. In order to understand the effect of the sparger geometry, steam mass flux, water sub-cooling and air concentration the SWAM facility (Steam Water Air Mixing) at the SIET laboratory was employed performing around twenty different experiments, in conditions close to what is expected during the Fukushima Daiichi accident. The test facility (poll and pipes) is built with polycarbonate (transparent material) to ease the acquisition of the standard and high-speed cameras. Vertically distributed thermocouples and high-frequency pressure measurements are employed to obtain quantitative values for phenomena investigation and future CFD validations. It was shown that experiments with pure steam and relatively large diameter holes induce chugging that enhances mixing in the pool. Once chugging ceases, because of the reduced sub-cooling, a hot water layer is created in the upper part of the pool. The presence of air in the pipe induces large stratification from the condition of large subcooling because of the limited mixing introduced in the region below the pipe mouth

    Smart ECM-based electrospun biomaterials for skeletal muscle regeneration

    Get PDF
    The development of smart and intelligent regenerative biomaterials for skeletal muscle tissue engineering is an ongoing challenge, owing to the requirement of achieving biomimetic systems able to communicate biological signals and thus promote optimal tissue regeneration. Electrospinning is a well-known technique to produce fibers that mimic the three dimensional microstructural arrangements, down to nanoscale and the properties of the extracellular matrix fibers. Natural and synthetic polymers are used in the electrospinning process; moreover, a blend of them provides composite materials that have demonstrated the potential advantage of supporting cell function and adhesion. Recently, the decellularized extracellular matrix (dECM), which is the noncellular component of tissue that retains relevant biological cues for cells, has been evaluated as a starting biomaterial to realize composite electrospun constructs. The properties of the electrospun systems can be further improved with innovative procedures of functionalization with biomolecules. Among the various approaches, great attention is devoted to the “click” concept in constructing a bioactive system, due to the modularity, orthogonality, and simplicity features of the “click” reactions. In this paper, we first provide an overview of current approaches that can be used to obtain biofunctional composite electrospun biomaterials. Finally, we propose a design of composite electrospun biomaterials suitable for skeletal muscle tissue regeneration
    corecore