4,553 research outputs found
An investigation of atmospheric temperature profiles in the Australian region using collocated GPS radio occultation and radiosonde data
GPS radio occultation (RO) has been recognised as an alternative atmospheric upper air observation technique due to its distinct features and technological merits. The CHAllenging Minisatellite Payload (CHAMP) RO satellite and FORMOSAT-3/COSMIC (Constellation Observing System for Meteorology, Ionosphere and Climate) RO constellation together have provided about ten years of high quality global coverage RO atmospheric profiles. This technique is best used for meteorological studies in the difficult-to-access areas such as deserts and oceans. To better understand and use RO data, effective quality assessment using independent radiosonde data and its associated collocation criteria used in tempo-spatial domain are important. This study compares GPS RO retrieved temperature profiles from both CHAMP (between May 2001 and October 2008) and FORMOSAT-3/COSMIC (between July 2006 and December 2009) with radiosonde data from 38 Australian radiosonde stations. The overall results show a good agreement between the two data sets. Different collocation criteria within 3 h and 300 km between the profile pairs have been applied and the impact of these different collocation criteria on the evaluation results is found statistically insignificantly. The CHAMP and FORMOSAT-3/COSMIC temperature profiles have been evaluated at 16 different pressure levels and the differences between GPS RO and radiosonde at different levels of the atmosphere have been studied. The result shows that the mean temperature difference between radiosonde and CHAMP is 0.39 °C (with a standard deviation of 1.20 °C) and the one between radiosonde and FORMOSAT-3/COSMIC is 0.37 °C (with a standard deviation of 1.24 °C). Different collocation criteria have been applied and insignificant differences were identified amongst the results
Long-term operation of a multi-channel cosmic muon system based on scintillation counters with MRS APD light readout
A Cosmic Ray Test Facility (CRTF) is the first large-scale implementation of
a scintillation triggering system based on a new scintillation technique known
as START. In START, the scintillation light is collected and transported by WLS
optical fibers, while light detection is performed by pairs of avalanche
photodiodes with the Metal-Resistor-Semiconductor structure operated in the
Geiger mode (MRS APD). START delivers 100% efficiency of cosmic muon detection,
while its intrinsic noise level is less than 10^{-2} Hz. CRTF, consisting of
160 START channels, has been continuously operated by the ALICE TOF
collaboration for more than 25 000 hours, and has demonstrated a high level of
stability. Fewer than 10% of MRS APDs had to be replaced during this period.Comment: Proceedings of NDIP-2008. 8 pages, 8 figures, 6 reference
Integrated chemo- and biostratigraphic calibration of early animal evolution: Neoproterozoic-early Cambrian of southwest Mongolia
Five overlapping sections from the thick Neoproterozoic to early Cambrian sediments of western Mongolia were analysed to yield a remarkable carbon-isotope, strontium-isotope and small shellyfossil (SSF) record. Chemostratigraphy suggests that barren limestones of sequences 3 and 4, which lie above the two Maikhan Uul diamictites, are post-Sturtian but pre-Varangerian in age. Limestones and dolomites of sequence 5, with Boxonia grumulosa, have geochemical signatures consistent with a post-Varangerian (Ediacarian) age. A major negative δ13C anomaly (feature ‘W') in sequence 6 lies a shortdistance above an Anabarites trisulcatus Zone SSF asemblage with hexactinellid sponges, of probable late Ediacarian age. Anomaly ‘W' provides an anchor point for cross-correlation charts of carbon isotopes and small shelly fossils. Trace fossil assemblages with a distinctly Cambrian character first appear in sequence 8(Purella Zone), at the level of carbon isotopic feature ‘B', provisionally correlated with the upper part of cycle Z in Siberia. A paradox is found from sequence 10 to 12 in Mongolia: Tommotian-type SSFs continue to appear, accompanied by Nemakit-Daldynian/Tommotian-type 87Sr/86Sr ratios but by increasingly heavyδ13C values that cannot be matched in the Tommotian of eastern Siberia. The steady rate of generic diversification in Mongolia also contrasts markedly with the Tommotian ‘diversity explosion' in eastern Siberia, which occurs just above a major karstic emergence surface. One explanation is that sequences 10 to 12 in Mongolia preserve a pre-Tommotian portion of the fossil record that was missing or removed in easternSiberia. The Mongolian sections certainly deserve an important place in tracing the true course and timing of the ‘Cambrian radiation
Derived categories of Burniat surfaces and exceptional collections
We construct an exceptional collection of maximal possible length
6 on any of the Burniat surfaces with , a 4-dimensional family of
surfaces of general type with . We also calculate the DG algebra of
endomorphisms of this collection and show that the subcategory generated by
this collection is the same for all Burniat surfaces.
The semiorthogonal complement of is an "almost
phantom" category: it has trivial Hochschild homology, and K_0(\mathcal
A)=\bZ_2^6.Comment: 15 pages, 1 figure; further remarks expande
Signal Processing
Contains reports on three research projects.Joint Services Electronics Programs (U. S. Army, U. S. Navy, and U. S. Air Force) under Contract DA 28-043-AMC-02536(E
Exceptional Collections and del Pezzo Gauge Theories
Stacks of D3-branes placed at the tip of a cone over a del Pezzo surface
provide a way of geometrically engineering a small but rich class of
gauge/gravity dualities. We develop tools for understanding the resulting
quiver gauge theories using exceptional collections. We prove two important
results for a general quiver gauge theory: 1) we show the ordering of the nodes
can be determined up to cyclic permutation and 2) we derive a simple formula
for the ranks of the gauge groups (at the conformal point) in terms of the
numbers of bifundamentals. We also provide a detailed analysis of four node
quivers, examining when precisely mutations of the exceptional collection are
related to Seiberg duality.Comment: 26 pages, 1 figure; v2 footnote 2 amended; v3 ref adde
Passive mode locking of a Tm,Ho:KY(WO4)(2) laser around 2 μm
We report the first demonstration, to our knowledge, of passive mode locking in a Tm3+, Ho3+-codoped KYWO42 laser operating in the 2000-2060 nm spectral region. An InGaAsSb-based quantum well semiconductor saturable absorber mirror is used for the initiation and stabilization of the ultrashort pulse generation. Pulses as short as 3.3 ps were generated at 2057 nm with average output powers up to 315 mW at a pulse repetition frequency of 132 MHz for 1.15 W of absorbed pump power at 802 nm from a Ti:sapphire laser
Dibaryons from Exceptional Collections
We discuss aspects of the dictionary between brane configurations in del
Pezzo geometries and dibaryons in the dual superconformal quiver gauge
theories. The basis of fractional branes defining the quiver theory at the
singularity has a K-theoretic dual exceptional collection of bundles which can
be used to read off the spectrum of dibaryons in the weakly curved dual
geometry. Our prescription identifies the R-charge R and all baryonic U(1)
charges Q_I with divisors in the del Pezzo surface without any Weyl group
ambiguity. As one application of the correspondence, we identify the cubic
anomaly tr R Q_I Q_J as an intersection product for dibaryon charges in large-N
superconformal gauge theories. Examples can be given for all del Pezzo surfaces
using three- and four-block exceptional collections. Markov-type equations
enforce consistency among anomaly equations for three-block collections.Comment: 47 pages, 11 figures, corrected ref
IoT based system for real-time monitoring the hydrogen-ion activity in water bodies
The paper presents design and principle of operation of a mobile combined pH meter. Sensor’s network underlying the IoT system for monitoring water bodies hydrogen ions activity in real time was demonstrated. The measuring device was tested on liquids with different pH levels. The obtained measurement results were compared using a stationary pH meter OHAUS Starter 3100
- …