215,768 research outputs found

    Pulsar Velocity with Three-Neutrino Oscillations in Non-adiabatic Processes

    Full text link
    We have studied the position dependence of neutrino energy on the Kusenko-Segr\`{e} mechanism as an explanation of the proper motion of pulsars. The mechanism is also examined in three-generation mixing of neutrinos and in a non-adiabatic case. The position dependence of neutrino energy requires the higher value of magnetic field such as B3×1015B\sim 3\times 10^{15} Gauss in order to explain the observed proper motion of pulsars. It is shown that possible non-adiabatic processes decrease the neutrino momentum asymmetry, whereas an excess of electron neutrino flux over other flavor neutrino fluxes increases the neutrino momentum asymmetry. It is also shown that a general treatment with all three neutrinos does not modify the result of the two generation treatment if the standard neutrino mass hierarchy is assumed.Comment: 8 pages, REVTEX, no figure

    Implicit Filter Sparsification In Convolutional Neural Networks

    No full text
    We show implicit filter level sparsity manifests in convolutional neural networks (CNNs) which employ Batch Normalization and ReLU activation, and are trained with adaptive gradient descent techniques and L2 regularization or weight decay. Through an extensive empirical study (Mehta et al., 2019) we hypothesize the mechanism behind the sparsification process, and find surprising links to certain filter sparsification heuristics proposed in literature. Emergence of, and the subsequent pruning of selective features is observed to be one of the contributing mechanisms, leading to feature sparsity at par or better than certain explicit sparsification / pruning approaches. In this workshop article we summarize our findings, and point out corollaries of selective-featurepenalization which could also be employed as heuristics for filter prunin

    Arterial pulse wave pressure transducer

    Get PDF
    An arterial pulse wave pressure transducer is introduced. The transducer is comprised of a fluid filled cavity having a flexible membrane disposed over the cavity and adapted to be placed on the skin over an artery. An arterial pulse wave creates pressure pulses in the fluid which are transduced, by a pressure sensitive transistor in direct contact with the fluid, into an electric signal. The electrical signal is representative of the pulse waves and can be recorded so as to monitor changes in the elasticity of the arterial walls

    An economical arterial-pulse-wave transducer

    Get PDF
    Transducer records arterial pulses externally. Device uses thin plastic membrane which is fluid coupled to pressure sensitive transistor. Transistor is connected to amplifier which, in turn, is connected to recorder. End section is threaded to accept suitable holder and contains pressure relief vent allowing transistor to sense only pressure levels greater than atmospheric
    corecore