3,246 research outputs found
Detecting Spin-Polarized Currents in Ballistic Nanostructures
We demonstrate a mesoscopic spin polarizer/analyzer system that allows the
spin polarization of current from a quantum point contact in an in-plane
magnetic field to be measured. A transverse focusing geometry is used to couple
current from an emitter point contact into a collector point contact. At large
in-plane fields, with the point contacts biased to transmit only a single spin
(g < e^2/h), the voltage across the collector depends on the spin polarization
of the current incident on it. Spin polarizations of greater than 80% are found
for both emitter and collector at 300mK and 7T in-plane field.Comment: related papers at http://marcuslab.harvard.ed
Mechanical suppression of osteolytic bone metastases in advanced breast cancer patients: A randomised controlled study protocol evaluating safety, feasibility and preliminary efficacy of exercise as a targeted medicine
Background: Skeletal metastases present a major challenge for clinicians, representing an advanced and typically incurable stage of cancer. Bone is also the most common location for metastatic breast carcinoma, with skeletal lesions identified in over 80% of patients with advanced breast cancer. Preclinical models have demonstrated the ability of mechanical stimulation to suppress tumour formation and promote skeletal preservation at bone sites with osteolytic lesions, generating modulatory interference of tumour-driven bone remodelling. Preclinical studies have also demonstrated anti-cancer effects through exercise by minimising tumour hypoxia, normalising tumour vasculature and increasing tumoural blood perfusion. This study proposes to explore the promising role of targeted exercise to suppress tumour growth while concomitantly delivering broader health benefits in patients with advanced breast cancer with osteolytic bone metastases.
Methods: This single-blinded, two-armed, randomised and controlled pilot study aims to establish the safety, feasibility and efficacy of an individually tailored, modular multi-modal exercise programme incorporating spinal isometric training (targeted muscle contraction) in 40 women with advanced breast cancer and stable osteolytic spinal metastases. Participants will be randomly assigned to exercise or usual medical care. The intervention arm will receive a 3-month clinically supervised exercise programme, which if proven to be safe and efficacious will be offered to the control-arm patients following study completion. Primary endpoints (programme feasibility, safety, tolerance and adherence) and secondary endpoints (tumour morphology, serum tumour biomarkers, bone metabolism, inflammation, anthropometry, body composition, bone pain, physical function and patient-reported outcomes) will be measured at baseline and following the intervention.
Discussion: Exercise medicine may positively alter tumour biology through numerous mechanical and nonmechanical mechanisms. This randomised controlled pilot trial will explore the preliminary effects of targeted exercise on tumour morphology and circulating metastatic tumour biomarkers using an osteolytic skeletal metastases model in patients with breast cancer. The study is principally aimed at establishing feasibility and safety. If proven to be safe and feasible, results from this study could have important implications for the delivery of this exercise programme to patients with advanced cancer and sclerotic skeletal metastases or with skeletal lesions present in haematological cancers (such as osteolytic lesions in multiple myeloma), for which future research is recommended.
Trial registration: anzctr.org.au, ACTRN-12616001368426. Registered on 4 October 2016
How branching can change the conductance of ballistic semiconductor devices
We demonstrate that branching of the electron flow in semiconductor
nanostructures can strongly affect macroscopic transport quantities and can
significantly change their dependence on external parameters compared to the
ideal ballistic case even when the system size is much smaller than the mean
free path. In a corner-shaped ballistic device based on a GaAs/AlGaAs
two-dimensional electron gas we observe a splitting of the commensurability
peaks in the magnetoresistance curve. We show that a model which includes a
random disorder potential of the two-dimensional electron gas can account for
the random splitting of the peaks that result from the collimation of the
electron beam. The shape of the splitting depends on the particular realization
of the disorder potential. At the same time magnetic focusing peaks are largely
unaffected by the disorder potential.Comment: accepted for publication in Phys. Rev.
Paediatric Over-the-Counter (OTC) Oral Liquids Can Soften and Erode Enamel
published_or_final_versio
Spin separation in cyclotron motion
Charged carriers with different spin states are spatially separated in a
two-dimensional hole gas. Due to strong spin-orbit interaction holes at the
Fermi energy have different momenta for two possible spin states travelling in
the same direction and, correspondingly, different cyclotron orbits in a weak
magnetic field. Two point contacts, acting as a monochromatic source of
ballistic holes and a narrow detector in the magnetic focusing geometry are
demonstrated to work as a tunable spin filter.Comment: 4 pages, 2 figure
The Open Access Advantage Revisited
This paper is a revision of one that appeared in 2008, incorporating the many developments and changes that have happened since then.published_or_final_versio
Accurate Liability Estimation Improves Power in Ascertained Case Control Studies
Linear mixed models (LMMs) have emerged as the method of choice for
confounded genome-wide association studies. However, the performance of LMMs in
non-randomly ascertained case-control studies deteriorates with increasing
sample size. We propose a framework called LEAP (Liability Estimator As a
Phenotype, https://github.com/omerwe/LEAP) that tests for association with
estimated latent values corresponding to severity of phenotype, and demonstrate
that this can lead to a substantial power increase
Electron focusing, mode spectroscopy and mass enhancement in small GaAs/AlGaAs rings
A new electron focusing effect has been discovered in small single and
coupled GaAs/AlGaAs rings. The focusing in the single ring is attributed solely
to internal orbits. The focusing effect allows the ring to be used as a small
mass spectrometer. The focusing causes peaks in the magnetoresistance at low
fields, and the peak positions were used to study the dispersion relation of
the one-dimensional magnetoelectric subbands. The electron effective mass
increases with the applied magnetic field by a factor of , at a magnetic
field of . This is the first time this increase has been measured
directly. General agreement obtains between the experiment and the subband
calculations for straight channels.Comment: 13 pages figures are available by reques
Theory of Current-Induced Magnetization Precession
We solve appropriate drift-diffusion and Landau-Lifshitz-Gilbert equations to
demonstrate that unpolarized current flow from a non-magnet into a ferromagnet
can produce a precession-type instability of the magnetization. The fundamental
origin of the instability is the difference in conductivity between majority
spins and minority spins in the ferromagnet. This leads to spin accumulation
and spin currents that carry angular momentum across the interface. The
component of this angular momentum perpendicular to the magnetization drives
precessional motion that is opposed by Gilbert damping. Neglecting magnetic
anisotropy and magnetostatics, our approximate analytic and exact numerical
solutions using realistic values for the material parameters show (for both
semi-infinite and thin film geometries) that a linear instability occurs when
both the current density and the excitation wave vector parallel to the
interface are neither too small nor too large. For many aspects of the problem,
the variation of the magnetization in the direction of the current flows makes
an important contribution.Comment: Submitted to Physical Review
- …
