159 research outputs found

    Presence of Campylobacter and Salmonella spp. in Poultry and Environmental Samples from Farm to Retail in Hungary

    Get PDF
    The aim of this study was to investigate the occurrence of Salmonella enterica and its most important serovars Salmonella Infantis, Salmonella Enteritidis, Salmonella Typhimurium, and Campylobacter spp. in the broiler meat production chain. Altogether 110 pooled samples were analysed; environment, cloaca, body surface at the farm, then carcass, offal, and packed meat from the slaughterhouse. The combination of redox potential measurement and realtime PCR was used for the detection of the microbes. At the farm, the first Salmonella positive result came from the water system, then it appeared in most of the samples. In contrast to the absence of Salmonella on the birdsā€™ body surface before transportation, by the end of the processing it had reached 100%, with the only identifiable serovar being S. Infantis (65%). All packed meat samples showed positivity, from which 70% was S. Infantis. Campylobacter appeared at the farm on the 3rd week and remained significant during the breeding. After the slaughtering process, the contamination was 100% in the carcass, offal, and packaged meat samples. Our results demonstrated the success of the Salmonella control program, by the low prevalence of S. Typhimurium and Enteritidis

    Ablation lesions in Koch's triangle assessed by three-dimensional myocardial contrast echocardiography

    Get PDF
    BACKGROUND: Myocardial contrast echocardiography (MCE) allows visualization of radiofrequency (RF) ablation lesions in the left ventricle in an animal model. Aim: To test whether MCE allows visualization of RF and cryo ablation lesions in the human right atrium using three-dimensional echocardiography. METHODS: 18 patients underwent catheter ablation of a supraventricular tachycardia and were included in this prospective single-blind study. Twelve patients were ablated inside Koch's triangle and 6, who served as controls, outside this area. Three-dimensional echocardiography of Koch's triangle was performed before and after the ablation procedure in all patients, using respiration and ECG gated pullback of a 9 MHz ICE transducer, with and without continuous intravenous echocontrast infusion (SonoVue, Bracco). Two independent observers analyzed the data off-line. RESULTS: MCE identified ablation lesions as a low contrast area within the normal atrial myocardial tissue. Craters on the endocardial surface were seen in 10 (83%) patients after ablation. Lesions were identified in 11 out of 12 patients (92%). None of the control patients were recognized as having been ablated. The confidence score of the independent echo reviewer tended to be higher when the number of applications increased. CONCLUSIONS: 1. MCE allows direct visualization of ablation lesions in the human atrial myocardium. 2. Both RF and cryo energy lesions can be identified using MCE

    High-volume lesions using a new second-generation open irrigation radiofrequency catheter are associated with the development of inhomogeneous lesions

    Get PDF
    BACKGROUND: After catheter ablation there is often a discrepancy between acute and chronic success rates. We aimed to evaluate major determinants for lesion quality and understand different manifestations of lesion structures. METHODS: In a canine thigh muscle model radiofrequency (RF) current was delivered for 60 seconds at 30 W (n = 39) or 50 W (n = 18) with 15-g contact force. A second-generation 12-hole gold open irrigation catheter (SGIT) and a first-generation six-hole platinum-iridium catheter (FGIT; Biotronik, Berlin, Germany) were used. Electrode and tissue temperatures (at the surface and 3.5-mm and 7-mm depth) were recorded and lesion dimensions were measured. Lesions with steam pops were excluded. Histological examination was performed to evaluate homogeneity of the lesions. Inhomogeneity was defined as a visual multiband lesion pattern indicating different histological characteristics. RESULTS: In total 57 lesions were created. Seventeen lesions were excluded (steam pops) and 40 lesions were analyzed. A total number of 11 homogeneous and 29 inhomogeneous lesions were identified. Using the SGIT catheter 16.7% of the lesions was homogeneous and 83.3% inhomogeneous; for FGIT it was 43.8% and 56.2% (P = 0.065), respectively. Homogeneous lesions had lower volumes as compared to inhomogeneous lesions (514.0 +/- 198.8 vs 914.8 +/- 399.1 mm, P = 0.003). Multiple logistic regression analysis indicated that the SGIT catheter is a significant predictor for inhomogeneous lesions (odds ratio 6.5, 95% confidence interval 1.1-38.8; P = 0.040) independent from power setting and flow rate. CONCLUSIONS: The development of inhomogeneous lesions after acute RF ablation is associated with higher lesion volumes and the use of the second-generation irrigation gold-tip catheter

    Visualization of elusive structures using intracardiac echocardiography: Insights from electrophysiology

    Get PDF
    Electrophysiological mapping and ablation techniques are increasingly used to diagnose and treat many types of supraventricular and ventricular tachycardias. These procedures require an intimate knowledge of intracardiac anatomy and their use has led to a renewed interest in visualization of specific structures. This has required collaborative efforts from imaging as well as electrophysiology experts. Classical imaging techniques may be unable to visualize structures involved in arrhythmia mechanisms and therapy. Novel methods, such as intracardiac echocardiography and three-dimensional echocardiography, have been refined and these technological improvements have opened new perspectives for more effective and accurate imaging during electrophysiology procedures. Concurrently, visualization of these structures noticeably improved our ability to identify intracardiac structures. The aim of this review is to provide electrophysiologists with an overview of recent insights into the structure of the heart obtained with intracardiac echocardiography and to indicate to the echo-specialist which structures are potentially important for the electrophysiologist

    Tracking the Penetration of Plasma Reactive Species in Tissue Models

    Get PDF
    Electrically generated cold atmospheric plasma is being intensively researched for novel applications in biology and medicine. Significant attention is being given to reactive oxygen and nitrogen species (RONS), initially generated upon plasmaā€“air interactions, and subsequently delivered to biological systems. Effects of plasma exposure are observed to millimeter depths within tissue. However, the exact nature of the initial plasmaā€“tissue interactions remains unknown, including RONS speciation and delivery depth, or how plasma-derived RONS intervene in biological processes. Herein, we focus on current research using tissue and cell models to learn more about the plasma delivery of RONS into biological environments. We argue that this research is vital in underpinning the knowledge required to realize the full potential of plasma in biology and medicine

    Clinical experience with a novel subcutaneous implantable defibrillator system in a single center

    Get PDF
    Background: Implantable cardioverter-defibrillators (ICDs) reduce mortality in both primary and secondary prevention, but are associated with substantial short- and long-term morbidity. A totally subcutaneous ICD (S-ICD) system has been developed. We report the initial clinical experience of the first 31 patients implanted at our hospital. Methods: All patients had an ICD indication according to the ACC/AHA/ESC guidelines. The first 11 patients were part of the reported CE trial. The implantation was performed without fluoroscopy. The device was implanted subcutaneously in the anterior axillary line, with a parasternal lead tunneled from the xiphoid to the manubrial-sternal junction. Ventricular fibrillation (VF) was induced to assess detection accuracy and defibrillation efficacy using 65 J shocks. Results: Post-implant, 52 sustained episodes of VF were induced. Sensitivity was 100% and induced conversion efficacy was 100% (with standard polarity in 29 patients). Mean time to therapy was 13.9 Ā± 2.5 s (range 11-21.6 s). Late procedure-related complications were observed in 2 of the first 11 implantations (lead migration). During follow-up, spontaneous ventricular arrhythmias occurred in four patients, with accurate detection of all episodes. Inappropriate therapy was observed in five patients. Recurrences were prevented with reprogramming. Conclusions: The S-ICD system can be implanted without the use of fluoroscopy by using anatomical landmarks only. Episodes of VF were accurately detected using subcutaneous signals, and all induced and clinical episodes were successfully converted. The S-ICD system is a viable alternative to conventional ICD systems for selected patients

    Contact feedback improves 1-year outcomes of remote magnetic navigation-guided ischemic ventricular tachycardia ablation

    Get PDF
    Introduction: Remote magnetic navigation (RMN)-guided catheter ablation (CA) is a feasible treatment option for patients presenting with ischemic ventricular tachycardia (VT). Catheter-tissue contact feedback, enhances lesion formation and may consequently improve CA outcomes. Until recently, contact feedback was unavailable for RMN-guided CA. The novel e-Contact Module (ECM) was developed to continuously monitor and ensure catheter-tissue contact during RMN-guided CA. Objective: The present study aims to evaluate the effect of ECM implementation on acute and long-term outcomes in RMN-guided ischemic VT ablation. Method: This retrospective, two-center study included consecutive ischemic VT patients undergoing RMN-guided CA from 2010 to 2017. Baseline clinical data, procedural data, including radiation times, and acute success rates were compared between CA procedures performed with ECM (ECM+) and without ECM (ECMāˆ’). One-year VT-free survival was analyzed using Cox-proportional hazards models, adjusting for potential confounders: age, left ventricular function, VT inducibility at baseli
    • ā€¦
    corecore