45 research outputs found
Radiation dose reduction in pediatric great vessel stent computed tomography using iterative reconstruction: A phantom study
Background To study dose reduction using iterative reconstruction (IR) for pediatric great vessel stent computed tomography (CT). Methods Five different great vessel stents were separately placed in a gel-containing plastic holder within an anthropomorphic chest phantom. The stent lumen was filled with diluted contrast gel. CT acquisitions were performed at routine dose, 52% and 81% reduced dose and reconstructed with filtered back projection (FBP) and IR. Objective image quality in terms of noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) as well as subjective image quality were evaluated. Results Noise, SNR and CNR were improved with IR at routine and 52% reduced dose, compared to FBP at routine dose. The lowest dose level resulted in decreased objective image quality with both FBP and IR. Subjective image quality was excellent at all dose levels. Conclusion IR resulted in improved objective image quality at routine dose and 52% reduced dose, while objective image quality deteriorated at 81% reduced dose. Subjective image quality was not affected by dose reduction
Baseline MDCT findings after prosthetic heart valve implantation provide important complementary information to echocardiography for follow-up purposes
Objectives: Recent studies have proposed additional multidetector-row CT (MDCT) for prosthetic heart valve (PHV) dysfunction. References to discriminate physiological from pathological conditions early after implantation are lacking. We present baseline MDCT findings of PHVs 6 weeks post implantation. Methods: Patients were prospectively enrolled and TTE was performed according to clinical guidelines. 256-MDCT images were systematically assessed for leaflet excursions, image quality, valve-related artefacts, and pathological and additional findings. Results: Forty-six patients were included comprising 33 mechanical and 16 biological PHVs. Overall, MDCT image quality was good and relevant regions remained reliably assessable despite mild-moderate PHV-artefacts. MDCT detected three unexpected valve-related pathology cases: (1) prominent subprosthetic tissue, (2) pseudoaneurysm and (3) extensive pseudoaneurysms and valve dehiscence. The latter patient required valve surgery to be redone. TTE only showed trace periprosthetic regurgitation, and no abnormalities in the other cases. Additional findings were: tilted aortic PHV position (n = 3), pericardial haematoma (n = 3) and pericardial effusion (n = 3). Periaortic induration was present in 33/40 (83 %) aortic valve patients. Conclusions: MDCT allowed evaluation of relevant PHV regions in all valves, revealed baseline postsurgical findings and, despite normal TTE findings, detected three cases of unexpected, clinically relevant pathology. Key Points: • Postoperative MDCT presents baseline morphology relevant for prosthetic valve follow-up. • 83 % of patients show periaortic induration 6 weeks after aortic valve replacement. • MDCT detected three cases of clinically relevant pathology not found with TTE. • Valve dehiscence detection by MDCT required redo valve surgery in one patient. • MDCT is a suitable and complementary imaging tool for follow-up purposes
Imaging of pediatric great vessel stents: Computed tomography or magnetic resonance imaging?
__Background:__ Complications might occur after great vessel stent implantation in children. Therefore follow- up using imaging is warranted.
__Purpose:__ To determine the optimal imaging modality for the assessment of stents used to treat great vessel obstructions in children.
__Material and methods:__ Five different large vessel stents were evaluated in an in-vitro setting. All stents were expanded to the maximal vendor recommended diameter (20mm; n = 4 or 10mm; n = 1), placed in an anthropomorphic chest phantom and imaged with a 256-slice CT-scanner. MRI images were acquired at 1.5T using a multi-slice T2-weighted turbo spin echo, an RFspoiled three-dimensional T1-weighted Fast Field Echo and a balanced turbo field echo 3D seq
Internet gaming disorder and risky behaviours among Czech adolescents: a nationally representative study
Background and aims: The aim of the present study was to estimate the complex association between Internet Gaming Disorder (IGD), substance use, and other risky behaviours in Czech adolescents whilst providing prevalence estimates of IGD and psychometric information regarding the Czech Internet Gaming Disorder Scale–Short-Form (IGDS9-SF). Methods:
A representative sample of 3,950 Czech adolescents was recruited through stratified random sampling in the school setting. Results:
Disordered gamers showed frequent use of specific substances such as pharmaceuticals, methylenedioxymethamphetamine, and lysergic acid diethylamide. In contrast, non-gamers had higher prevalence of alcohol, cigarettes, sedatives and tranquillisers, and marijuana use. A logistic regression, utilising IGDS9-SF raw scores and average daily gaming time, revealed a U-shaped relationship between gaming and both alcohol and cigarette use. Additionally, conduct problems such as bullying, and risky in-game behaviours were more prevalent among disordered gamers, with the exception of forging parents' signatures. The overall prevalence of IGD was 3.62% (95% CI = [3.1%, 4.3%]), with higher rates in males (5.89%; 95% CI = [4.9%, 7.0%]) than in females (1.45%; 95% CI = [1.0%, 2.1%]). Discussion and conclusions: The Czech IGDS9-SF used in the present study showed adequate psychometric properties. The association between gaming and substance use behaviours may be specific and multifaceted depending on the severity of the gaming-related problems. Furthermore, disordered gamers may become more vulnerable due to a higher incidence of conduct problems, bullying (victimisation), and in-game risky behaviours such as engagement with microtransactions mechanics (e.g., loot box) within video games
Halved contrast medium dose coronary dual-layer CT-angiography - phantom study of tube current and patient characteristics
Virtual mono-energetic images (VMI) using dual-layer computed tomography (DLCT) enable substantial contrast medium (CM) reductions. However, the combined impact of patient size, tube voltage, and heart rate (HR) on VMI of coronary CT angiography (CCTA) remains unknown. This phantom study aimed to assess VMI levels achieving comparable contrast-to-noise ratio (CNR) in CCTA at 50% CM dose across varying tube voltages, patient sizes, and HR, compared to the reference protocol (100% CM dose, conventional at 120 kVp). A 5 mm artificial coronary artery with 100% (400 HU) and 50% (200 HU) iodine CM-dose was positioned centrally in an anthropomorphic thorax phantom. Horizontal coronary movement was matched to HR (at 0, < 60, 60-75, > 75 bpm), with varying patient sizes simulated using phantom extension rings. Raw data was acquired using a clinical CCTA protocol at 120 and 140 kVp (five repetitions). VMI images (40-70 keV, 5 keV steps) were then reconstructed; non-overlapping 95% CNR confidence intervals indicated significant differences from the reference. Higher CM-dose, reduced VMI, slower HR, higher tube voltage, and smaller patient sizes demonstrated a trend of higher CNR. Regardless of HR, patient size, and tube voltage, no significant CNR differences were found compared to the reference, with 100% CM dose at 60 keV, or 50% CM dose at 40 keV. DLCT reconstructions at 40 keV from 120 to 140 kVp acquisitions facilitate 50% CM dose reduction for various patient sizes and HR with equivalent CNR to conventional CCTA at 100% CM dose, although clinical validation is needed.</p
Surgically implanted aortic valve bioprostheses deform after implantation: insights from computed tomography
Objective: Little is known about the prevalence and degree of deformation of surgically implanted aortic biological valve prostheses (bio-sAVRs). We assessed bio-sAVR deformation using multidetector-row computed tomography (MDCT). Methods: Three imaging databases were searched for patients with MDCT performed after bio-sAVR implantation. Minimal and maximal valve ring diameters were obtained in systole and/or diastole, depending on the acquired cardiac phase(s). The eccentricity index (EI) was calculated as a measure of deformation as (1 − (minimal diameter/maximal diameter)) × 100%. EI of 10% non-circular. Indications for MDCT and implanted valve type were retrieved. Results: One hundred fifty-two scans of bio-sAVRs were included. One hundred seventeen measurements were performed in systole and 35 in diastole. None or trivial deformation (EI 5%) in 56% of studied cases and were considered non-circular (eccentricity index > 10%) in 17% of studied valves. • The higher deformity rate found in bio-sAVRs with (suspected) valve pathology could suggest that geometric deformity may play a role in leaflet malformation and thrombus formation similar to that of transcatheter heart valves
Standards for conducting and reporting consensus and recommendation documents: European Society of Cardiovascular Radiology policy from the Guidelines Committee.
Cardiovascular imaging is exponentially increasing in the diagnosis, risk stratification, and therapeutic management of patients with cardiovascular disease. The European Society of Cardiovascular Radiology (ESCR) is a non-profit scientific medical society dedicated to promoting and coordinating activities in cardiovascular imaging. The purpose of this paper, written by ESCR committees and Executive board members and approved by the ESCR Executive Board and Guidelines committee, is to codify a standardized approach to creating ESCR scientific documents. Indeed, consensus development methods must be adopted to ensure transparent decision-making that optimizes national and global health and reaches a certain scientific credibility. ESCR consensus documents developed based on a rigorous methodology will improve their scientific impact on the management of patients with cardiac involvement. CRITICAL RELEVANCE STATEMENT: This document aims to codify the methodology for producing consensus documents of the ESCR. These ESCR indications will broaden the scientific quality and credibility of further publications and, consequently, the impact on the diagnostic management of patients with cardiac involvement. KEY POINTS: Cardiovascular imaging is exponentially increasing for diagnosis, risk stratification, and therapeutic management. The ESCR is committed to promoting cardiovascular imaging. A rigorous methodology for ESCR consensus documents will improve their scientific impact
Halved contrast medium dose coronary dual-layer CT-angiography – phantom study of tube current and patient characteristics
Virtual mono-energetic images (VMI) using dual-layer computed tomography (DLCT) enable substantial contrast medium (CM) reductions. However, the combined impact of patient size, tube voltage, and heart rate (HR) on VMI of coronary CT angiography (CCTA) remains unknown. This phantom study aimed to assess VMI levels achieving comparable contrast-to-noise ratio (CNR) in CCTA at 50% CM dose across varying tube voltages, patient sizes, and HR, compared to the reference protocol (100% CM dose, conventional at 120 kVp). A 5 mm artificial coronary artery with 100% (400 HU) and 50% (200 HU) iodine CM-dose was positioned centrally in an anthropomorphic thorax phantom. Horizontal coronary movement was matched to HR (at 0, 75 bpm), with varying patient sizes simulated using phantom extension rings. Raw data was acquired using a clinical CCTA protocol at 120 and 140 kVp (five repetitions). VMI images (40–70 keV, 5 keV steps) were then reconstructed; non-overlapping 95% CNR confidence intervals indicated significant differences from the reference. Higher CM-dose, reduced VMI, slower HR, higher tube voltage, and smaller patient sizes demonstrated a trend of higher CNR. Regardless of HR, patient size, and tube voltage, no significant CNR differences were found compared to the reference, with 100% CM dose at 60 keV, or 50% CM dose at 40 keV. DLCT reconstructions at 40 keV from 120 to 140 kVp acquisitions facilitate 50% CM dose reduction for various patient sizes and HR with equivalent CNR to conventional CCTA at 100% CM dose, although clinical validation is needed
Standards for conducting and reporting consensus and recommendation documents: European Society of Cardiovascular Radiology policy from the Guidelines Committee
Abstract: Cardiovascular imaging is exponentially increasing in the diagnosis, risk stratification, and therapeutic management of patients with cardiovascular disease. The European Society of Cardiovascular Radiology (ESCR) is a non-profit scientific medical society dedicated to promoting and coordinating activities in cardiovascular imaging. The purpose of this paper, written by ESCR committees and Executive board members and approved by the ESCR Executive Board and Guidelines committee, is to codify a standardized approach to creating ESCR scientific documents. Indeed, consensus development methods must be adopted to ensure transparent decision-making that optimizes national and global health and reaches a certain scientific credibility. ESCR consensus documents developed based on a rigorous methodology will improve their scientific impact on the management of patients with cardiac involvement. Critical relevance statement: This document aims to codify the methodology for producing consensus documents of the ESCR. These ESCR indications will broaden the scientific quality and credibility of further publications and, consequently, the impact on the diagnostic management of patients with cardiac involvement. Key Points: Cardiovascular imaging is exponentially increasing for diagnosis, risk stratification, and therapeutic management. The ESCR is committed to promoting cardiovascular imaging. A rigorous methodology for ESCR consensus documents will improve their scientific impact