744 research outputs found

    Correlations in nano-scale step fluctuations: comparison of simulation and experiments

    Full text link
    We analyze correlations in step-edge fluctuations using the Bortz-Kalos-Lebowitz kinetic Monte Carlo algorithm, with a 2-parameter expression for energy barriers, and compare with our VT-STM line-scan experiments on spiral steps on Pb(111). The scaling of the correlation times gives a dynamic exponent confirming the expected step-edge-diffusion rate-limiting kinetics both in the MC and in the experiments. We both calculate and measure the temperature dependence of (mass) transport properties via the characteristic hopping times and deduce therefrom the notoriously-elusive effective energy barrier for the edge fluctuations. With a careful analysis we point out the necessity of a more complex model to mimic the kinetics of a Pb(111) surface for certain parameter ranges.Comment: 10 pages, 9 figures, submitted to Physical Review

    Imaging Cerenkov emission as a quality assurance tool in electron radiotherapy

    Get PDF
    A new potential quality assurance (QA) method is explored (including assessment of depth dose, dose linearity, dose rate linearity and beam profile) for clinical electron beams based on imaging Cerenkov light. The potential of using a standard commercial camera to image Cerenkov light generated from electrons in water for fast QA measurement of a clinical electron beam was explored and compared to ionization chamber measurements. The new method was found to be linear with dose and independent of dose rate (to within 3%). The uncorrected practical range measured in Cerenkov images was found to overestimate the actual value by 3 mm in the worst case. The field size measurements underestimated the dose at the edges by 5% without applying any correction factor. Still, the measured field size could be used to monitor relative changes in the beam profile. Finally, the beam-direction profile measurements were independent of the field size within 2%. A simulation was also performed of the deposited energy and of Cerenkov production in water using GEANT4. Monte Carlo simulation was used to predict the measured light distribution around the water phantom, to reproduce Cerenkov images and to find the relation between deposited energy and Cerenkov production. The camera was modelled as a pinhole camera in GEANT4, to attempt to reproduce Cerenkov images. Simulations of the deposited energy and the Cerenkov light production agreed with each other for a pencil beam of electrons, while for a realistic field size, Cerenkov production in the build-up region overestimated the dose by +8%

    Performance of a novel wafer scale CMOS active pixel sensor for bio-medical imaging

    Get PDF
    Recently CMOS Active Pixels Sensors (APSs) have become a valuable alternative to amorphous Silicon and Selenium Flat Panel Imagers (FPIs) in bio-medical imaging applications. CMOS APSs can now be scaled up to the standard 20 cm diameter wafer size by means of a reticle stitching block process. However despite wafer scale CMOS APS being monolithic, sources of non-uniformity of response and regional variations can persist representing a significant challenge for wafer scale sensor response. Non-uniformity of stitched sensors can arise from a number of factors related to the manufacturing process, including variation of amplification, variation between readout components, wafer defects and process variations across the wafer due to manufacturing processes. This paper reports on an investigation into the spatial non-uniformity and regional variations of a wafer scale stitched CMOS APS. For the first time a per-pixel analysis of the electro-optical performance of a wafer CMOS APS is presented, to address inhomogeneity issues arising from the stitching techniques used to manufacture wafer scale sensors. A complete model of the signal generation in the pixel array has been provided and proved capable of accounting for noise and gain variations across the pixel array. This novel analysis leads to readout noise and conversion gain being evaluated at pixel level, stitching block level and in regions of interest, resulting in a coefficient of variation ≤ 1.9%. The uniformity of the image quality performance has been further investigated in a typical X-ray application, i.e. mammography, showing a uniformity in terms of CNR among the highest when compared with mammography detectors commonly used in clinical practise. Finally, in order to compare the detection capability of this novel APS with the currently used technology (i.e. FPIs), theoretical evaluation of the Detection Quantum Efficiency (DQE) at zero-frequency has been performed, resulting in a higher DQE for this detector compared to FPIs. Optical characterization, X-ray contrast measurements and theoretical DQE evaluation suggest that a trade off can be found between the need of a large imaging area and the requirement of a uniform imaging performance, making the DynAMITe large area CMOS APS suitable for a range of bio-medical applications

    Conformity of spin fluctuations in alkali-metal iron selenide superconductors inferred from the observation of a magnetic resonant mode in K(x)Fe(2-y)Se(2)

    Full text link
    Spin excitations stemming from the metallic phase of the ferrochalcogenide superconductor K(0.77)Fe(1.85)Se(2) (T_c=32 K) were mapped out in the ab plane by means of the time-of-flight neutron spectroscopy. We observed a magnetic resonant mode at Q_res=(1/2 1/4), whose energy and in-plane shape are almost identical to those in the related compound Rb(0.8)Fe(1.6)Se(2). This lets us infer that there is a unique underlying electronic structure of the bulk superconducting phase K(x)Fe(2)Se(2), which is universal for all alkali-metal iron selenide superconductors and stands in contrast to the doping-tunable phase diagrams of the related iron pnictides. Furthermore, the spectral weight of the resonance on the absolute scale, normalized to the volume fraction of the superconducting phase, is several times larger than in optimally doped BaFe(2-x)Co(x)As(2). We also found no evidence for any additional low-energy branches of spin excitations away from Q_res. Our results provide new input for theoretical models of the spin dynamics in iron based superconductors

    Fluctuations, line tensions, and correlation times of nanoscale islands on surfaces

    Full text link
    We analyze in detail the fluctuations and correlations of the (spatial) Fourier modes of nano-scale single-layer islands on (111) fcc crystal surfaces. We analytically show that the Fourier modes of the fluctuations couple due to the anisotropy of the crystal, changing the power spectrum of the fluctuations, and that the actual eigenmodes of the fluctuations are the appropriate linear combinations of the Fourier modes. Using kinetic Monte Carlo simulations with bond-counting parameters that best match realistic energy barriers for hopping rates, we deduce absolute line tensions as a function of azimuthal orientation from the analyses of the fluctuation of each individual mode. The autocorrelation functions of these modes give the scaling of the correlation times with wavelength, providing us with the rate-limiting kinetics driving the fluctuations, here step-edge diffusion. The results for the energetic parameters are in reasonable agreement with available experimental data for Pb(111) surfaces, and we compare the correlation times of island-edge fluctuations to relaxation times of quenched Pb crystallites.Comment: 11 pages, 8 figures; to appear in PRB 70, xxx (15 Dec 2004), changes in MC and its implication

    Results from phase 1 of the HAYSTAC microwave cavity axion experiment

    Full text link
    We report on the results from a search for dark matter axions with the HAYSTAC experiment using a microwave cavity detector at frequencies between 5.6-5.8Ghz\, \rm Ghz. We exclude axion models with two photon coupling gaγγ2×1014GeV1g_{a\gamma\gamma}\,\gtrsim\,2\times10^{-14}\,\rm GeV^{-1}, a factor of 2.7 above the benchmark KSVZ model over the mass range 23.15<\,<\,mam_a \,<\,24.0μeV\,\mu\rm eV. This doubles the range reported in our previous paper. We achieve a near-quantum-limited sensitivity by operating at a temperature T<hν/2kBT<h\nu/2k_B and incorporating a Josephson parametric amplifier (JPA), with improvements in the cooling of the cavity further reducing the experiment's system noise temperature to only twice the Standard Quantum Limit at its operational frequency, an order of magnitude better than any other dark matter microwave cavity experiment to date. This result concludes the first phase of the HAYSTAC program utilizing a conventional copper cavity and a single JPA

    Results from the Super Cryogenic Dark Matter Search (SuperCDMS) experiment at Soudan

    Get PDF
    We report the result of a blinded search for Weakly Interacting Massive Particles (WIMPs) using the majority of the SuperCDMS Soudan dataset. With an exposure of 1690 kg days, a single candidate event is observed, consistent with expected backgrounds. This analysis (combined with previous Ge results) sets an upper limit on the spin-independent WIMP--nucleon cross section of 1.4×10441.4 \times 10^{-44} (1.0×10441.0 \times 10^{-44}) cm2^2 at 46 GeV/c2c^2. These results set the strongest limits for WIMP--germanium-nucleus interactions for masses >>12 GeV/c2c^2

    CDMSlite: A Search for Low-Mass WIMPs using Voltage-Assisted Calorimetric Ionization Detection in the SuperCDMS Experiment

    Get PDF
    SuperCDMS is an experiment designed to directly detect Weakly Interacting Massive Particles (WIMPs), a favored candidate for dark matter ubiquitous in the Universe. In this paper, we present WIMP-search results using a calorimetric technique we call CDMSlite, which relies on voltage- assisted Luke-Neganov amplification of the ionization energy deposited by particle interactions. The data were collected with a single 0.6 kg germanium detector running for 10 live days at the Soudan Underground Laboratory. A low energy threshold of 170 eVee (electron equivalent) was obtained, which allows us to constrain new WIMP-nucleon spin-independent parameter space for WIMP masses below 6 GeV/c2.Comment: 7 pages, 4 figure
    corecore