91 research outputs found

    MODELLING COLOUR ABSORPTION OF UNDERWATER IMAGES USING SFM-MVS GENERATED DEPTH MAPS

    Get PDF
    Abstract. The problem of colour correction of underwater images concerns not only surveyors, who primarily use images for photogrammetric purposes, but also archaeologists, marine biologists, and many other domains experts whose aim is to study objects and lifeforms underwater. Different methods exist in the literature; some of them provide outstanding results but works involving physical models that take into account additional information and variables (light conditions, depths, camera to objects distances, water properties) that are not always available or can be measured using expensive equipment or calculated using more complicated models. Some other methods have the advantages of working with basically all kinds of dataset, but without considering any geometric information, therefore applying corrections that work only in very generic conditions that most of the time differs from the real-world applications.This paper presents an easy and fast method for restoring the colour information on images captured underwater. The compelling idea is to model light backscattering and absorption variation according to the distance of the surveyed object. This information is always obtainable in photogrammetric datasets, as the model utilises the scene's 3D geometry by creating and using SfM-MVS generated depth maps, which are crucial for implementing the proposed methodology. The results presented visually and quantitatively are promising since they are an excellent compromise to provide a straightforward and easily adaptable workflow to restore the colour information in underwater images

    FOVEON VS BAYER: COMPARISON OF 3D RECONSTRUCTION PERFORMANCES

    Get PDF
    The main idea of this particular study was to validate if the new FOVEON technology implemented by sigma cameras can provide better overall results and outperform the traditional Bayer pattern sensor cameras regarding the radiometric information that records as well as the photogrammetric point cloud quality that can provide. Based on that, the scope of this paper is separated into two evaluations. First task is to evaluate the quality of information reconstructed during de-mosaicking step for Bayer pattern cameras by detecting potential additional colour distortion added during the de-mosaicking step, and second task is the geometric comparisons of point clouds generated by the photos by Bayer and FOVEON sensors against a reference point cloud. The first phase of the study is done using various de-mosaicking algorithms to process various artificial Bayern pattern images and then compare them with reference FOVEON images. The second phase of the study is carried on by reconstructing 3D point clouds of the same objects captured by a Bayer and a FOVEON sensor respectively and then comparing the various point clouds with a reference one, generated by a structured light hand-held scanner. The comparison is separated into two parts, where initially we evaluate five separate point clouds (RGB, Gray, Red, Green, Blue) for each camera sensor per site and then a second comparison is evaluated on colour classified RGB point cloud segments

    Use of polyethylene glycol coatings for optical fibre humidity sensing

    Get PDF
    Humidity induced change in the refractive index and thickness of the polyethylene glycol (PEG) coatings are in situ investigated for a range from 10 to 95%, using an optical waveguide spectroscopic technique. It is experimentally demonstrated that, upon humidity change, the optical and swelling characteristics of the PEG coatings can be employed to build a plastic fibre optic humidity sensor. The sensing mechanism is based on the humidity induced change in the refractive index of the PEG film, which is directly coated onto a polished segment of a plastic optical fibre with dip-coating method. It is observed that PEG, which is a highly hydrophilic material, shows no monotonic linear response to humidity but gives different characteristics for various ranges of humidity levels both in index of refraction and in thickness. It undergoes a physical phase change from a semi-crystal line structure to a gel one at around 80% relative humidity. At this phase change point, a drastic decrease occurs in the index of refraction as well as a drastic increase in the swelling of the PEG film. In addition, PEG coatings are hydrogenated in a vacuum chamber. It is observed that the hydrogen has a preventing effect on the humidity induced phase change in PEG coatings. Finally, the possibility of using PEG coatings in construction of a real plastic fibre optic humidity sensor is discussed. (C) 2008 The Optical Society of Japan

    GEOMATICS AND CIVIL ENGINEERING INNOVATIVE RESEARCH ON HERITAGE: INTRODUCING THE “ENGINEER” PROJECT

    Get PDF
    This paper aims to introduce the concept and objectives of a recently supported European project entitled “Geomatics and Civil Engineering Innovative Research on Heritage”, in short ENGINEER. The ENGINEER project visions to enhance and extend inter- departmental multidisciplinary research activities of the Department of Civil Engineering & Geomatics of the Cyprus University of Technology through coordination and support actions as well as through targeted research activities with the support of European leading institutions. Project tasks aim to fill research multidisciplinary gaps, push, and extend knowledge into new and innovative fields dealing with the monitoring, digitization, visualization, and preservation of ancient monuments and cultural heritage sites, assisting their protection, promotion, and safeguarding
    corecore