519 research outputs found

    Preliminary estimates of radiosonde thermistor errors

    Get PDF
    Radiosonde temperature measurements are subject to errors, not the least of which is the effect of long- and short-wave radiation. Methods of adjusting the daytime temperatures to a nighttime equivalent are used by some analysis centers. Other than providing consistent observations for analysis this procedure does not provide a true correction. The literature discusses the problem of radiosonde temperature errors but it is not apparent what effort, if any, has been taken to quantify these errors. To accomplish the latter, radiosondes containing multiple thermistors with different coatings were flown at Goddard Space Flight Center/Wallops Flight Facility. The coatings employed had different spectral characteristics and, therefore, different adsorption and emissivity properties. Discrimination of the recorded temperatures enabled day and night correction values to be determined for the US standard white-coated rod thermistor. The correction magnitudes are given and a comparison of US measured temperatures before and after correction are compared with temperatures measured with the Vaisala radiosonde. The corrections are in the proper direction, day and night, and reduce day-night temperature differences to less than 0.5 C between surface and 30 hPa. The present uncorrected temperatures used with the Viz radiosonde have day-night differences that exceed 1 C at levels below 90 hPa. Additional measurements are planned to confirm these preliminary results and determine the solar elevation angle effect on the corrections. The technique used to obtain the corrections may also be used to recover a true absolute value and might be considered a valuable contribution to the meteorological community for use as a reference instrument

    Comparative effectiveness of hand scaling by undergraduate dental students following a two-week pre-clinical training course

    Full text link
    BACKGROUND The Bologna reform resulted in a drastic restructuring of pre-clinical training courses at the University of Zurich. The aim of this study was to assess student pre-clinical scaling/root planning skills after just 8.5 hours of manual training. MATERIAL AND METHODS Three consecutive classes of dental students (n = 41; n = 34; n = 48) were tasked with removing lacquer concrement from the maxillary left canine on a typodont using Gracey and universal (Deppeler M23A) curettes. At baseline (prior to instruction), a timed five-minute session of scaling/root planning was undertaken. The second scaling/root planning session was held immediately following training. Eight experienced dental hygienists and eight lay people served as positive and negative controls, using the same instruments and time limit, respectively. Instrumented teeth were collected, scanned and planimetrically analysed for the percentage of tooth surface cleaned. Statistical analyses were performed to assess the dental students' improvement after the training (Wilcoxon signed-rank test) and to compare it to that of laypeople and dental hygienists (Kruskal-Wallis rank sum test followed by Conover's post hoc test). RESULTS At baseline, the dental students' mean scaling scores of the cleaned surfaces were not significantly different than those of laypeople (29.8%, 31.0%, 42% vs 27.9%). However, after 8.5 hours of manual training, the students' ability to clean the maxillary tooth improved significantly and they achieved mean removal values of 61.7%, 79.5% and 76% compared to the 67.4% (P < .001) of the experienced dental hygienists (Tables Tables  and ). There were no statistically significant differences between the scores achieved by students after training and those achieved by experienced dental hygienists. CONCLUSION A shortened pre-clinical training time was sufficient for students to acquire the basic scaling/root planning skills needed in preparation for clinical training. Further research is needed to identify ways to help students consistently reach highest skill levels

    Effect of age on bone mineral density and micro architecture in the radius and tibia of horses: An Xtreme computed tomographic study

    Get PDF
    Background: The effect of age on the bone mineral density and microarchitecture of the equine radius and tibia was investigated. Fifty-six bones from 15 horses aged four to 21 years were used. There were nine geldings and six mares, and none of the horses had any disease influencing bone properties. Xtreme computed tomography was used to evaluate a 9-mm segment of the diaphysis and metaphysis of each bone. The following variables were determined: length of the bone, circumference and diameter in the frontal and sagittal planes in the middle of the bone. Diaphysis: total volume, bone volume, bone volume ratio, slice area, bone area, marrow area, cortical and marrow thickness, bone mineral density, polar moment of inertia of the cortex. Metaphysis: total area, bone area, cortical bone area, cortical thickness, bone mineral density, bone mineral density in the cortex, bone mineral density in the trabecular region, trabecular number, trabecular thickness, trabecular separation, polar moment of inertia of the metaphysis, polar moment of inertia of the cortex of the metaphysis. Results: Bone density and microarchitecture were not affected by breed or gender. However, the microarchitecture varied with the age of the horse; the number of trabeculae decreased significantly and the distance between trabeculae increased significantly with increasing age. There were no significant differences between bones of the left and right limbs or between the radius and tibia. Conclusion: The variables investigated did not differ between geldings and mares. However, there were age-related changes in the microstructure of the bones. Further experimental studies are necessary to determine whether these changes reduce bone strength. Age-related changes in the bones were seen and may explain the higher incidence of fractures and fissures in older horses

    Plaque bei Brackets: Probleme und Lösungen

    Full text link

    Gravity waves in the middle atmosphere during the MaCWAVE winter campaign: evidence of mountain wave critical level encounters

    Get PDF
    Falling sphere and balloon wind and temperature data from the MaCWAVE winter campaign, which was conducted in northern Scandinavia during January&amp;nbsp;2003, are analyzed to investigate gravity wave characteristics in the stratosphere and mesosphere. There were two stratospheric warming events occurring during the campaign, one having a maximum temperature perturbation at ~45 km during 17&amp;ndash;19&amp;nbsp;January, and the other having a maximum perturbation at ~30 km during 24&amp;ndash;27&amp;nbsp;January. The former was a major event, whereas the latter was a minor one. Both warmings were accompanied by upper mesospheric coolings, and during the second warming, the upper mesospheric cooling propagated downward. Falling sphere data from the two salvos on 24&amp;ndash;25&amp;nbsp;January and 28&amp;nbsp;January were analyzed for gravity wave characteristics. Gravity wave perturbations maximized at ~45&amp;ndash;50 km, with a secondary maximum at ~60 km during Salvo&amp;nbsp;1; for Salvo&amp;nbsp;2, wave activity was most pronounced at ~60 km and above. &lt;P style=&quot;line-height: 20px;&quot;&gt; Gravity wave horizontal propagation directions are estimated using the conventional hodographic analysis combined with the S-transform (a Gaussian wavelet analysis method). The results are compared with those from a Stokes analysis. They agree in general, though the former appears to provide better estimates for some cases, likely due to the capability of the S-transform to obtain robust estimates of wave amplitudes and phase differences between different fields. &lt;P style=&quot;line-height: 20px;&quot;&gt; For Salvo&amp;nbsp;1 at ~60 km and above, gravity waves propagated towards the southeast, whereas for Salvo&amp;nbsp;2 at similar altitudes, waves propagated predominantly towards the northwest or west. These waves were found not to be topographic waves. Gravity wave motions at ~45&amp;ndash;50 km in Salvo&amp;nbsp;1 were more complicated, but they generally had large amplitudes, short vertical scales, and their hodographs revealed a northwest-southeast orientation. In addition, the ratios between wave amplitudes and intrinsic phase speeds generally displayed a marked peak at ~45&amp;ndash;50 km and decreased sharply at ~50 km, where the background winds were very weak. These results suggest that these wave motions were most likely topographic waves approaching their critical levels. Waves were more nearly isotropic in the lower stratosphere

    Bone defect development in experimental canine peri-implantitis models: a systematic review

    Full text link
    PURPOSE To provide a systematic overview of preclinical research regarding bone defect formation around different implant surfaces after ligature-induced peri-implantitis models in dogs. Two focused questions were formulated: 'How much bone loss can be expected after a certain time of ligature induced peri-implantitis?' and 'Do different implant types, dog breeds and study protocols differ in their extent of bone loss?' MATERIALS AND METHODS A systematic literature search was conducted on four databases (MEDLINE, Web of Science, EMBASE and Scopus). Observations, which consisted of bone defects measured directly after ligature removal in canine models, were included and analysed. Two approaches were used to analyse the relatively heterogeneous studies that fulfilled the inclusion criteria. First, separate simple linear regressions were calculated for each study and implant surface, for which observations were available across multiple time points. Second, a linear mixed model was specified for the observations at 12 weeks after ligature initiation, and assessing the potential influencing factors on defect depth was explored using lasso regularisation. RESULTS Thirty-six studies with a total of 1082 implants were included after. Bone loss was determined at different time points, either with clinical measurements radiographically or histologically. Different implant groups [e.g. turned, sand-blasted-acid-etched (SLA), titanium-plasma-sprayed (TPS) and other rough surfaces] were assessed and described in the studies. A mean incremental defect depth increase of 0.08 mm (SD: -0.01-0.28 mm) per week was observed. After 12 weeks, the defect depths ranged between 0.7 and 5 mm. Based on the current data set, implant surface could not be statistically identified as an essential factor in defect depth after 12 weeks of ligature-induced peri-implantitis. CONCLUSION Expectable defect depth after a specific time of ligature-induced peri-implantitis can vary robustly. It is currently impossible to delineate apparent differences in bone loss around different implant surfaces

    Bacterial contamination of air and surfaces during dental procedures—An experimental pilot study using Staphylococcus aureus

    Get PDF
    Objective: The oral cavity contains numerous microorganisms, including antimicrobial-resistant bacteria. These microorganisms can be transmitted via respiratory particles from patients to healthcare providers and vice versa during dental care. We evaluated the spread of Staphylococcus aureus during standardized dental procedures using different scaling devices and rinsing solutions. Methods: During systematic therapy for dental biofilm removal (guided biofilm therapy), using an airflow or ultrasound device to a model simulation head. Staphylococcus aureus suspension was injected into the mouth of the model to mimic saliva. Different suction devices (conventional saliva ejector or a prototype) and rising solutions (water or chlorhexidine) were used. To assess contamination with S. aureus, an air-sampling device was placed near the oral cavity and samples of surface areas were collected. Results: S. aureus was only detected by air sampling when the conventional saliva ejector with airflow was used. No growth was observed during treatments with the ultrasonic piezo instrument or the prototype suction device. Notably, a rinsing solution of chlorhexidine digluconate decreased the bacterial load compared to water. Surface contamination was rarely detected (1 of 120 samples). Conclusions: Although our findings indicate potential airborne bacterial transmission during routine prophylactic procedures, specific treatment options during biofilm removal appear to reduce air contamination. These options include ultrasonic piezo devices or the prototype suction device. The use of chlorhexidine reduced the CFU counts of S. aureus detected by air sampling. Surface contamination during dental procedures was a rare occurrence

    Propagation of short-period gravity waves at high-latitudes during the MaCWAVE winter campaign

    Get PDF
    As part of the MaCWAVE (Mountain and Convective Waves Ascending Vertically) winter campaign an all-sky monochromatic CCD imager has been used to investigate the properties of short-period mesospheric gravity waves at high northern latitudes. Sequential measurements of several nightglow emissions were made from Esrange, Sweden, during a limited period from 27&amp;ndash;31&amp;nbsp;January 2003. Coincident wind measurements over the altitude range (~80&amp;ndash;100 km) using two meteor radar systems located at Esrange and Andenes have been used to perform a novel investigation of the intrinsic properties of five distinct wave events observed during this period. Additional lidar and MSIS model temperature data have been used to investigate their nature (i.e. freely propagating or ducted). Four of these extensive wave events were found to be freely propagating with potential source regions to the north of Scandinavia. No evidence was found for strong orographic forcing by short-period waves in the airglow emission layers. The fifth event was most unusual exhibiting an extensive, but much smaller and variable wavelength pattern that appeared to be embedded in the background wind field. Coincident wind measurements indicated the presence of a strong shear suggesting this event was probably due to a large-scale Kelvin-Helmholtz instability
    • …
    corecore