3,980 research outputs found
Characterisation of an analogue liquid for hydrodynamic studies of gas-ionic liquid flows
Ionic liquids are liquid salts at low temperatures (normally less than 100°C). They are powerful solvents with very low vapour pressure. They have great potentials in many applications such as gas absorption and chemical synthesis. However, they are expensive. This limits extensive studies towards establishing phenomenological models. To address this limitation, an analogue liquid, with properties similar to an ionic liquid, has been identified which on the grounds of cost and safety appears to be suitable.
In this paper, the hydrodynamic behaviour of an ionic liquid in a bubble column is compared with those of water and other liquids with similar physical properties. Average gas holdup, bubble coalescence, bubble size and specific interfacial area with different liquids are examined. Gas hold-up was determined by monitoring the change of conductivity between two flush mounted rings. The differences in bubble size and coalescence are revealed by analysing the stills taken from a high speed video camera. The dominant flow pattern in a small diameter column with ionic liquids or other fluids having similar viscosity is slug flow. The small bubbles in the liquid slugs make a smaller contribution to the specific interfacial area than Taylor bubbles. It is observed that Taylor bubbles can coalesce. The hydrodynamics of an ionic liquid in a bubble column can be estimated from that of a fluid with similar physical properties
30S Beam Development and X-ray Bursts
Over the past three years, we have worked on developing a well-characterized
30S radioactive beam to be used in a future experiment aiming to directly
measure the 30S(alpha,p) stellar reaction rate within the Gamow window of Type
I X-ray bursts. The importance of the 30S(alpha,p) reaction to X-ray bursts is
discussed. Given the astrophysical motivation, the successful results of and
challenges involved in the production of a low-energy 30S beam are detailed.
Finally, an overview of our future plans regarding this on-going project are
presented.Comment: 7 pages, 2 figures, 5th European Summer School on Experimental
Nuclear Astrophysics, Santa Tecla, Sicily, September 200
Energy Depandence of Isomeric Yield Rations of Fission Products in 232Th + P System
開始ページ、終了ページ: 冊子体のページ付
Structure of Polyelectrolytes in Poor Solvent
We present simulations on charged polymers in poor solvent. First we
investigate in detail the dilute concentration range with and without imposed
extension constraints. The resulting necklace polymer conformations are
analyzed in detail. We find strong fluctuations in the number of pearls and
their sizes leading only to small signatures in the form factor and the
force-extension relation. The scaling of the peak in the structure factor with
the monomer density shows a pertinent different behavior from good solvent
chains.Comment: 7 pages, 5 figures. submitted to EP
Atomic masses of intermediate-mass neutron-deficient nuclei with relative uncertainty down to 35-ppb via multireflection time-of-flight mass spectrograph
High-precision mass measurements of Cu, Zn, Ga,
Ge, As, Br, Rb, and Sr were performed
utilizing a multireflection time-of-flight mass spectrograph combined with the
gas-filled recoil ion separator GARIS-II. In the case of Ga, a mass
uncertainty of 2.1 keV, corresponding to a relative precision of , was obtained and the mass value is in excellent agreement
with the 2016 Atomic Mass Evaluation. For Ge and Br, where masses
were previously deduced through indirect measurements, discrepancies with
literature values were found. The feasibility of using this device for mass
measurements of nuclides more neutron-deficient side, which have significant
impact on the -process pathway, is discussed.Comment: 15 pages, 6 figures, 1 tabl
Decay Properties of Bh and Db Produced in the Cm + Na Reaction
Decay properties of an isotope Bh and its daughter nucleus Db
produced by the Cm(Na, 5\textit{n}) reaction were studied by
using a gas-filled recoil separator coupled with a position-sensitive
semiconductor detector. Bh was clearly identified from the correlation
of the known nuclide, Db. The obtained decay properties of Bh
and Db are consistent with those observed in the 113 chain,
which provided further confirmation of the discovery of 113.Comment: Accepted for publication in J. Phys. Soc. JPN., to be published in
Vol.78 No.
Prepared to react? Assessing the functional capacity of the primary health care system in rural Orissa, India to respond to the devastating flood of September 2008
Background: Early detection of an impending flood and the availability of countermeasures to deal with it can significantly reduce its health impacts. In developing countries like India, public primary health care facilities are frontline organizations that deal with disasters particularly in rural settings. For developing robust counter reacting systems evaluating preparedness capacities within existing systems becomes necessary. Objective: The objective of the study is to assess the functional capacity of the primary health care system in Jagatsinghpur district of rural Orissa in India to respond to the devastating flood of September 2008. Methods: An onsite survey was conducted in all 29 primary and secondary facilities in five rural blocks (administrative units) of Jagatsinghpur district in Orissa state. A pre-tested structured questionnaire was administered face to face in the facilities. The data was entered, processed and analyzed using STATA® 10. Results: Data from our primary survey clearly shows that the healthcare facilities are ill prepared to handle the flood despite being faced by them annually. Basic utilities like electricity backup and essential medical supplies are lacking during floods. Lack of human resources along with missing standard operating procedures; pre-identified communication and incident command systems; effective leadership; and weak financial structures are the main hindering factors in mounting an adequate response to the floods. Conclusion: The 2008 flood challenged the primary curative and preventive health care services in Jagatsinghpur. Simple steps like developing facility specific preparedness plans which detail out standard operating procedures during floods and identify clear lines of command will go a long way in strengthening the response to future floods. Performance critiques provided by the grass roots workers, like this one, should be used for institutional learning and effective preparedness planning. Additionally each facility should maintain contingency funds for emergency response along with local vendor agreements to ensure stock supplies during floods. The facilities should ensure that baseline public health standards for health care delivery identified by the Government are met in non-flood periods in order to improve the response during floods. Building strong public primary health care systems is a development challenge. The recovery phases of disasters should be seen as an opportunity to expand and improve services and facilities
Exact solution of kinetic analysis for thermally activated delayed fluorescence materials
Research at Kyushu, Kyoto and St Andrews Universities was supported by EPSRC and JSPS Core to Core grants (JSPS Core-to-core Program; EPSRC grant number EP/R035164/1). Authors are also grateful for financial support from the Program for Building Regional Innovation Ecosystems of the Ministry of Education, Culture, Sports, Science and Technology, Japan, JST ERATO Grant JPMJER1305, JSPS KAKENHI JP20H05840, and Kyulux Inc.The photophysical analysis of thermally activated delayed fluorescence (TADF) materials has become instrumental to providing insight into their stability and performance, which is not only relevant for organic light-emitting diodes (OLED), but also for other applications such as sensing, imaging and photocatalysis. Thus, a deeper understanding of the photophysics underpinning the TADF mechanism is required to push materials design further. Previously reported analyses in the literature of the kinetics of the various processes occurring in a TADF material rely on several a priori assumptions to estimate the rate constants for forward and reverse intersystem crossing (ISC and RISC, respectively). In this report, we demonstrate a method to determine these rate constants using a three-state model together with a steady-state approximation and, importantly, no additional assumptions. Further, we derive the exact rate equations, greatly facilitating a comparison of the TADF properties of structurally diverse emitters and providing a comprehensive understanding of the photophysics of these systems.PostprintPostprintPeer reviewe
Detectability of colorectal neoplasia with fluorine-18-2-fluoro-2-deoxy-D-glucose positron emission tomography and computed tomography (FDG-PET/CT)
The purpose of this study was to analyze the detectability of colorectal neoplasia with fluorine-18-2-fluoro-2-deoxy-d-glucose positron emission tomography/computed tomography (FDG-PET/CT).
Data for a total of 492 patients who had undergone both PET/CT and colonoscopy were analyzed. After the findings of PET/CT and colonoscopy were determined independently, the results were compared in each of the six colonic sites examined in all patients. The efficacy of PET/CT was determined using colonoscopic examination as the gold standard.
In all, 270 colorectal lesions 5 mm or more in size, including 70 pathologically confirmed malignant lesions, were found in 172 patients by colonoscopy. The sensitivity and specificity of PET/CT for detecting any of the colorectal lesions were 36 and 98%, respectively. For detecting lesions 11 mm or larger, the sensitivity was increased to 85%, with the specificity remaining consistent (97%). Moreover, the sensitivity for tumors 21 mm or larger was 96% (48/50). Tumors with malignant or high-grade pathology were likely to be positive with PET/CT. A size of 10 mm or smaller [odds ratio (OR) 44.14, 95% confidence interval (95% CI) 11.44-221.67] and flat morphology (OR 7.78, 95% CI 1.79-36.25) were significant factors that were associated with false-negative cases on PET/CT.
The sensitivity of PET/CT for detecting colorectal lesions is acceptable, showing size- and pathology-dependence, suggesting, for the most part, that clinically relevant lesions are detectable with PET/CT. However, when considering PET/CT for screening purposes caution must be exercised because there are cases of false-negative results
Natural history of spontaneous aortic intramural hematoma progression: Six years follow-up with cardiovascular magnetic resonance
We described a 6 years follow-up of a spontaneous aortic intramural hematoma (IMH) with cardiovascular magnetic resonance (CMR) examination. Since multiple factors may play roles in the natural history of IMH, the patient experienced the course of progression, which included hematoma absorption, ulcer-like lesion, aneurysm and limited dissection. The initial and follow-up CMR examination included 3D CE MRA and non-enhanced "bright blood" pulse sequence. The inherent advantage of outstanding contrast with plain scan, which shorten the scan time and avoid potential risk of contrast agent, might make the fast gradient echo sequence as an alternative method when following stable IMH
- …