7,358 research outputs found

    Sterilizable Liquid Propulsion System, Part 1 Final Report, 5 Oct. 1966 - 31 Mar. 1968

    Get PDF
    Exposure of assembled and fueled bipropellant liquid propulsion system to ethylene oxid

    The twisted open string partition function and Yukawa couplings

    Get PDF
    We use the operator formalism to derive the bosonic contribution to the twisted open string partition function in toroidal compactifications. This amplitude describes, for instance, the planar interaction between g+1 magnetized or intersecting D-branes. We write the result both in the closed and in the open string channel in terms of Prym differentials on the appropriate Riemann surface. Then we focus on the g=2 case for a 2-torus. By factorizing the twisted partition function in the open string channel we obtain an explicit expression for the 3-twist field correlator, which is the main ingredient in the computation of Yukawa couplings in D-brane phenomenological models. This provides an alternative method for computing these couplings that does not rely on the stress-energy tensor technique.Comment: 32 pages, 5 figures, Latex; v2: typos correcte

    Implant survival and success rates in patients with risk factors: results from a long-term retrospective study with a 10 to 18 years follow-up

    Get PDF
    OBJECTIVE: Risk factors for implant therapy are represented by all general and local conditions that through various mechanisms can increase either short-term and long-term failure risk. The aim of this study is to assess the implant survival and implant success rates with single and multiple risk factors. PATIENTS AND METHODS: To address the research purpose, a retrospective cohort study was designed and implemented, including a sample of 225 patients with a total of 871 implants placed. The following risk factors were considered: smoking, bruxism, bone augmentation procedures and the presence of load risk (implants with crown/implant relation > 0.8; angulation > 25°; presence of cantilever). Follow-up ranged from 10 years to 18 years (average follow-up 13.6 years). Failures were subdivided into short-term failures, before the prosthetic phase, and long-term failures, after definitive prosthesis. The success criteria published by Albrektsson and Zarb were adopted. A Cox proportional hazard regression model was used to calculate hazard ratio, with a statistically significant p-value <0.05. RESULTS: Out of the 871 implants placed, 138 did not meet the success criteria, (success rate 84.16%), sixty (43.47%) were classified as "early failure" and seventy-eight as "late failure" (56.53%). A total of 70 dental implants were removed, with a survival rate of 91.96%. CONCLUSIONS: The presence of a single risk factor does not imply a marked increase of failure risk. Among the analyzed factors, the one that proved to be the most dangerous was bruxism, even when presented as the only risk factor. Bruxism with load risk proved to be the most dangerous association (success rate 69.23%) and could be included among the absolute contraindications for implant treatment

    A randomized clinical trial about presence of pathogenic microflora and risk of peri-implantitis: comparison of two different types of implant-abutment connections

    Get PDF
    OBJECTIVE: The aim of this in vivo study was to evaluate two different types of implant-abutment connections: screwed connection and cemented connection, analyzing peri-implant bacteria microflora as well as other clinical parameters. PATIENTS AND METHODS: Twenty implants were selected, inserted in 20 patients, 10 with a screwed implant-abutment connection (Group 1) and 10 with a cemented implant-abutment connection (Group 2). The peri-implant microflora was collected, after at least 360 days from the prosthetic rehabilitation, using paper points inserted in peri-implant sulcus for 30 s. Polymerase chain reaction (PCR) Real-time analyzed the presence of 9 bacteria periodontal-pathogens and Candida albicans. RESULTS: Our findings showed that bacteria colonized all Groups analyzed, the average bacterial count was 3.7 E +08 (±1.19) in Group 1, compared to 2.1 E +08 (±0.16) in Group 2; no statistically significant differences were observed (p>0.0.5). In Group 1, however, bacterial colonization of peri-implant sulci was over the pathogenic threshold for 5 bacteria, indicating a high-risk of peri-implantitis. Also in Group 2, results showed a microflora composed by all bacteria analyzed but, in this case, bacterial colonization of peri-implant sulci was over the pathogenic threshold for only 1 bacterium, indicating a lower risk of peri-implantitis. Moreover, clinical parameters (PPD > 3 mm and m SBI > 0) confirmed a greater risk of peri-implantitis in Group 1 compared to Group 2 (p<0.05). CONCLUSIONS: We concluded that, also after only 360 days, implants with screwed connection showed a higher risk of peri-implantitis that implants with cemented connection

    Measuring the Performance of Underplatform Dampers for Turbine Blades by Rotating Laser Doppler Vibrometer

    Get PDF
    Underplatform friction dampers are commonly used to control the vibration level of turbine blades in order to prevent high-cycle fatigue failures. Experimental validation of highly non-linear response predictions obtained from FEM bladed disk models incorporating underplatform dampers models, has proved to be very difficult so as the assessment of the performance of a chosen design. In this paper, the effect of wedgeshaped underplatform dampers on the dynamics of a simple bladed disk under rotating conditions is measured and the effect of the excitation level on the UPDs performances is investigated at different number of the engine order excitation nearby resonance frequencies of the 1st blade bending modes of the system. The measurements are performed with an improved configuration of a rotating test rig, designed with a noncontact magnetic excitation and a non-contact rotating SLDV measurement syste

    Scattering lengths and universality in superdiffusive L\'evy materials

    Full text link
    We study the effects of scattering lengths on L\'evy walks in quenched one-dimensional random and fractal quasi-lattices, with scatterers spaced according to a long-tailed distribution. By analyzing the scaling properties of the random-walk probability distribution, we show that the effect of the varying scattering length can be reabsorbed in the multiplicative coefficient of the scaling length. This leads to a superscaling behavior, where the dynamical exponents and also the scaling functions do not depend on the value of the scattering length. Within the scaling framework, we obtain an exact expression for the multiplicative coefficient as a function of the scattering length both in the annealed and in the quenched random and fractal cases. Our analytic results are compared with numerical simulations, with excellent agreement, and are supposed to hold also in higher dimensionsComment: 6 pages, 8 figure
    • …
    corecore