195 research outputs found
Does shade improve light interception efficiency? A comparison among seedlings from shade-tolerant and -intolerant temperate deciduous tree species
• Here, we tested two hypotheses: shading increases light interception efficiency (LIE) of broadleaved tree seedlings, and shade-tolerant species exhibit larger LIEs than do shade-intolerant ones. The impact of seedling size was taken into account to detect potential size-independent effects on LIE. LIE was defined as the ratio of mean light intercepted by leaves to light intercepted by a horizontal surface of equal area. • Seedlings from five species differing in shade tolerance (Acer saccharum, Betula alleghaniensis, A. pseudoplatanus, B. pendula, Fagus sylvatica) were grown under neutral shading nets providing 36, 16 and 4% of external irradiance. Seedlings (1- and 2-year-old) were three-dimensionally digitized, allowing calculation of LIE. • Shading induced dramatic reduction in total leaf area, which was lowest in shade-tolerant species in all irradiance regimes. Irradiance reduced LIE through increasing leaf overlap with increasing leaf area. There was very little evidence of significant size-independent plasticity of LIE. • No relationship was found between the known shade tolerance of species and LIE at equivalent size and irradiance
Managing understory light conditions in boreal mixedwoods through variation in the intensity and spatial pattern of harvest: A modelling approach
In the context of partial harvesting, adequately managing post-harvest light conditions are essential to obtain a desired composition of tree species regeneration. The objective of this study was to determine how varying the intensity and spatial pattern of harvest would affect understory light conditions in boreal mixedwood stands of northwestern Quebec using the spatially explicit SORTIE-ND light model. The model was evaluated based on comparisons of observed and predicted light levels in both mapped and un-mapped plots. In mapped plots, reasonably accurate predictions of the overall variation in light levels were obtained, but predictions tended to lack spatial precision. In un-mapped plots, SORTIE-ND accurately predicted stand-level mean GLI (Gap Light Index) under a range of harvest intensities. The model was then used to simulate nine silvicultural treatments based on combinations of three intensities of overstory removal (30%, 45% and 60% of basal area) and three harvest patterns (uniform, narrow strips, large gaps). Simulations showed that increasing overstory removal had less impact on light conditions with uniform harvests, and a more marked effect with more aggregated harvest patterns. Whatever the harvest intensity, uniform cuts almost never created high light conditions (GLI > 50%). Gap cuts, on the other hand, resulted in up to 40% of microsites receiving GLI > 50%. Our results suggest that either a 30% strip or gap cut or a 45–60% uniform partial harvest could be used to accelerate the transition from an aspen dominated composition to a mixedwood stand because both types of cut generate the greatest proportion of moderately low light levels (e.g., 15–40% GLI). These light levels tend to favour an accelerated growth response among shade-tolerant conifers, while preventing excessive recruitment of shade-intolerant species. A better understanding of how spatial patterns of harvest interact with tree removal intensity to affect understory light conditions can provide opportunities for designing silvicultural prescriptions that are tailored to species’ traits and better suited to meet a variety of management objectives
Structure-dependent amplification for denoising and background correction in Fourier ptychographic microscopy
Fourier Ptychographic Microscopy (FPM) allows high resolution imaging using iterative phase retrieval to recover an estimate of the complex object from a series of images captured under oblique illumination. FPM is particularly sensitive to noise and uncorrected background signals as it relies on combining information from brightfield and noisy darkfield (DF) images. In this article we consider the impact of different noise sources in FPM and show that inadequate removal of the DF background signal and associated noise are the predominant cause of artefacts in reconstructed images. We propose a simple solution to FPM background correction and denoising that outperforms existing methods in terms of image quality, speed and simplicity, whilst maintaining high spatial resolution and sharpness of the reconstructed image. Our method takes advantage of the data redundancy in real space within the acquired dataset to boost the signal-to-background ratio in the captured DF images, before optimally suppressing background signal. By incorporating differentially denoised images within the classic FPM iterative phase retrieval algorithm, we show that it is possible to achieve efficient removal of background artefacts without suppression of high frequency information. The method is tested using simulated data and experimental images of thin blood films, bone marrow and liver tissue sections. Our approach is non-parametric, requires no prior knowledge of the noise distribution and can be directly applied to other hardware platforms and reconstruction algorithms making it widely applicable in FPM
Histological and cytological imaging using Fourier ptychographic microscopy
Structural imaging using light microscopy is a cornerstone of histology and cytology. However, the utility of the optical microscope for diagnostic imaging is limited by the fundamental tradeoff between the field of view and spatial resolution and a reliance on exogenous dyes to generate sufficient image contrast. Fourier Ptychographic Microscopy (FPM) is a complex imaging modality with the potential to overcome these limitations by recovering high-resolution images of sample amplitude and phase from a set of low-resolution raw images captured under inclined illumination. In this article we explore the application of FPM to clinical imaging using a simple, low-cost FPM system and simulated and experimental data to explore the influence of both image acquisition parameters and hardware configuration on image quality and imaging throughput. The practical performance of the method is investigated by imaging peripheral blood films and histological tissue sections. We find that, at the cost of increased computational complexity, FPM increases the information capture capacity of the optical microscope significantly, allowing label-free examination and quantification of features such as tissue and cell morphology over large sample areas
Digital refocusing and extended depth of field reconstruction in Fourier ptychographic microscopy
Fourier ptychography microscopy (FPM) is a recently developed microscopic imaging method that allows the recovery of a high-resolution complex image by combining a sequence of bright and darkfield images acquired under inclined illumination. The capacity of FPM for high resolution imaging at low magnification makes it particularly attractive for applications in digital pathology which require imaging of large specimens such as tissue sections and blood films. To date most applications of FPM have been limited to imaging thin samples, simplifying both image reconstruction and analysis. In this work we show that, for samples of intermediate thickness (defined here as less than the depth of field of a raw captured image), numerical propagation of the reconstructed complex field allows effective digital refocusing of FPM images. The results are validated by comparison against images obtained with an equivalent high numerical aperture objective lens. We find that post reconstruction refocusing (PRR) yields images comparable in quality to adding a defocus term to the pupil function within the reconstruction algorithm, while reducing computing time by several orders of magnitude. We apply PRR to visualize FPM images of Giemsa-stained peripheral blood films and present a novel image processing pipeline to construct an effective extended depth of field image which optimally displays the 3D sample structure in a 2D image. We also show how digital refocusing allows effective correction of the chromatic focus shifts inherent to the low magnification objective lenses used in FPM setups, improving the overall quality of color FPM images
Depth-resolved local reflectance spectra measurements in full-field optical coherence tomography
Full-field optical coherence tomography (FF-OCT) is a widely used technique for applications such as biological imaging, optical metrology, and materials characterization, providing structural and spectral information. By spectral analysis of the backscattered light, the technique of spectroscopic-OCT enables the differentiation of structures having different spectral properties, but not the determination of their reflectance spectrum. For surface measurements, this can be achieved by applying a Fourier transform to the interferometric signals and using an accurate calibration of the optical system. An extension of this method is reported for local spectroscopic characterization of transparent samples and in particular for the determination of depth-resolved reflectance spectra of buried interfaces. The correct functioning of the method is demonstrated by comparing the results with those obtained using a program based on electromagnetic matrix methods for stratified media. Experimental measurements of spatial resolutions are provided to demonstrate the smallest structures that can be characterized
Optical mesoscopy, machine learning and computational microscopy enable high information content diagnostic imaging of blood films
Automated image-based assessment of blood films has tremendous potential to support clinical haematology within overstretched healthcare systems. To achieve this, efficient and reliable digital capture of the rich diagnostic information contained within a blood film is a critical first step. However, this is often challenging, and in many cases entirely unfeasible, with the microscopes typically used in haematology due to the fundamental trade-off between magnification and spatial resolution. To address this, we investigated three state-of-the-art approaches to microscopic imaging of blood films which leverage recent advances in optical and computational imaging and analysis to increase the information capture capacity of the optical microscope: optical mesoscopy, which uses a giant microscope objective (Mesolens) to enable high resolution imaging at low magnification; Fourier ptychographic microscopy, a computational imaging method which relies on oblique illumination with a series of LEDs to capture high resolution information; and deep neural networks which can be trained to increase the quality of low magnification, low resolution images. We compare and contrast the performance of these techniques for blood film imaging for the exemplar case of Giemsa-stained peripheral blood smears. Using computational image analysis and shape-based object classification we demonstrate their use for automated analysis of red blood cell morphology and visualization and detection of small blood borne parasites such as the malarial parasite Plasmodium falciparum. Our results demonstrate that these new methods greatly increase the information capturing capacity of the light microscope with transformative potential for haematology and more generally across digital pathology. This article is protected by copyright. All rights reserved
Depth-resolved local reflectance spectra measurements in full-field optical coherence tomography
Full-field optical coherence tomography (FF-OCT) is a widely used technique for applications such as biological imaging, optical metrology, and materials characterization, providing structural and spectral information. By spectral analysis of the backscattered light, the technique of spectroscopic-OCT enables the differentiation of structures having different spectral properties, but not the determination of their reflectance spectrum. For surface measurements, this can be achieved by applying a Fourier transform to the interferometric signals and using an accurate calibration of the optical system. An extension of this method is reported for local spectroscopic characterization of transparent samples and in particular for the determination of depth-resolved reflectance spectra of buried interfaces. The correct functioning of the method is demonstrated by comparing the results with those obtained using a program based on electromagnetic matrix methods for stratified media. Experimental measurements of spatial resolutions are provided to demonstrate the smallest structures that can be characterized
- …
