182 research outputs found

    A Robotized Raspberry-Based System for Pothole 3D Reconstruction and Mapping

    Get PDF
    Repairing potholes is a task for municipalities to prevent serious road user injuries and vehicle damage. This study presents a low-cost, high-performance pothole monitoring system to maintain urban roads. The authors developed a methodology based on photogrammetry techniques to predict the pothole's shape and volume. A collection of overlapping 2D images shot by a Raspberry Pi Camera Module 3 connected to a Raspberry Pi 4 Model B has been used to create a pothole 3D model. The Raspberry-based configuration has been mounted on an autonomous and remote-controlled robot (developed in the InfraROB European project) to reduce workers' exposure to live traffic in survey activities and automate the process. The outputs of photogrammetry processing software have been validated through laboratory tests set as ground truth; the trial has been conducted on a tile made of asphalt mixture, reproducing a real pothole. Global Positioning System (GPS) and Geographical Information System (GIS) technologies allowed visualising potholes on a map with information about their centre, volume, backfill material, and an associated image. Ten on-site tests validated that the system works in an uncontrolled environment and not only in the laboratory. The results showed that the system is a valuable tool for monitoring road potholes taking into account construction workers' and road users' health and safety

    Metal Nanoparticles Deposited on Porous Silicon Templates as Novel Substrates for SERS

    Get PDF
    In this paper, results on preparation of stable and uniform SERS solid substrates using macroporous silicon (pSi) with deposited silver and gold are presented. Macroporous silicon is produced by anodisation of p-type silicon in hydrofluoric acid. The as prepared pSi is then used as a template for Ag and Au depositions. The noble metals were deposited in three different ways: by immersion in silver nitrate solution, by drop-casting silver colloidal solution and by pulsed laser ablation (PLA). Substrates obtained by different deposition processes were evaluated for SERS efficiency using methylene blue (MB) and rhodamine 6G (R6G) at 514.5, 633 and 785 nm. Using 514.5 nm excitation and R6G the limits of detection (LOD) for macroporous Si samples with noble metal nanostructures obtained by immersion of pSi sample in silver nitrate solution and by applying silver colloidal solution to pSi template were 10–9 M and 10–8 M respectively. Using 633 nm laser and MB the most noticeable SERS activity gave pSi samples ablated with 30000 and 45000 laser pulses where the LODs of 10–10 M were obtained. The detection limit of 10–10 M was also reached for 4 mA cm–2-15 min pSi sample, silver ablated with 30000 pulses. Macroporous silicon proved to be a good base for the preparation of SERS substrates

    A Hypothetical New Challenging Use for Indocyanine Green Fluorescence during Laparoscopic Appendectomy: A Mini-Series of Our Experience and Literary Review

    Get PDF
    Laparoscopic appendectomy (LA) is a well-standardized surgical procedure, but there are still controversies about the different devices to be used for the appendiceal stump closure and the related postoperative complications. Indocyanine green (ICG) fluorescence angiography (FA) has already been shown to be helpful in elective and emergency surgery, providing intraoperative information on tissue and organ perfusion, thus guiding the surgical decisions and the technical strategies. According to these two aspects, we report a mini-series of the first five patients affected by gangrenous and flegmonous acute appendicitis intraoperatively evaluated with ICG-FA during LA. The patients were admitted to the Emergency Department with an usual range of symptoms for acute appendicitis. The patients were successfully managed by fully LA with the help of a new hypothetical challenging use of ICG-FA

    Asfalti tappabuche e Green Deal

    Get PDF
    This article presents the first results of a study conducted as part of the european research project InfraROB, whose aim is to increase the safety of workers and road users at road maintenance sites. In particular, as part of the project, a system for repairing small potholes by means of an autonomous device is currently being studied. A 3D printer will be installed on this device in order to extrude a mixture suitable for the pothole to be repaired, without the prior cleaning and compaction of the backfill. In particular, this article presents the laboratory and in situ study aimed at defining the optimal characteristics for the mixture to be used to power the 3D printer. Grain size, Marshall stability, void content, indirect tensile strength and material loss were studied in the laboratory using the Cantabro test. These characteristics were evaluated by varying the additive content in the range of 1.5-3.5 per cent and the water content in the range of 3.1-5%. The maximum aggregate size was limited to 8 mm, because the InfraROB project only deals with the repair of small potholes, with a maximum size of 5 cm depth and 20 cm diameter. From the point of view of sustainability, the technology involves the use of 100% rejuvenated RAP (Iterlene ACF 1000 HP Green) with blending at room temperature. A total of eight mixtures were tested. Laboratory tests gave very good results in terms of indirect tensile strength, Marshall stability and particle loss; the mixture proved to be very stable during in-situ tests. Other cold asphalt mixtures are still being studied within the InfraROB project, but at the moment, the mixture presented in this article seems to meet all the requirements of consistency, homogeneity, fluidity and internal structure necessary to be used with a 3D printer

    IL15RA and SMAD3 Genetic Variants Predict Overall Survival in Metastatic Colorectal Cancer Patients Treated with FOLFIRI Therapy: A New Paradigm

    Get PDF
    Simple SummaryThere is an increasing scientific interest in the study of the interaction between the immune system and drugs in cancer that can affect the efficacy of an anti-cancer treatment. This study was undertaken to better understand if the genetic characteristic of a cancer patient's immune system can predict the tumor response to the treatment and the duration of survival. The topic was studied on 335 metastatic colorectal cancer patients treated with a first-line chemotherapy (FOLFIRI regimen, irinotecan-5-fluorouracil-leucovorin). The research highlighted two markers, IL15RA-rs7910212 and SMAD3-rs7179840, significantly associated with the patient's survival. When considering IL15RA-rs7910212 and SMAD3-rs7179840 in combination with other two genetic markers previously investigated (NR1I2-rs1054190, VDR-rs7299460), we built up a highly predictive genetic score of survival. The herein identified markers must be further validated, but still represent good candidates to understand how much a patient with a metastatic colorectal cancer can benefit from a chemotherapy with FOLFIRI regimen.A new paradigm in cancer chemotherapy derives from the interaction between chemotherapeutics, including irinotecan and 5-fluorouracil (5-FU), and the immune system. The patient's immune response can modulate chemotherapy effectiveness, and, on the other hand, chemotherapeutic agents can foster tumor cell immunogenicity. On these grounds, the analysis of the cancer patients' immunogenetic characteristics and their effect on survival after chemotherapy represent a new frontier. This study aims to identify genetic determinants in the immuno-related pathways predictive of overall survival (OS) after FOLFIRI (irinotecan, 5-FU, leucovorin) therapy. Two independent cohorts comprising a total of 335 patients with metastatic colorectal cancer (mCRC) homogeneously treated with first-line FOLFIRI were included in the study. The prognostic effect of 192 tagging genetic polymorphisms in 34 immune-related genes was evaluated using the bead array technology. The IL15RA rs7910212-C allele was associated with worse OS in both discovery (HR: 1.57, p = 0.0327, Bootstrap p-value = 0.0280) and replication (HR: 1.71, p = 0.0411) cohorts. Conversely, SMAD3 rs7179840-C allele was associated with better OS in both discovery (HR: 0.65, p = 0.0202, Bootstrap p-value = 0.0203) and replication (HR: 0.61, p = 0.0216) cohorts. A genetic prognostic score was generated integrating IL15RA-rs7910212 and SMAD3-rs7179840 markers with inflammation-related prognostic polymorphisms we previously identified in the same study population (i.e., PXR [NR1I2]-rs1054190, VDR-rs7299460). The calculated genetic score successfully discriminated patients with different survival probabilities (p < 0.0001 log-rank test). These findings provide new insight on the prognostic value of genetic determinants, such as IL15RA and SMAD3 markers, and could offer a new decision tool to improve the clinical management of patients with mCRC receiving FOLFIRI

    Clinically integrated neuroanatomy modules using neurosurgery and intraoperative MRI/DTI tractography: their contribution to long-term retention of neuroanatomical knowledge

    Get PDF
    Neuroanatomy is often considered the part of the human anatomy syllabus students find hardest to study. To motivate them and boost their learning, clinical cases and neurosurgical images, mainly DTI tractographies produced using an intraoperative magnetic resonance imaging apparatus (MRI/DTI), were presented and discussed during integrated second-year neuroanatomy, neuroradiology and neurosurgery lectures over the five-year 2007-2012 period. Anonymous questionnaires, rated on the Likert scale, showed that the students appreciated this teaching procedure. The academic performance (exam marks for neuroanatomy) of those who attended all the integrated lectures, was slightly, though significantly higher than for students who attended the lectures only occasionally or not at all (p=0.04). Moreover, significantly better results were obtained at the 2012 national progress test (focusing on morphology) by students who attended the MRI/DTI-assisted lectures, compared to those who did so in part or not at all and compared to the national average. These results were obtained by students attending the second, third and, in particular, the fourth, fifth and sixth year (p≤0.0001) courses during the five above-mentioned academic years. The early study of real medical cases, including the relative surgical and post-operative phases, if illustrated by a good collaborative interdisciplinary team, can help direct the students positively towards their future professional reality, without any extra expense to the university. In conclusion, interactive learning tools, like our intraoperative MRI/DTI, motivate students and enhance their learning of neuroanatomy. Most probably it improves long-term retention, which appears to prove helpful during the clinical phase of their undergraduate careers

    Phantom validation of quantitative Y-90 PET/CT based dosimetry in liver radioembolisation

    Get PDF
    Background PET/CT has recently been shown to be a viable alternative to traditional post-infusion imaging methods providing good quality images of 90Y-laden microspheres after selective internal radiation therapy (SIRT). In the present paper, first we assessed the quantitative accuracy of 90Y-PET using an anthropomorphic phantom provided with lungs, liver, spine, and a cylindrical homemade lesion located into the hepatic compartment. Then, we explored the accuracy of different computational approaches on dose calculation, including (I) direct Monte Carlo radiation transport using Raydose, (II) Kernel convolution using Philips Stratos, (III) local deposition algorithm, (IV) Monte Carlo technique (MCNP) considering a uniform activity distribution, and (V) MIRD (Medical Internal Radiation Dose) analytical approach. Finally, calculated absorbed doses were compared with those obtained performing measurements with LiF:Mg,Cu,P TLD chips in a liquid environment. Results Our results indicate that despite 90Y-PET being likely to provide high-resolution images, the 90Y low branch ratio, along with other image-degrading factors, may produce non-uniform activity maps, even in the presence of uniform activity. A systematic underestimation of the recovered activity, both for the tumor insert and for the liver background, was found. This is particularly true if no partial volume correction is applied through recovery coefficients. All dose algorithms performed well, the worst case scenario providing an agreement between absorbed dose evaluations within 20%. Average absorbed doses determined with the local deposition method are in excellent agreement with those obtained using the MIRD and the kernel-convolution dose calculation approach. Finally, absorbed dose assessed with MC codes are in good agreement with those obtained using TLD in liquid solution, thus confirming the soundness of both calculation approaches. This is especially true for Raydose, which provided an absorbed dose value within 3% of the measured dose, well within the stated uncertainties. Conclusions Patient-specific dosimetry is possible even in a scenario with low true coincidences and high random fraction, as in 90Y–PET imaging, granted that accurate absolute PET calibration is performed and acquisition times are sufficiently long. Despite Monte Carlo calculations seeming to outperform all dose estimation algorithms, our data provide a strong argument for encouraging the use of the local deposition algorithm for routine 90Y dosimetry based on PET/CT imaging, due to its simplicity of implementation
    • …
    corecore