14 research outputs found

    Caries progression in non-cavitated fissures after infiltrant application: a 3-year follow-up of a randomized controlled clinical trial

    Get PDF
    Objectives To evaluate the efficacy of a conservative treatment to prevent the progression of caries using an infiltrant on non-cavitated pit and fissures. Material and Methods This controlled clinical trial selected 23 volunteers with clinically and radiographically non-cavitated occlusal caries among patients presenting a “rather low” to “very high” caries risk. Eighty-six teeth were randomly divided into two experimental groups: teeth receiving a commercial pit-and-fissure sealant (Alpha Seal-DFL) and contralateral teeth receiving Icon infiltrant (DMG). Caries progression was monitored by clinical (laser fluorescence caries detection) and radiographic examination at 12-month intervals over a period of 3 years of monitored caries progression. Probing the sealing materials to detect areas of retention was also used to evaluate marginal integrity. Results Statistical analysis showed no difference in caries progression using laser fluorescence caries detection when both materials were compared, regardless of the evaluation times (p>;0.05). No significance was observed when the marginal sealant integrity of both materials was compared, regardless of the evaluation time (

    Water interaction and bond strength to dentin of dye-labelled adhesive as a function of the addition of rhodamine B

    Get PDF
    Objective This study investigated the effect of the fluorescent dye rhodamine B (RB) for interfacial micromorphology analysis of dental composite restorations on water sorption/solubility (WS/WSL) and microtensile bond strength to dentin (µTBS) of a 3-step total etch and a 2-step self-etch adhesive system. Material and Methods The adhesives Adper Scotchbond Multi-Purpose (MP) and Clearfil SE Bond (SE) were mixed with 0.1 mg/mL of RB. For the WS/WSL tests, cured resin disks (5.0 mm in diameter x 0.8 mm thick) were prepared and assigned into four groups (n=10): MP, MP-RB, SE, and SE-RB. For µTBS assessment, extracted human third molars (n=40) had the flat occlusal dentin prepared and assigned into the same experimental groups (n=10). After the bonding and restoration procedures, specimens were sectioned in rectangular beams, stored in water and tested after seven days or after 12 months. The failure mode of fractured specimens was qualitatively evaluated under optical microscope (x40). Data from WS/WSL and µTBS were assessed by one-way and three-way ANOVA, respectively, and Tukey’s test (α=5%). Results RB increased the WSL of MP and SE. On the other hand, WS of both MP and SE was not affected by the addition of RB. No significance in µTBS between MP and MP-RB for seven days or one year was observed, whereas for SE a decrease in the µTBS means occurred in both storage times. Conclusions RB should be incorporated into non-simplified DBSs with caution, as it can interfere with their physical-mechanical properties, leading to a possible misinterpretation of bonded interface

    Regenerative and Protective Effects on Dental Tissues of a Fluoride–Silicon-Rich Toothpaste Associated with a Calcium Booster: An <i>In Vitro</i> Study

    No full text
    Calcium boosters have been used as a supplement for fluoride toothpastes to repair the dental tissues and reduce dentin permeability. This in vitro study aimed to characterize the regenerative and protective effects of the treatment of dental tissues with a fluoride–silicon-rich toothpaste associated with a calcium booster. Bovine enamel and dentin blocks (n = 5) were obtained (4 × 4 × 6 mm). A fluoride–silicon-rich toothpaste and a calcium booster were used to brush the enamel and dentin both immediately and five days afterwards. The outcomes were then compared to those of the untreated control group. After that, the specimens were cross-sectioned. SEM was used to evaluate the micromorphology of the surface and cross-section. Energy-dispersive X-ray spectroscopy (EDS) was used to determine the elemental analyses (weight%). After treatment for 5 days with a booster/silicon-rich toothpaste, EDS analysis demonstrated that it induced a significant mineral change. It was also able to form a protective silicon-enriched mineral layer on both enamel and dentin surfaces. It was demonstrated in vitro that a fluoride–silicon-rich toothpaste associated with a calcium booster regenerates the dental tissues, remineralizing the enamel structure and occluding the dentin tubules

    Caries progression in non-cavitated fissures after infiltrant application: a 3-year follow-up of a randomized controlled clinical trial

    No full text
    Abstract Objectives To evaluate the efficacy of a conservative treatment to prevent the progression of caries using an infiltrant on non-cavitated pit and fissures. Material and Methods This controlled clinical trial selected 23 volunteers with clinically and radiographically non-cavitated occlusal caries among patients presenting a “rather low” to “very high” caries risk. Eighty-six teeth were randomly divided into two experimental groups: teeth receiving a commercial pit-and-fissure sealant (Alpha Seal-DFL) and contralateral teeth receiving Icon infiltrant (DMG). Caries progression was monitored by clinical (laser fluorescence caries detection) and radiographic examination at 12-month intervals over a period of 3 years of monitored caries progression. Probing the sealing materials to detect areas of retention was also used to evaluate marginal integrity. Results Statistical analysis showed no difference in caries progression using laser fluorescence caries detection when both materials were compared, regardless of the evaluation times (p>0.05). No significance was observed when the marginal sealant integrity of both materials was compared, regardless of the evaluation time (p0.05). SEM analysis exhibited a more homogeneous sealing for the infiltrant than obtained by the sealant. Conclusions The infiltrant was effective to prevent the caries progression in non-cavitated pit-and-fissures after 3 years of clinical evaluation, comparable with the conventional sealant. The infiltrant also presented better results in terms of caries progression at the 3-year evaluation time using the radiographic analysis

    Water interaction and bond strength to dentin of dye-labelled adhesive as a function of the addition of rhodamine B

    No full text
    ABSTRACT Objective This study investigated the effect of the fluorescent dye rhodamine B (RB) for interfacial micromorphology analysis of dental composite restorations on water sorption/solubility (WS/WSL) and microtensile bond strength to dentin (µTBS) of a 3-step total etch and a 2-step self-etch adhesive system. Material and Methods The adhesives Adper Scotchbond Multi-Purpose (MP) and Clearfil SE Bond (SE) were mixed with 0.1 mg/mL of RB. For the WS/WSL tests, cured resin disks (5.0 mm in diameter x 0.8 mm thick) were prepared and assigned into four groups (n=10): MP, MP-RB, SE, and SE-RB. For µTBS assessment, extracted human third molars (n=40) had the flat occlusal dentin prepared and assigned into the same experimental groups (n=10). After the bonding and restoration procedures, specimens were sectioned in rectangular beams, stored in water and tested after seven days or after 12 months. The failure mode of fractured specimens was qualitatively evaluated under optical microscope (x40). Data from WS/WSL and µTBS were assessed by one-way and three-way ANOVA, respectively, and Tukey’s test (α=5%). Results RB increased the WSL of MP and SE. On the other hand, WS of both MP and SE was not affected by the addition of RB. No significance in µTBS between MP and MP-RB for seven days or one year was observed, whereas for SE a decrease in the µTBS means occurred in both storage times. Conclusions RB should be incorporated into non-simplified DBSs with caution, as it can interfere with their physical-mechanical properties, leading to a possible misinterpretation of bonded interface
    corecore