68 research outputs found

    Effects of increased afterload on left ventricular performance and mechanical efficiency are not baroreflex-mediated

    Full text link
    peer reviewedObjective: To assess baroreflex intervention during increase in left ventricular afterload, we compared the effects of aortic banding on the intact cardiovascular system and under hexamethonium infusion. Methods: Six open-chest pigs, instrumented for measurement of aortic pressure and flow, left ventricular pressure and volume, were studied under pentobarbital-sufentanil anesthesia. Vascular arterial properties were estimated with a four-element windkessel model. Left ventricular contractility was assessed by the slope of end-systolic pressure-volume relationship. Results: The effects of aortic banding on mechanical aortic properties were unaffected by autonomic nervous system inhibition. However, increase in peripheral arterial vascular resistance and in heart rate were prevented by hexamethonium. Aortic banding increased left ventricular contractility and stroke work. Left ventricular-arterial coupling remained unchanged, but mechanical efficiency was impaired. These ventricular changes were independent of baroreflex integrity. Conclusions: Our results demonstrate that an augmentation in afterload has a composite effect on left ventricular function. Left ventricular performance is increased, as demonstrated by increase in contractility and stroke work, but mechanical efficiency is decreased. These changes are observed independently of baroreflex integrity. Such mechanisms of autoregulation, independent of the autonomic nervous system, are of paramount importance in heart transplant patients. (C) 2003 Elsevier B.V. All fights reserved

    Comparison between single-beat and multiple-beat methods for estimation of right ventricular contractility.

    Full text link
    OBJECTIVE: It was investigated whether pharmacologically induced changes in right ventricular contractility can be detected by a so-called "single-beat" method that does not require preload reduction. DESIGN: Prospective animal research. SETTING: Laboratory at a large university medical center. SUBJECTS: Eight anesthetized pigs. INTERVENTIONS: End-systolic elastance values obtained by a recently proposed single-beat method (Eessb) were compared with those obtained using the reference multiple-beat method (Eesmb). MEASUREMENTS AND MAIN RESULTS: Administration of dobutamine increased Eesmb from 1.6 +/- 0.3 to 3.8 +/- 0.5 mm Hg/mL (p =.001), whereas there was only a trend toward an increase in Eessb from 1.5 +/- 0.2 to 1.7 +/- 0.4 mm Hg/mL. Esmolol decreased Eesmb from 1.7 +/- 0.3 to 1.1 +/- 0.2 mm Hg/mL (p =.006), whereas there was only a trend for a decrease in Eessb from 1.5 +/- 0.2 to 1.3 +/- 0.1. CONCLUSIONS: The present method using single-beat estimation to assess right ventricular contractility does not work as expected, since it failed to detect either increases or decreases in right ventricular contractility induced by pharmacologic interventions.Peer reviewe

    Parsonage-Turner Syndrome as a Rare Extrahepatic Complication of Hepatitis E Infection

    Get PDF
    Parsonage-Turner syndrome, also known as neuralgic amyotrophy, is a rare disorder characterized by painful clinical manifestations mainly involving the upper limbs. This syndrome seems to be triggered, among other factors, by some viral infections, although its pathophysiology remains unclear. Moreover, it has rarely been related to hepatitis E virus infection. We report the case of a 33-year-old man who was diagnosed with Parsonage-Turner syndrome following acute hepatitis E infection

    Mathematical multi-scale model of the cardiovascular system including mitral valve dynamics. Application to ischemic mitral insufficiency

    Get PDF
    Valve dysfunction is a common cardiovascular pathology. Despite significant clinical research, there is little formal study of how valve dysfunction affects overall circulatory dynamics. Validated models would offer the ability to better understand these dynamics and thus optimize diagnosis, as well as surgical and other interventions. A cardiovascular and circulatory system (CVS) model has already been validated in silico, and in several animal model studies. It accounts for valve dynamics using Heaviside functions to simulate a physiologically accurate “open on pressure, close on flow” law. However, it does not consider real-time valve opening dynamics and therefore does not fully capture valve dysfunction, particularly where the dysfunction involves partial closure. This research describes an updated version of this previous closed-loop CVS model that includes the progressive opening of the mitral valve, and is defined over the full cardiac cycle. Simulations of the cardiovascular system with healthy mitral valve are performed, and, the global hemodynamic behaviour is studied compared with previously validated results. The error between resulting pressure-volume (PV) loops of already validated CVS model and the new CVS model that includes the progressive opening of the mitral valve is assessed and remains within typical measurement error and variability. Simulations of ischemic mitral insufficiency are also performed. Pressure-Volume loops, transmitral flow evolution and mitral valve aperture area evolution follow reported measurements in shape, amplitude and trends. The resulting cardiovascular system model including mitral valve dynamics provides a foundation for clinical validation and the study of valvular dysfunction in vivo. The overall models and results could readily be generalised to other cardiac valves

    Decision-based interactive model to determine re-opening conditions of a large university campus in Belgium during the first COVID-19 wave

    Full text link
    peer reviewedBackground The role played by large-scale repetitive SARS-CoV-2 screening programs within university populations interacting continuously with an urban environment, is unknown. Our objective was to develop a model capable of predicting the dispersion of viral contamination among university populations dividing their time between social and academic environments. Methods Data was collected through real, large-scale testing developed at the University of Liège, Belgium, during the period Sept. 28th-Oct. 29th 2020. The screening, offered to students and staff (n = 30,000), began 2 weeks after the re-opening of the campus but had to be halted after 5 weeks due to an imposed general lockdown. The data was then used to feed a two-population model (University + surrounding environment) implementing a generalized susceptible-exposed-infected-removed compartmental modeling framework. Results The considered two-population model was sufficiently versatile to capture the known dynamics of the pandemic. The reproduction number was estimated to be significantly larger on campus than in the urban population, with a net difference of 0.5 in the most severe conditions. The low adhesion rate for screening (22.6% on average) and the large reproduction number meant the pandemic could not be contained. However, the weekly screening could have prevented 1393 cases (i.e. 4.6% of the university population; 95% CI: 4.4–4.8%) compared to a modeled situation without testing. Conclusion In a real life setting in a University campus, periodic screening could contribute to limiting the SARS-CoV-2 pandemic cycle but is highly dependent on its environment

    Arterial dP/dtmax accurately reflects left ventricular contractility during shock when adequate vascular filling is achieved

    Get PDF
    Background: Peak first derivative of femoral artery pressure (arterial dP/dt max) derived from fluid-filled catheter remains questionable to assess left ventricular (LV) contractility during shock. The aim of this study was to test if arterial dP/dt maxis reliable for assessing LV contractility during various hemodynamic conditions such as endotoxin-induced shock and catecholamine infusion.Methods: Ventricular pressure-volume data obtained with a conductance catheter and invasive arterial pressure obtained with a fluid-filled catheter were continuously recorded in 6 anaesthetized and mechanically ventilated pigs. After a stabilization period, endotoxin was infused to induce shock. Catecholamines were transiently administrated during shock. Arterial dP/dt maxwas compared to end-systolic elastance (Ees), the gold standard method for assessing LV contractility.Results: Endotoxin-induced shock and catecholamine infusion lead to significant variations in LV contractility. Overall, significant correlation (r = 0.51; p < 0.001) but low agreement between the two methods were observed. However, a far better correlation with a good agreement were observed when positive-pressure ventilation induced an arterial pulse pressure variation (PPV) ≤ 11% (r = 0.77; p < 0.001).Conclusion: While arterial dP/dt maxand Ees were significantly correlated during various hemodynamic conditions, arterial dP/dt maxwas more accurate for assessing LV contractility when adequate vascular filling, defined as PPV ≤ 11%, was achieved. © 2012 Morimont et al; licensee BioMed Central Ltd

    Pulmonary Impedance and Right Ventricular-Vascular Coupling in Endotoxin Shock

    Full text link
    OBJECTIVE: We tested the hypothesis that right heart failure during endotoxin shock may result from altered ventriculovascular coupling responsible for impeding power transfer to the pulmonary circulation. METHODS: The changes in vascular pulmonary input impedance and right ventricular contractility produced by low-dose endotoxin infusion were studied in 6 intact anesthetized dogs. RESULTS: Endotoxin insult resulted in pulmonary hypertension (from 22 +/- 2 to 33 +/- 3 mmHg) associated with significant decreases in stroke volume (from 26.9 +/- 4 to 20.2 +/- 3 ml) and right ventricular ejection fraction (from 41 +/- 3 to 32 +/- 2%). The first minimum of input impedance spectrum and zero phase were shifted towards higher frequencies. Input resistance and characteristic resistance were dramatically increased. The latter change contributed to a significant increase in the pulsatile component of total right ventricular power output from 13 to 21%, indicating a reduction in the hydraulic right ventricle power output delivered into the main pulmonary artery. Overall changes in input pulmonary impedance were indicative of increased afterload facing the right ventricle leading to depressed performance. In contrast, right ventricular systolic elastance was simultaneously increased from 0.56 to 0.93 mmHg/ml indicating an increase in right heart contractility. CONCLUSION: These data suggest that pulmonary hypertension in the setting of experimental endotoxin shock is accompanied by deleterious changes in the pulmonary impedance spectrum, which are responsible for a mismatch of increased contractile state of the right ventricle to the varying hydraulic load ultimately leading to ventricular-vascular uncoupling

    Cystatin C blood level as a risk factor for death after heart surgery.

    Full text link
    peer reviewe

    Aortic pseudo-aneurysm after coarctation repair

    Full text link
    peer reviewedAortic pseudo-aneurysm is a well-known late complication after surgical repair of aortic coarctation. We report two cases of pseudo-aneurysm of the aortic isthmus evidenced after previous surgical repair of congenital aortic coarctation. These clinical observations give us the opportunity to underline the importance of a specific lifelong medical follow-up for patients who have undergone such surgery
    corecore