218 research outputs found

    Laser-generated plasmas by graphene nanoplatelets embedded into polyethylene

    Get PDF
    AbstractGraphene micrometric particles have been embedded into polyethylene at different concentrations by using chemical–physical processes. The synthesized material was characterized in terms of mechanical and optical properties, and Raman spectroscopy. Obtained targets were irradiated by using a Nd:YAG laser at intensities of the order of 1010 W/cm2 to generate non-equilibrium plasma expanding in vacuum. The laser–matter interaction produces charge separation effects with consequent acceleration of protons and carbon ions. Plasma was characterized using time-of-flight measurements of the accelerated ions. Applications of the produced targets in order to generate carbon and proton ion beams from laser-generated plasma are presented and discussed

    Laser-generated nanoparticles to change physical properties of solids, liquids and gases

    Get PDF
    Synthesis of nanoparticles was possible employing a Nd: YAG pulsed laser at fundamental harmonic. The production of nanoparticles in water depends mainly on the laser parameters (pulse duration, energy, wavelength), the irradiation conditions (focal spot, repetition rate, irradiation time) and the medium where the ablation occurs (solid target, water, solution concentration). The nanoparticles can be introduced in solids, liquids or gases to change many physical characteristics. The optical properties of polymers and solutions, the wetting ability of liquids, the electron density of laser-generated plasma, represent some examples that can be controlled by the concentration of metallic nanoparticles (Au, Ag, Ti, Cu). Some bio-medical applications will be presented and discussed

    The arterial blood supply of the temporomandibular joint: an anatomical study and clinical implications.

    Get PDF
    Purpose: The aim of this study was to analyze three-dimensional images of the arterial supply to the temporomandibular joint. Materials and Methods: Ten patients (five men and five women, mean age 36 years) without signs or symptoms of temporomandibular disorders, who underwent contrast-enhanced computed tomographic (CT) scanning with intravenous contrast, were studied. The direct volume rendering technique of CT images was used, and a data set of images to visualize the vasculature of the human temporomandibular joint in three dimensions was created. After elaboration of the data through post-processing, the arterial supply of the temporomandibular joint was studied. Results: The analysis revealed the superficial temporal artery, the anterior tympanic artery, the deep temporal artery, the auricular posterior artery, the transverse facial artery, the middle meningeal artery, and the maxillary artery with their branches as the main arterial sources for the lateral and medial temporomandibular joint. Conclusion: The direct volume rendering technique was found to be successful in the assessment of the arterial supply to the temporomandibular joint. The superficial temporal artery and maxillary artery ran along the lateral and medial sides of the condylar neck, suggesting that these arteries are at increased risk during soft-tissue procedures such as an elective arthroplasty of the temporomandibular joint

    Production and characterization of micro-size pores for ion track etching applications

    Get PDF
    For many years the applications of ion track etch materials have increased considerably, like charged particles detection, molecular identification with nanopores, ion track filters, magnetic studies with nanowires and so on. Over the materials generally used as track detector, the Poly-Allyl-Diglycol Carbonate (PADC), offers many advantages, like its nearly 100 % detection efficiency for charged particle, a high resistance to harsh environment, the lowest detection threshold, a high abrasion resistance and a low production costs. All of these properties have made it particularly attractive material, even if due to its brittleness, obtaining a thin film (less than 500 μm) is still a challenge. In this work, PADC foils have been exposed to a-particles emitted by a thin radioactive source of 241Am and to C ions from the Tandetron 4130 MC accelerator. The latent tracks generated in the polymer have been developed using a standard etching procedure in 6.25 NaOH solution. The dependence of the ion tracks' geometry on the ion beam energy and fluence has been evaluated combining the information obtained through a semiautomatic computer script that selects the etched ion tracks according to their diameter and mean grey value and nanometric resolution images by atomic force microscopy

    Post-Marketing Surveillance of CAR-T-Cell Therapies: Analysis of the FDA Adverse Event Reporting System (FAERS) Database

    Get PDF
    Introduction As chimeric antigen receptor T-cell therapies are becoming increasingly available in the armamentarium of the hematologist, there is an emerging need to monitor post-marketing safety. Objective We aimed to better characterize their safety profile by focusing on cytokine release syndrome and identifying emerging signals. Methods We queried the US Food and Drug Administration Adverse Event Reporting System (October 2017-September 2020) to analyze suspected adverse drug reactions to tisagenlecleucel (tisa-cel) and axicabtagene ciloleucel (axi-cel). Disproportionality analyses (reporting odds ratio) were performed by comparing chimeric antigen receptor T-cell therapies with (a) all other drugs (reference group 1) and (b) other onco-hematological drugs with a similar indication, irrespective of age (reference group 2), or (c) restricted to adults (reference group 3). Notoriety was assessed through package inserts and risk management plans. Adverse drug reaction time to onset and cytokine release syndrome features were investigated. Results Overall, 3225 reports (1793 axi-cel; 1433 tisa-cel) were identified. The reported toxicities were mainly: cytokine release syndrome (52.2%), febrile disorders (27.7%), and neurotoxicity (27.2%). Cytokine release syndrome and neurotoxicity were often co-reported and 75% of the events occurred in the first 10 days. Disproportionalities confirmed known adverse drug reactions and showed unexpected associations: for example, axi-cel with cardiomyopathies (reporting odds ratio = 2.3; 95% confidence interval 1.2-4.4) and gastrointestinal perforations (2.9; 1.2-7.3), tisa-cel with hepatotoxicity (2.5; 1.1-5.7) and pupil disorders (15.3; 6-39.1). Conclusions Our study confirms the well-known adverse drug reactions and detects potentially emerging safety issues specific for each chimeric antigen receptor T-cell therapy, also providing insights into a stronger role for tisa-cel in inducing some immunodeficiency-related events (e.g., hypogammaglobulinemia, infections) and coagulopathies, and for axi-cel in neurotoxicity

    Protons accelerated in the target normal sheath acceleration regime by a femtosecond laser

    Get PDF
    Advanced targets based on thin films of graphene oxide covered by metallic layers have been irradiated at high laser intensity (∼1019 W/cm2) with 40 fs laser pulses to investigate the forward ion acceleration in the target normal sheath acceleration regime. A time-of-flight technique was employed with silicon-carbide detectors and ion collectors as fast on-line plasma diagnostics. At the optimized conditions of the laser focus position with respect to the target surface was measured the maximum proton energy using Au metallic films. A maximum proton energy of 2.85 MeV was measured using the Au metallization of 200 nm. The presence of graphene oxide facilitates the electron crossing of the foil minimizing the electron scattering and increasing the electric field driving the ion acceleration. The effect of plasma electron density control using the graphene oxide is presented and discussed
    • …
    corecore