117 research outputs found
Phase I–II trial design for biologic agents using conditional auto‐regressive models for toxicity and efficacy
Peer Reviewedhttps://deepblue.lib.umich.edu/bitstream/2027.42/147824/1/rssc12314_am.pdfhttps://deepblue.lib.umich.edu/bitstream/2027.42/147824/2/rssc12314.pd
Survey of Barbell Trajectory and Kinematics of the Snatch Lift from the 2015 World and 2017 Pan-American Weightlifting Championships
Analysis of elite performances is important to elucidate the characteristics of effective weightlifting technique contributing to the highest level of achievement. The general technique of the weightlifting movements is well established. However, it is also apparent that weightlifting technique can differ based on athlete characteristics. Thus, existing technical models may not accurately reflect current technique of top performers or be applied generically to athletes of different skill, size, sex, or ability. Therefore, the purpose of this descriptive study was to update the scientific knowledge of snatch technique of top international weightlifters. This study used video analysis to determine barbell trajectory and kinematics of 319 successful snatch attempts from two major international competitions. Relative frequencies of barbell trajectory types differed based on competition, sex, category, and ranking. No statistical differences were observed among the top-three performers for either sex for most kinematic variables, and there were no overall discernible patterns of effect size differences for individual or clusters of kinematic variables. The results of this study indicate that weightlifting success can be achieved with a variety of technique profiles
Performance Comparisons of Youth Weightlifters as a Function of Age Group and Sex
This study was designed to provide an overview of weightlifting performance as a function of age group and sex and evaluate the potential of countermovement jump height (CMJH) as a tool to gauge performance potential. Data from 130 youth athletes (female, n = 65 & male, n = 65) were used to examine progression of performance (Total and Sinclair total) and the relationship between CMJH and Sinclair total while considering interactions between CMJH and age and/or sex. ANOVAs with post hoc analyses revealed that both totals had a statistical first-order polynomial interaction effect between age group and sex and the difference between age groups of 12–13 and 14–15 years old was statistically greater for male than female. A linear model, developed to examine the relationship, revealed that CMJH and CMJH x sex x age rejected the null hypothesis. Our primary findings are that male youth weightlifters have a higher rate of performance progression, possibly owing to puberty, and CMJH may be a better gauging tool for older male youth weightlifters
Comparison of the Relationship between Lying and Standing Ultrasonography Measures of Muscle Morphology with Isometric and Dynamic Force Production Capabilities
The purpose of the current study was (1) to examine the differences between standing and lying measures of vastus lateralis (VL), muscle thickness (MT), pennation angle (PA), and cross-sectional area (CSA) using ultrasonography; and (2) to explore the relationships between lying and standing measures with isometric and dynamic assessments of force production—specifically peak force, rate of force development (RFD), impulse, and one-repetition maximum back squat. Fourteen resistance-trained subjects (age = 26.8 ± 4.0 years, height = 181.4 ± 6.0 cm, body mass = 89.8 ± 10.7 kg, back squat to body mass ratio = 1.84 ± 0.34) agreed to participate. Lying and standing ultrasonography images of the right VL were collected following 48 hours of rest. Isometric squat assessments followed ultrasonography, and were performed on force platforms with data used to determine isometric peak force (IPF), as well as RFD and impulse at various time points. Forty-eight hours later, one-repetition maximum back squats were performed by each subject. Paired-samples t-tests revealed statistically significant differences between standing and lying measurements of MT (p \u3c 0.001), PA (p \u3c 0.001), and CSA (p ≤ 0.05), with standing values larger in all cases. Further, standing measures were correlated more strongly and abundantly to isometric and dynamic performance. These results suggest that if practitioners intend to gain insight into strength-power potential based on ultrasonography measurements, performing the measurement collection with the athlete in a standing posture may be preferred
Comparison of the Relationship between Lying and Standing Ultrasonography Measures of Muscle Morphology with Isometric and Dynamic Force Production Capabilities
The purpose of the current study was (1) to examine the differences between standing and lying measures of vastus lateralis (VL), muscle thickness (MT), pennation angle (PA), and cross-sectional area (CSA) using ultrasonography; and (2) to explore the relationships between lying and standing measures with isometric and dynamic assessments of force production—specifically peak force, rate of force development (RFD), impulse, and one-repetition maximum back squat. Fourteen resistance-trained subjects (age = 26.8 ± 4.0 years, height = 181.4 ± 6.0 cm, body mass = 89.8 ± 10.7 kg, back squat to body mass ratio = 1.84 ± 0.34) agreed to participate. Lying and standing ultrasonography images of the right VL were collected following 48 hours of rest. Isometric squat assessments followed ultrasonography, and were performed on force platforms with data used to determine isometric peak force (IPF), as well as RFD and impulse at various time points. Forty-eight hours later, one-repetition maximum back squats were performed by each subject. Paired-samples t-tests revealed statistically significant differences between standing and lying measurements of MT (p \u3c 0.001), PA (p \u3c 0.001), and CSA (p ≤ 0.05), with standing values larger in all cases. Further, standing measures were correlated more strongly and abundantly to isometric and dynamic performance. These results suggest that if practitioners intend to gain insight into strength-power potential based on ultrasonography measurements, performing the measurement collection with the athlete in a standing posture may be preferred
Repetition-to-Repetition Differences Using Cluster and Accentuated Eccentric Loading in the Back Squat
The current investigation was an examination of the repetition-to-repetition magnitudes and changes in kinetic and kinematic characteristics of the back squat using accentuated eccentric loading (AEL) and cluster sets. Trained male subjects (age = 26.1 ± 4.1 years, height = 183.5 ± 4.3 cm, body mass = 92.5 ± 10.5 kg, back squat to body mass ratio = 1.8 ± 0.3) completed four load condition sessions, each consisting of three sets of five repetitions of either traditionally loaded straight sets (TL), traditionally loaded cluster sets (TLC), AEL cluster sets (AEC), and AEL straight sets where only the initial repetition had eccentric overload (AEL1). Eccentric overload was applied using weight releasers, creating a total eccentric load equivalent to 105% of concentric one repetition maximum (1RM). Concentric load was 80% 1RM for all load conditions. Using straight sets (TL and AEL1) tended to decrease peak power (PP) (d = −1.90 to −0.76), concentric rate of force development (RFDCON) (d = −1.59 to −0.27), and average velocity (MV) (d = −3.91 to −1.29), with moderate decreases in MV using cluster sets (d = −0.81 to −0.62). Greater magnitude eccentric rate of force development (RFDECC) was observed using AEC at repetition three (R3) and five (R5) compared to all load conditions (d = 0.21⁻0.65). Large within-condition changes in RFDECC from repetition one to repetition three (∆REP1⁻3) were present using AEL1 (d = 1.51), demonstrating that RFDECC remained elevated for at least three repetitions despite overload only present on the initial repetition. Overall, cluster sets appear to permit higher magnitude and improved maintenance of concentric outputs throughout a set. Eccentric overload with the loading protocol used in the current study does not appear to potentiate concentric output regardless of set configuration but may cause greater RFDECC compared to traditional loading
Sheffield One‐Stop Service: A potential model to improve the screening uptake of diabetic peripheral neuropathy and other microvascular complications of diabetes
The world is experiencing an enormous rise in the prevalence of diabetes, which is associated with massive healthcare costs that threaten to overwhelm many healthcare systems. Most of the diabetes expenditure is attributed to the management of chronic diabetes complications, including diabetic peripheral neuropathy (DPN)/diabetic foot complications, chronic kidney disease, sight-threatening retinopathy and cardiovascular diseases. Of these complications, the most overlooked is DPN. Most consultations around the world do not even involve taking off shoes and socks to carry out a foot examination, and even when carried out, the peripheral neurological examination using the 10-g monofilament diagnoses DPN when it is already at an advanced stage. Thus, all too often diabetes complications are diagnosed late, resulting in devastating outcomes, particularly in low- to middle-income countries. There is, therefore, an urgent need to instigate new strategies to improve microvascular screening uptake using a holistic protocol for annual diabetes health checks outside the busy diabetes clinic. One such approach, the Sheffield One-Stop Microvascular Screening Service, which involves modern point of care devices to diagnose DPN, has been shown to be feasible and effective, resulting in high uptake and early management of diabetes complications. This article outlines the advantages of this One-Stop Microvascular Screening Service and a plan to trial an adapted version of this service to a resource-limited country, the Philippines. If successful, this model has the potential for implementation in other countries around the world
Repetition-to-Repetition Differences Using Cluster and Accentuated Eccentric Loading in the Back Squat
The current investigation was an examination of the repetition-to-repetition magnitudes and changes in kinetic and kinematic characteristics of the back squat using accentuated eccentric loading (AEL) and cluster sets. Trained male subjects (age = 26.1 ± 4.1 years, height = 183.5 ± 4.3 cm, body mass = 92.5 ± 10.5 kg, back squat to body mass ratio = 1.8 ± 0.3) completed four load condition sessions, each consisting of three sets of five repetitions of either traditionally loaded straight sets (TL), traditionally loaded cluster sets (TLC), AEL cluster sets (AEC), and AEL straight sets where only the initial repetition had eccentric overload (AEL1). Eccentric overload was applied using weight releasers, creating a total eccentric load equivalent to 105% of concentric one repetition maximum (1RM). Concentric load was 80% 1RM for all load conditions. Using straight sets (TL and AEL1) tended to decrease peak power (PP) (d = −1.90 to −0.76), concentric rate of force development (RFDCON) (d = −1.59 to −0.27), and average velocity (MV) (d = −3.91 to −1.29), with moderate decreases in MV using cluster sets (d= −0.81 to −0.62). Greater magnitude eccentric rate of force development (RFDECC) was observed using AEC at repetition three (R3) and five (R5) compared to all load conditions (d = 0.21–0.65). Large within-condition changes in RFDECC from repetition one to repetition three (∆REP1–3) were present using AEL1 (d = 1.51), demonstrating that RFDECC remained elevated for at least three repetitions despite overload only present on the initial repetition. Overall, cluster sets appear to permit higher magnitude and improved maintenance of concentric outputs throughout a set. Eccentric overload with the loading protocol used in the current study does not appear to potentiate concentric output regardless of set configuration but may cause greater RFDECCcompared to traditional loadin
- …