469 research outputs found
Psychoacoustic measurement of phase and level for cross-talk cancellation using bilateral bone transducers: Comparison of methods
Two bone-conduction hearing aids (BCHAs) could deliver improved stereo separation using cross-talk cancellation. Sound vibrations from each BCHA would be cancelled at the contralateral cochlea by an out-of-phase signal of the same level from the ipsilateral BCHA. A method to measure the level and phase required for these cancellation signals was developed and cross-validated with an established technique that combines air- and bone-conducted sound. Three participants with normal hearing wore bone transducers (BTs) on each mastoid and insert earphones. Both BTs produced a pure tone and the level and phase were adjusted in the right BT in order to cancel all perceived sound at that ear. To cross-validate, one BT was stimulated with a pure tone and participants cancelled the resultant signal at both cochleae via adjustment of the phase and level of signals from the earphones. Participants achieved cancellation using both methods between 1.5 and 8 kHz. Levels measured with each method differed by <1 dB between 3 and 5 kHz. The phase results also corresponded well for the cancelled ear (11° mean difference) but poorly for the contralateral ear (38.4° mean difference). The first method is transferable to patients with middle-ear dysfunction, but covers a limited frequency range
Measurements of inter-cochlear level and phase differences of bone-conducted sound
Bone-anchored hearing aids are a widely used method of treating conductive hearing loss, but the benefit of bilateral implantation is limited due to interaural cross-talk. The present study measured the phase and level of pure tones reaching each cochlea from a single, mastoid placed bone transducer on normal hearing participants. In principle, the technique could be used to implement a cross-talk cancellation system in those with bilateral bone conductors. The phase and level of probe tones over two insert earphones was adjusted until they canceled sound from a bone transducer (i.e., resulting in perceived silence). Testing was performed in 50-Hz steps between 0.25 and 8 kHz. Probe phase and level results were used to calculate inter-cochlear level and phase differences. The inter-cochlear phase differences of the bone-conducted sound were similar for all three participants showing a relatively linear increase between 4 and 8 kHz. The attenuation characteristics were highly variable over the frequency range as well as between participants. This variability was thought to be related to differences in skull dynamics across the ears. Repeated measurements of cancellation phase and level of the same frequency produced good consistency across sessions from the same participant
Elite Scientists and the Global Brain Drain
There are signs â one is world university league tables â that people increasingly think globally when choosing the university in which they wish to work and study. This paper is an exploration of data on the international brain drain. We study highly-cited physicists, highly-cited bio-scientists, and assistant professors of economics. First, we demonstrate that talented researchers are being systematically funnelled into a small number of countries. Among young economists in the top American universities, for example, 75% did their undergraduate degree outside the United States. Second, the extent of the elite brain drain is considerable. Among the worldâs top physicists, nearly half no longer work in the country in which they were born. Third, the USA and Switzerland are per capita the largest net-importers of elite scientists. Fourth, we estimate the migration âfunnelling coefficientâ at approximately 0.2 (meaning that 20% of top researchers tend to leave their country at each professional stage). Fifth, and against our prior expectations, the productivity of top scientists, as measured by the Hirsch h-index, is similar between the elite movers and stayers. Thus it is apparently not true that it is disproportionately the very best people who emigrate. Sixth, there is extreme clustering of ISI Highly Cited Researchers into particular fields in different universities. Seventh, we debate the questions: are the brain drain and this kind of funnelling good or bad for the world, and how should universities and governments respond?
Elite scientists and the global brain drain
There are signs â one is world university league tables â that people increasingly think globally when choosing the university in which they wish to work and study. This paper is an exploration of data on the international brain drain. We study highly-cited physicists, highly-cited bio-scientists, and assistant professors of economics. First, we demonstrate that talented researchers are being systematically funnelled into a small number of countries. Among young economists in the top American universities, for example, 75% did their undergraduate degree outside the United States. Second, the extent of the elite brain drain is considerable. Among the worldâs top physicists, nearly half no longer work in the country in which they were born. Third, the USA and Switzerland are per capita the largest net-importers of elite scientists. Fourth, we estimate the migration âfunnelling coefficientâ at approximately 0.2 (meaning that 20% of top researchers tend to leave their country at each professional stage). Fifth, and against our prior expectations, the productivity of top scientists, as measured by the Hirsch h-index, is similar between the elite movers and stayers. Thus it is apparently not true that it is disproportionately the very best people who emigrate. Sixth, there is extreme clustering of ISI Highly Cited Researchers into particular fields in different universities. Seventh, we debate the questions: are the brain drain and this kind of funnelling good or bad for the world, and how should universities and governments respond?
To be presented at the World Universities Conference in Shanghai, October 2007
Turn an Ear to Hear: How Hearing-Impaired Listeners Can Exploit Head Orientation to Enhance Their Speech Intelligibility in Noisy Social Settings
Turning an ear toward the talker can enhance spatial release from masking. Here, with their head free, listeners attended to speech at a gradually diminishing signal-to-noise ratio and with the noise source azimuthally separated from the speech source by 180° or 90°. Young normal-hearing adult listeners spontaneously turned an ear toward the speech source in 64% of audio-only trials, but a visible talkerâs face or cochlear implant (CI) use significantly reduced this head-turn behavior. All listener groups made more head movements once instructed to explore the potential benefit of head turns and followed the speech to lower signal-to-noise ratios. Unilateral CI users improved the most. In a virtual restaurant simulation with nine interfering noises or voices, hearing-impaired listeners and simulated bilateral CI users typically obtained a 1 to 3 dB head-orientation benefit from a 30° head turn away from the talker. In diffuse interference environments, the advice to U.K. CI users from many CI professionals and the communication guidance available on the Internet most often advise the CI user to face the talker head on. However, CI users would benefit from guidelines that recommend they look sidelong at the talker with their better hearing or implanted ear oriented toward the talker
Evaluation of a method for enhancing interaural level differences at low frequencies.
A method (called binaural enhancement) for enhancing interaural level differences at low frequencies, based on estimates of interaural time differences, was developed and evaluated. Five conditions were compared, all using simulated hearing-aid processing: (1) Linear amplification with frequency-response shaping; (2) binaural enhancement combined with linear amplification and frequency-response shaping; (3) slow-acting four-channel amplitude compression with independent compression at the two ears (AGC4CH); (4) binaural enhancement combined with four-channel compression (BE-AGC4CH); and (5) four-channel compression but with the compression gains synchronized across ears. Ten hearing-impaired listeners were tested, and gains and compression ratios for each listener were set to match targets prescribed by the CAM2 fitting method. Stimuli were presented via headphones, using virtualization methods to simulate listening in a moderately reverberant room. The intelligibility of speech at ±60° azimuth in the presence of competing speech on the opposite side of the head at ±60° azimuth was not affected by the binaural enhancement processing. Sound localization was significantly better for condition BE-AGC4CH than for condition AGC4CH for a sentence, but not for broadband noise, lowpass noise, or lowpass amplitude-modulated noise. The results suggest that the binaural enhancement processing can improve localization for sounds with distinct envelope fluctuations
Assessment of blood-brain barrier disruption using dynamic contrast-enhanced MRI. A systematic review
AbstractThere is increasing recognition of the importance of bloodâbrain barrier (BBB) disruption in aging, dementia, stroke and multiple sclerosis in addition to more commonly-studied pathologies such as tumors. Dynamic contrast-enhanced MRI (DCE-MRI) is a method for studying BBB disruption in vivo. We review pathologies studied, scanning protocols and data analysis procedures to determine the range of available methods and their suitability to different pathologies. We systematically review the existing literature up to February 2014, seeking studies that assessed BBB integrity using T1-weighted DCE-MRI techniques in animals and humans in normal or abnormal brain tissues. The literature search provided 70 studies that were eligible for inclusion, involving 417 animals and 1564 human subjects in total. The pathologies most studied are intracranial neoplasms and acute ischemic strokes. There are large variations in the type of DCE-MRI sequence, the imaging protocols and the contrast agents used. Moreover, studies use a variety of different methods for data analysis, mainly based on model-free measurements and on the Patlak and Tofts models. Consequently, estimated KTrans values varied widely. In conclusion, DCE-MRI is shown to provide valuable information in a large variety of applications, ranging from common applications, such as grading of primary brain tumors, to more recent applications, such as assessment of subtle BBB dysfunction in Alzheimer's disease. Further research is required in order to establish consensus-based recommendations for data acquisition and analysis and, hence, improve inter-study comparability and promote wider use of DCE-MRI
Simulating the influences of groundwater on regional geomorphology using a distributed, dynamic, landscape evolution modelling platform
A dynamic landscape evolution modelling platform (CLiDE) is presented that allows a variety of Earth system interactions to be explored under differing environmental forcing factors. Representation of distributed surface and subsurface hydrology within CLiDE is suited to simulation at sub-annual to centennial time-scales. In this study the hydrological components of CLiDE are evaluated against analytical solutions and recorded datasets. The impact of differing groundwater regimes on sediment discharge is examined for a simple, idealised catchment, Sediment discharge is found to be a function of the evolving catchment morphology. Application of CLiDE to the upper Eden Valley catchment, UK, suggests the addition of baseflow-return from groundwater into the fluvial system modifies the total catchment sediment discharge and the spatio-temporal distribution of sediment fluxes during storm events. The occurrence of a storm following a period of appreciable antecedent rainfall is found to increase simulated sediment fluxes
- âŠ