31 research outputs found

    Caracterización mediante resonancia magnética cardiaca de un modelo porcino de infarto agudo de miocardio a tórax cerrado = Characterization by cardiac magnetic resonance of a closed-chest porcine model of acute myocardial infarction

    Get PDF
    212Este estudio pretendía demostrar que nuestro modelo experimental animal de infarto agudo de miocardio, obtenido mediante un procedimiento intervencionista de isquemia-reperfusión (oclusión con balón de angioplastia en la arteria coronaria descendente anterior) es factible y reproducible, y, que la resonancia magnética cardíaca (RMC) permitía una adecuada caracterización de los parámetros anatómicos y funcionales del ventrículo izquierdo (VI) en la fase aguda y crónica del infarto. Se utilizaron animales hembra de entre 25 y 30 kg de peso. El modelo porcino percutáneo de infarto-reperfusión propuesto es factible y presenta baja mortalidad. El tamaño del infarto, así como la disminución de la FEVI, obtenidos son reproducibles y dependen del segmento ocluído en la arteria coronaria descendente anterior. El proceso de remodelado ventricular se activa con un aumento progresivo del volumen y de la masa ventriculares. La magnitud de estos cambios está en relación con el tamaño del infarto obtenido. No se producen cambios significativos en los volúmenes ni masa ventriculares durante el crecimiento normal de éstos animales. La administración de BrdU en animales sanos y del modelo experimental propuesto no afecta a ninguno de los parámetros anatómicos ni funcionales cardíacos estudiado

    Development and Evaluation of a Disease Large Animal Model for Preclinical Assessment of Renal Denervation Therapies

    Get PDF
    [EN] New-generation catheters-based renal denervation (RDN) is under investigation for the treatment of uncontrolled hypertension (HTN). We assessed the feasibility of a large animal model of HTN to accommodate the human RDN devices. Ten minipigs were instrumented to measure blood pressure (BP) in an awake-state. HTN was induced with subcutaneous 11-deoxycorticosterone (DOCA, 100 mg/kg) implants. Five months after, the surviving animals underwent RDN with the Symplicity® system. Norepinephrine (NE) renal gradients were determined before and 1 month after RDN. Renal arteries were processed for histological (hematoxylin-eosin, Movat pentachrome) and immunohistochemical (S100, tyrosine-hydroxylase) analyses. BP significantly rose after DOCA implants. Six animals died prematurely, mainly from infectious causes. The surviving animals showed stable BP levels after 5 months. One month after RDN, nerve damage was showed in three animals, with impedance drop >10%, NE gradient drop and reduction in BP. The fourth animal showed no nerve damage, impedance drop <10%, NE gradient increase and no change in BP. In conclusion, the minipig model of DOCA-induced HTN is feasible, showing durable effects. High mortality should be addressed in next iterations of this model. RDN may partially offset the DOCA-induced HTN. Impedance drop and NE renal gradient could be markers of RDN success.SIThis research was funded by Consejería de Salud, Junta de Castilla and Leon, Spain, the Grant GRS 1001/A/2014.We want to thank Medtronic Iberia for the donation of the Symplicity catheters used in this experiment

    Instantaneous Wave-Free Ratio for the Assessment of Intermediate Left Main Coronary Artery Stenosis: Correlations With Fractional Flow Reserve/Intravascular Ultrasound and Prognostic Implications: The iLITRO-EPIC07 Study

    Full text link
    Background: There is little information available on agreement between fractional flow reserve (FFR) and instantaneous wave-free ratio (iFR) in left main coronary artery (LMCA) intermediate stenosis. Besides, several meta-analyses support the use of FFR to guide LMCA revascularization, but limited information is available on iFR in this setting. Our aims were to establish the concordance between FFR and iFR in intermediate LMCA lesions, to evaluate with intravascular ultrasound (IVUS) in cases of FFR/iFR discordance, and to prospectively validate the safety of deferring revascularization based on a hybrid decision-making strategy combining iFR and IVUS. Methods: Prospective, observational, multicenter registry with 300 consecutive patients with intermediate LMCA stenosis who underwent FFR and iFR and, in case of discordance, IVUS and minimal lumen area measurements. Primary clinical end point was a composite of cardiovascular death, LMCA lesion-related nonfatal myocardial infarction, or unplanned LMCA revascularization. Results: FFR and iFR had an agreement of 80% (both positive in 67 and both negative in 167 patients); in case of disagreement (31 FFR+/iFR- and 29 FFR-/iFR+) minimal lumen area was & GE;6 mm(2) in 8.7% of patients with FFR+ and 14.6% with iFR+. Among the 300 patients, 105 (35%) underwent revascularization and 181 (60%) were deferred according to iFR and IVUS. At a median follow-up of 20 months, major adverse cardiac events incidence was 8.3% in the defer group and 13.3% in the revascularization group (hazard ratio, 0.71 [95% CI 0.30-1.72]; P=0.45). Conclusions: In patients with intermediate LMCA stenosis, a physiology-guided treatment decision is feasible either with FFR or iFR with moderate concordance between both indices. In case of disagreement, the use of IVUS may be useful to indicate revascularization. Deferral of revascularization based on iFR appears to be safe in terms of major adverse cardiac events

    Third CoreValve™ insertion for treatment of a severe paravalvular leak after a failed valve-in-valve procedure

    No full text
    An 83-year-old high-risk gentleman diagnosed with severe symptomatic aortic stenosis was scheduled for TAVR. A 31 mm CoreValve was implanted but severe paravalvular leak was noted. A valve-in-valve procedure was performed. However, the valve frame was partially dislodged into de ascending aorta. We report our strategy to solve this severe leak after a failed valve-in-valve procedure

    Third CoreValve™ insertion for treatment of a severe paravalvular leak after a failed valve-in-valve procedure

    Get PDF
    An 83-year-old high-risk gentleman diagnosed with severe symptomatic aortic stenosis was scheduled for TAVR. A 31 mm CoreValve was implanted but severe paravalvular leak was noted. A valve-in-valve procedure was performed. However, the valve frame was partially dislodged into de ascending aorta. We report our strategy to solve this severe leak after a failed valve-in-valve procedure

    Incidence and prognostic implications of late bleeding events after percutaneous mitral valve repair

    No full text
    Objectives: MitraClip is an established therapy for patients with mitral regurgitation (MR) that are considered of high-risk or inoperable. However, late bleeding events (BE) after hospital discharge and their impact on prognosis in this cohort of patients have been poorly investigated. Our purpose is to address the incidence, related factors and clinical implications of BE after hospital discharge in patients treated with MitraClip. Methods: Prospective registry of all consecutive patients (n = 80) who underwent MitraClip implantation in our Institution between June 2014 and December 2017. BE were defined according to MVARC definitions. A combined clinical end-point including admission for heart failure (HF) and all-cause mortality was established to analyze prognostic implications of BE. Results: During a median follow up of 523.5 days, 41 BE were reported in 21 patients. Atrial fibrillation (AF, HR 4.54, CI95% 1.20–17.10) and combined antithrombotic therapy at discharge (HR 3.52, CI95% 1.03–11.34) were independently associated with BE. In the study period, 15 (18.8%) patients died, 20 (25%) were admitted for HF and 29 (36.3%) presented the combined end-point. After multivariable adjustment BE remained independently associated with an adverse outcome (HR 3.80, CI 95% 1.66–8.72). In the subgroup of patients with AF, HAS-BLED score was higher among subjects with BE (3.1 ± 1.3 vs 2.1 ± 0.9, p = 0.003). HAS-BLED score had a significant discrimination power for the occurrence BE (AUC: 0.677 [0.507–0.848]) in this subgroup. Conclusions: BE are common after MitraClip and are associated with an impaired outcome. Strategies to reduce bleeding events are paramount in this cohort of patients. Keywords: MitraClip, Atrial fibrillation, Bleeding event
    corecore