9 research outputs found
the gateway to the future of nephrology
Funding Information: The Young Nephrologists’ Platform is an official body of the ERA.publishersversionpublishe
Mycophenolate Mofetil Therapy in Children With Idiopathic Nephrotic Syndrome: Does Therapeutic Drug Monitoring Make a Difference?
Background: Idiopathic nephrotic syndrome (INS) necessitates administration of corticosteroids or corticoid-sparing agents in 60% of the cases for prolonged periods resulting in serious adverse effects. Methods: To avoid these complications, we investigated the efficacy and safety of mycophenolate mofetil (MMF) in our retrospective single-center study with 15 patients presenting with complicated courses of INS and aspired to estimate a cutoff level for mycophenolic acid-area under the curve (MPA-AUC) values, which can predict relapses with high sensitivity. Results: Seven of 15 patients stayed in remission while receiving MMF. Average frequency of relapses was 1.39 (0.28-2.5) per year. In case of relapses, patients had lower predose and estimated AUC(0-12) levels of MPA (P = 0.02 and 0.001, respectively). Based on the results of receiver operating characteristic analysis, we consider an estimated MPA-AUC(0-12) lower than 44.6 mg.h.L-1 as a risk factor for future relapses (91% sensitivity, 57% specificity, P = 0.06) because the prevalence of relapse is significantly lower (0.07 versus 0.5, P = 0.02), if the estimated MPA-AUC(0-12) is >44.6 mg.h.L-1. During MMF administration, we did not detect any adverse event requiring discontinuation of treatment. Conclusions: In conclusion, we demonstrate MMF as an alternative treatment for children with complicated INS to maintain remission without serious side effects. Furthermore, we propose a higher therapeutic target range of MPA-AUC(0-12) (>45 mg.h.L-1) than used in transplanted children underlining the crucial role of therapeutic drug monitoring
Recommended from our members
History of posttraumatic stress disorder and outcomes after kidney transplantation.
A history of posttraumatic stress disorder (PTSD), if uncontrolled, represents a contraindication for kidney transplantation. However, no previous large study has assessed the association between pretransplant history of PTSD and posttransplantation outcomes. We examined 4479 US veterans who had undergone transplantation. The diagnosis of history of PTSD was based on a validated algorithm. Measured covariates were used to create a matched cohort (n = 560). Associations between pretransplant PTSD and death with functioning graft, all-cause death, and graft loss were examined in survival models. Posttransplant medication nonadherence was assessed using proportion of days covered (PDC). From among 4479 veterans, 282 (6.3%) had a history of PTSD. The mean age ± standard deviation (SD) of the cohort at baseline was 61 ± 11 years, 91% were male, and 66% and 28% of patients were white and African American, respectively. Compared to patients without a history of PTSD, patients with a history of PTSD had a similar risk of death with a functioning graft (subhazard ratio [SHR] 0.97, 95% confidence interval [CI] 0.61-1.54), all-cause death (1.05, 0.69-1.58), and graft loss (1.09, 0.53-2.26). Moreover, there was no difference in immunosuppressive drug PDC in patients with and without a history of PTSD (PDC: 98 ± 4% vs 99 ± 3%, P = .733 for tacrolimus; PDC: 99 ± 4% vs 98 ± 7%, P = .369 for mycophenolic acid). A history of PTSD in US veterans with end-stage renal disease should not on its own preclude a veteran from being considered for transplantation
Recommended from our members
History of posttraumatic stress disorder and outcomes after kidney transplantation.
A history of posttraumatic stress disorder (PTSD), if uncontrolled, represents a contraindication for kidney transplantation. However, no previous large study has assessed the association between pretransplant history of PTSD and posttransplantation outcomes. We examined 4479 US veterans who had undergone transplantation. The diagnosis of history of PTSD was based on a validated algorithm. Measured covariates were used to create a matched cohort (n = 560). Associations between pretransplant PTSD and death with functioning graft, all-cause death, and graft loss were examined in survival models. Posttransplant medication nonadherence was assessed using proportion of days covered (PDC). From among 4479 veterans, 282 (6.3%) had a history of PTSD. The mean age ± standard deviation (SD) of the cohort at baseline was 61 ± 11 years, 91% were male, and 66% and 28% of patients were white and African American, respectively. Compared to patients without a history of PTSD, patients with a history of PTSD had a similar risk of death with a functioning graft (subhazard ratio [SHR] 0.97, 95% confidence interval [CI] 0.61-1.54), all-cause death (1.05, 0.69-1.58), and graft loss (1.09, 0.53-2.26). Moreover, there was no difference in immunosuppressive drug PDC in patients with and without a history of PTSD (PDC: 98 ± 4% vs 99 ± 3%, P = .733 for tacrolimus; PDC: 99 ± 4% vs 98 ± 7%, P = .369 for mycophenolic acid). A history of PTSD in US veterans with end-stage renal disease should not on its own preclude a veteran from being considered for transplantation
Oxygenated End-Hypothermic Machine Perfusion in Expanded Criteria Donor Kidney Transplant: A Randomized Clinical Trial.
Continuous hypothermic machine perfusion during organ preservation has a beneficial effect on graft function and survival in kidney transplant when compared with static cold storage (SCS). To compare the effect of short-term oxygenated hypothermic machine perfusion preservation (end-HMPo2) after SCS vs SCS alone on 1-year graft survival in expanded criteria donor kidneys from donors who are brain dead. In a prospective, randomized, multicenter trial, kidneys from expanded criteria donors were randomized to either SCS alone or SCS followed by end-HMPo2 prior to implantation with a minimum machine perfusion time of 120 minutes. Kidneys were randomized between January 2015 and May 2018, and analysis began May 2019. Analysis was intention to treat. On randomization and before implantation, deceased donor kidneys were either kept on SCS or placed on HMPo2. Primary end point was 1-year graft survival, with delayed graft function, primary nonfunction, acute rejection, estimated glomerular filtration rate, and patient survival as secondary end points. Centers in 5 European countries randomized 305 kidneys (median [range] donor age, 64 [50-84] years), of which 262 kidneys (127 [48.5%] in the end-HMPo2 group vs 135 [51.5%] in the SCS group) were successfully transplanted. Median (range) cold ischemia time was 13.2 (5.1-28.7) hours in the end-HMPo2 group and 12.9 (4-29.2) hours in the SCS group; median (range) duration in the end-HMPo2 group was 4.7 (0.8-17.1) hours. One-year graft survival was 92.1% (n = 117) in the end-HMPo2 group vs 93.3% (n = 126) in the SCS group (95% CI, -7.5 to 5.1; P = .71). The secondary end point analysis showed no significant between-group differences for delayed graft function, primary nonfunction, estimated glomerular filtration rate, and acute rejection. Reconditioning of expanded criteria donor kidneys from donors who are brain dead using end-HMPo2 after SCS does not improve graft survival or function compared with SCS alone. This study is underpowered owing to the high overall graft survival rate, limiting interpretation. isrctn.org Identifier: ISRCTN63852508
Measurement of pulse wave velocity in children and young adults: a comparative study using three different devices
To estimate the value of pulse wave velocity (PWV) in pediatric
cardiovascular disease, prospective studies are needed. Various
instruments based on different measurement principles are
proposed for use in children, hence the need to test the
comparability of these devices in this younger population. The
objective of this study was to compare PWV measured by
oscillometry (Vicorder (VIC)) with the gold standard of
applanation tonometry (PulsePen (PP), Sphygmocor (SC)). PWV was
measured in 98 children and young adults (age: 16.7(6.3-26.6)
years (median(range)) with the above three devices at the same
visit under standardized conditions. Mean PWV measured by VIC
was significantly lower than that measured by SC and PP. There
was no difference following path length correction of the VIC
measurement (using the distance between the jugular notch and
the center of the femoral cuff), (PP: 6.12(1.00), SC:
5.94(0.91), VIC: 6.14(0.75) m s(-1)). Velocities measured by the
three devices showed highly significant correlations. Bland-
Altman analysis revealed excellent concordance between all three
devices, however, there was a small but significant proportional
error in the VIC measurements showing a trend toward lower PWV
measured by VIC at higher PWV values. Our study provides data on
the three most frequently used instruments in pediatrics.
Following path length correction of the VIC, all three devices
provided comparable results. Thus, our work allows extrapolating
data between previously established normal PWV values for
children and forthcoming studies using these instruments to
assess children at long-term risk of cardiovascular disease. The
small proportional error of VIC needs additional technical
development to improve the accuracy of the
measurements.Hypertension Research advance online publication,
28 July 2011; doi:10.1038/hr.2011.103
Global distributions of age- and sex-related arterial stiffness : systematic review and meta-analysis of 167 studies with 509,743 participants
Background
Arterial stiffening is central to the vascular ageing process and a powerful predictor and cause of diverse vascular pathologies and mortality. We investigated age and sex trajectories, regional differences, and global reference values of arterial stiffness as assessed by pulse wave velocity (PWV).
Methods
Measurements of brachial-ankle or carotid-femoral PWV (baPWV or cfPWV) in generally healthy participants published in three electronic databases between database inception and August 24th, 2020 were included, either as individual participant-level or summary data received from collaborators (n = 248,196) or by extraction from published reports (n = 274,629). Quality was appraised using the Joanna Briggs Instrument. Variation in PWV was estimated using mixed-effects meta-regression and Generalized Additive Models for Location, Scale, and Shape.
Findings
The search yielded 8920 studies, and 167 studies with 509,743 participants from 34 countries were included. PWV depended on age, sex, and country. Global age-standardised means were 12.5 m/s (95% confidence interval: 12.1–12.8 m/s) for baPWV and 7.45 m/s (95% CI: 7.11–7.79 m/s) for cfPWV. Males had higher global levels than females of 0.77 m/s for baPWV (95% CI: 0.75–0.78 m/s) and 0.35 m/s for cfPWV (95% CI: 0.33–0.37 m/s), but sex differences in baPWV diminished with advancing age. Compared to Europe, baPWV was substantially higher in the Asian region (+1.83 m/s, P = 0.0014), whereas cfPWV was higher in the African region (+0.41 m/s, P < 0.0001) and differed more by country (highest in Poland, Russia, Iceland, France, and China; lowest in Spain, Belgium, Canada, Finland, and Argentina). High vs. other country income was associated with lower baPWV (−0.55 m/s, P = 0.048) and cfPWV (−0.41 m/s, P < 0.0001).
Interpretation
China and other Asian countries featured high PWV, which by known associations with central blood pressure and pulse pressure may partly explain higher Asian risk for intracerebral haemorrhage and small vessel stroke. Reference values provided may facilitate use of PWV as a marker of vascular ageing, for prediction of vascular risk and death, and for designing future therapeutic interventions.
Funding
This study was supported by the excellence initiative VASCage funded by the Austrian Research Promotion Agency, by the National Science Foundation of China, and the Science and Technology Planning Project of Hunan Province. Detailed funding information is provided as part of the Acknowledgments after the main text