    Optimising the life cycle energy performance of residential buildings

    Full text link
    A holistic approach to low-energy building design is essential to ensure that any efficiency improvement strategies provide a net energy benefit over the life of the building. Previous work by the authors has established a model for informing low-energy building design based on a comparison of the life cycle energy demand associated with a broad range of building assemblies. This model ranks assemblies based on their combined initial and recurrent embodied energy and operational energy demand. The current study applies this model to an actual residential building in order to demonstrate the application of the model for optimising a building’s life cycle energy performance. The aim of this study was to demonstrate how the availability of comparable energy performance information at the building design stage can be used to better optimise a building’s energy performance. The life cycle energy demand of the case study building, located in the temperate climate of Melbourne, Australia, was quantified using a comprehensive embodied energy assessment technique and TRNSYS thermal energy simulation software. The building was then modelled with variations to its external assemblies in an attempt to optimise its life cycle energy performance. The alternative assemblies chosen were those shown through the author’s previous modelling to result in the lowest life cycle energy demand for each building element. The best performing assemblies for each of the main external building elements were then combined into a best-case scenario to quantify the potential life cycle energy savings possible compared to the original building. The study showed that significant life cycle energy savings are possible through the modelling of individual building elements for the case study building. While these findings relate to a very specific case, this study demonstrates the application of a model for optimising building life cycle energy performance that may be applied more broadly during early-stage building design to optimise life cycle energy performance

    Validation of the use of Australian input-output data for building embodied energy simulation

    Full text link
    Traditional!y, the simulation of buildings has focused 011 operational energy consumption in an attempt to determine the potential for energy savings. Whilst operational energy of Australian buildings accounts for around 20% of total energy consumption nationally, embodied energy represents 20 to 50 times the annual operational energy of 1110st Australian buildings. Lower values have been shown through a number of studies that have analysed the embodied energy of buildings and their products, however these have now shown to be incomplete in system boundary. Many of these studies have used traditional embodied energy analysis methods, such as process analysis and input-output analysis, Hybrid embodied energy analysis methods have been developed, but these need to be compared and validated. This paper reports on preliminary work on this topic. The findings so far suggest that current best-practice methods are sufficiently accurate for most typical applications, but this is heavily dependant upon data quality and availability.<br /

    Embodied energy analysis of the refurbishment of a small detached building

    Full text link
    Energy efficient design principles and the minimisation of operational energy requirements have been demonstrated in the refurbishment of a small existing residential building. Significant thought has been given to these areas, together with an emphasis on the minimisation of resource consumption and material wastage. However, less consideration has been given to the embodied energy of the additional materials, components and systems required to meet these aims. The additional embodied energy may reduce the advantages of minimising the operational energy consumption by extending the energy payback period beyond the life of the building. In general, the embodied energy of buildings and their products has been found to be significant, when national average input-output data is used to fill gaps in traditional life-cycle assessment inventories. Through the use of an input-outputbased hybrid embodied energy analysis, the embodied energy of this refurbished building has increased by 63% compared to the existing building, showing the impact that filling the gaps in traditional inventories can have on energy payback periods.<br /

    Loss of very-long O-antigen chains optimizes capsule-mediated immune evasion by Salmonella enterica serovar Typhi.

    Get PDF
    UnlabelledExpression of capsular polysaccharides is a variable trait often associated with more-virulent forms of a bacterial species. For example, typhoid fever is caused by the capsulated Salmonella enterica serovar Typhi, while nontyphoidal Salmonella serovars associated with gastroenteritis are noncapsulated. Here we show that optimization of the immune evasive properties conferred by the virulence-associated (Vi) capsular polysaccharide involved an additional alteration to the cell envelope of S. Typhi, namely inactivation of the fepE gene, encoding the regulator of very-long O-antigen chains. Introduction of the capsule-encoding viaB locus into the nontyphoidal S. enterica serovar Typhimurium reduced complement deposition in vitro and intestinal inflammation in a mouse colitis model. However, both phenotypes were markedly enhanced when the viaB locus was introduced into an S. Typhimurium fepE mutant, which lacks very-long O-antigen chains. Collectively, these data suggest that during the evolution of the S. Typhi lineage, loss of very-long O-antigen chains by pseudogene formation was an adaptation to maximize the anti-inflammatory properties of the Vi capsular polysaccharide.ImportanceGenomic comparison illustrates that acquisition of virulence factors by horizontal gene transfer is an important contributor to the evolution of enteric pathogens. Acquisition of complex virulence traits commonly involves horizontal transfer of a large gene cluster, and integration of the gene cluster into the host genome results in the formation of a pathogenicity island. Acquisition of the virulence-associated (Vi) capsular polysaccharide encoded by SPI7 (Salmonella pathogenicity island 7) was accompanied in the human-adapted Salmonella enterica serovar Typhi by inactivation of the fepE gene, encoding the regulator of very-long O-antigen chains. We show that the resulting loss of very-long O-antigen chains was an important mechanism for maximizing immune evasion mediated by the Vi capsular polysaccharide. These data suggest that successful incorporation of a capsular polysaccharide requires changes in the cell envelope of the hosting pathogen

    Life-cycle energy analysis of building integrated photovoltaic systems (BiPVs) with heat recovery unit

    Full text link
    Building integrated photovoltaic (BiPV) systems generate electricity, but also heat, which is typically wasted and also reduces the efficiency of generation. A heat recovery unit can be combined with a BiPV system to take advantage of this waste heat, thus providing cogeneration. Two different photovoltaic (PV) cell types were combined with a heat recovery unit and analysed in terms of their life-cycle energy consumption to determine the energy payback period. A net energy analysis of these PV systems has previously been performed, but recent improvements in the data used for this study allow for a more comprehensive assessment of the combined energy used throughout the entire life-cycle of these systems to be performed. Energy payback periods between 4 and 16.5 years were found, depending on the BiPV system. The energy embodied in PV systems is significant, emphasised here due to the innovative use of national average input&ndash;output (I&ndash;O) data to fill gaps in traditional life-cycle inventories, i.e. hybrid analysis. These findings provide an insight into the net energy savings that are possible with a well-designed and managed BiPV system.<br /

    Very long O-antigen chains enhance fitness during Salmonella-induced colitis by increasing bile resistance.

    Get PDF
    Intestinal inflammation changes the luminal habitat for microbes through mechanisms that have not been fully resolved. We noticed that the FepE regulator of very long O-antigen chain assembly in the enteric pathogen Salmonella enterica serotype Typhimurium (S. Typhimurium) conferred a luminal fitness advantage in the mouse colitis model. However, a fepE mutant was not defective for survival in tissue, resistance to complement or resistance to polymyxin B. We performed metabolite profiling to identify changes in the luminal habitat that accompany S. Typhimurium-induced colitis. This analysis suggested that S. Typhimurium-induced colitis increased the luminal concentrations of total bile acids. A mutation in fepE significantly reduced the minimal inhibitory concentration (MIC) of S. Typhimurium for bile acids in vitro. Oral administration of the bile acid sequestrant cholestyramine resin lowered the concentrations of total bile acids in colon contents during S. Typhimurium infection and significantly reduced the luminal fitness advantage conferred by the fepE gene in the mouse colitis model. Collectively, these data suggested that very long O-antigen chains function in bile acid resistance of S. Typhimurium, a property conferring a fitness advantage during luminal growth in the inflamed intestine

    NASA Sea Ice Validation Program for the Defense Meteorological Satellite Program Special Sensor Microwave Imager

    Get PDF
    The history of the program is described along with the SSM/I sensor, including its calibration and geolocation correction procedures used by NASA, SSM/I data flow, and the NASA program to distribute polar gridded SSM/I radiances and sea ice concentrations (SIC) on CD-ROMs. Following a discussion of the NASA algorithm used to convert SSM/I radiances to SICs, results of 95 SSM/I-MSS Landsat IC comparisons for regions in both the Arctic and the Antarctic are presented. The Landsat comparisons show that the overall algorithm accuracy under winter conditions is 7 pct. on average with 4 pct. negative bias. Next, high resolution active and passive microwave image mosaics from coordinated NASA and Navy aircraft underflights over regions of the Beaufort and Chukchi seas in March 1988 were used to show that the algorithm multiyear IC accuracy is 11 pct. on average with a positive bias of 12 pct. Ice edge crossings of the Bering Sea by the NASA DC-8 aircraft were used to show that the SSM/I 15 pct. ice concentration contour corresponds best to the location of the initial bands at the ice edge. Finally, a summary of results and recommendations for improving the SIC retrievals from spaceborne radiometers are provided

    Heterogeneous Chemistry Involving Methanol in Tropospheric Clouds

    Get PDF
    In this report we analyze airborne measurements to suggest that methanol in biomass burning smoke is lost heterogeneously in clouds. When a smoke plume intersected a cumulus cloud during the SAFARI 2000 field project, the observed methanol gas phase concentration rapidly declined. Current understanding of gas and aqueous phase chemistry cannot explain the loss of methanol documented by these measurements. Two plausible heterogeneous reactions are proposed to explain the observed simultaneous loss and production of methanol and formaldehyde, respectively. If the rapid heterogeneous processing of methanol, seen in a cloud impacted by smoke, occurs in more pristine clouds, it could affect the oxidizing capacity of the troposphere on a global scale
    • …
    corecore