2,400 research outputs found

    Completeness and confusion in the identification of Lyman-break galaxies

    Get PDF
    We have carried out a study to simulate distant clusters of galaxies in deep ground-based optical images. We find that when model galaxies are added to deep images obtained with the William Herschel Telescope, there is considerable scatter of the recovered galaxy colours away from the model values; this scatter is larger than that expected from photometric errors and is significantly affected by confusion, due to ground-based seeing, between objects in the field. In typical conditions of \approx 1-arcsec seeing, the combination of confusion and incompleteness causes a considerable underestimation of the true surface density of z3z \approx 3 galaxies. We argue that the actual surface density of z3z \approx 3 galaxies may be several times greater than that estimated by previous ground-based studies, consistent with the surface density of such objects found in the HDF

    ENVIROSAT-2000 report: Federal agency satellite requirements

    Get PDF
    The requirement of Federal agencies, other than NOAA, for the data and services of civil operational environmental satellites (both polar orbiting and geostationary) are summarized. Agency plans for taking advantage of proposed future Earth sensing space systems, domestic and foreign, are cited also. Current data uses and future requirements are addressed as identified by each agency

    Influence of GABA and GABA-producing Lactobacillus brevis DPC 6108 on the development of diabetes in a streptozotocin rat model

    Get PDF
    peer-reviewedThe aim of this study was to investigate if dietary administration of γ-aminobutyric acid (GABA)-producing Lactobacillus brevis DPC 6108 and pure GABA exert protective effects against the development of diabetes in streptozotocin (STZ)-induced diabetic Sprague Dawley rats. In a first experiment, healthy rats were divided in 3 groups (n=10/group) receiving placebo, 2.6 mg/kg body weight (bw) pure GABA or L. brevis DPC 6108 (~109microorganisms). In a second experiment, rats (n=15/group) were randomised to five groups and four of these received an injection of STZ to induce type 1 diabetes. Diabetic and non-diabetic controls received placebo [4% (w/v) yeast extract in dH2O], while the other three diabetic groups received one of the following dietary supplements: 2.6 mg/kg bw GABA (low GABA), 200 mg/kg bw GABA (high GABA) or ~109 L. brevis DPC 6108. L. brevis DPC 6108 supplementation was associated with increased serum insulin levels (P0.05), compared with non-diabetic controls while all other diabetic groups displayed reduced diversity (P<0.05). L. brevis DPC 6108 attenuated hyperglycaemia induced by diabetes but additional studies are needed to understand the mechanisms involved in this reduction.The authors and their work were supported by the APC Microbiome Institute. The APC Microbiome Institute is funded by Science Foundation Ireland (SFI). This publication has emanated from research supported by a research grant from Science Foundation Ireland (SFI) under Grant Number SFI/12/RC/2273

    15-GHz variability of 9C sources

    Get PDF
    We present results from a 3-yr study of the 15-GHz variability of 51 9C sources. 48 of these sources make up a subsample of a larger one complete to 25 mJy in 9C, and as the sources are selected pseudo-randomly the results should be representative of the complete sample. 29 per cent of this subsample are found to be variable above the flux calibration uncertainties of ~6 per cent. 50 per cent of the flat-spectrum objects are variable whilst none of the steep-spectrum objects or the objects with convex spectra peaking below 5 GHz are variable. Nine of the objects studied have convex spectra and peak frequencies above 5 GHz; eight of these were found to vary at 15 GHz, suggesting that the high-frequency peaking class in this sample is largely populated by objects with jets aligned close to the line of sight whose emission is dominated by beamed components

    Characteristics of EGRET Blazars in the VLBA Imaging and Polarimetry Survey (VIPS)

    Get PDF
    We examine the radio properties of EGRET-detected blazars observed as part of the VLBA Imaging and Polarimetry Survey (VIPS). VIPS has a flux limit roughly an order of magnitude below the MOJAVE survey and most other samples that have been used to study the properties of EGRET blazars. At lower flux levels, radio flux density does not directly correlate with gamma-ray flux density. We do find that the EGRET-detected blazars tend to have higher brightness temperatures, greater core fractions, and possibly larger than average jet opening angles. A weak correlation is also found with jet length and with polarization. All of the well-established trends can be explained by systematically larger Doppler factors in the gamma-ray loud blazars, consistent with the measurements of higher apparent velocities found in monitoring programs carried out at radio frequencies above 10 GHz.Comment: 20 pages, 7 figures, accepted to Ap

    Identification of a plasma signature of psychotic disorder in children and adolescents from the Avon Longitudinal Study of Parents and Children (ALSPAC) cohort

    Get PDF
    The identification of an early biomarker of psychotic disorder is important as early treatment is associated with improved patient outcome. Metabolomic and lipidomic approaches in combination with multivariate statistical analysis were applied to identify plasma alterations in children (age 11) (38 cases vs 67 controls) and adolescents (age 18) (36 cases vs 117 controls) preceeding or coincident with the development of psychotic disorder (PD) at age 18 in the Avon Longitudinal Study of Parents and Children (ALSPAC). Overall, 179 lipids were identified at age 11, with 32 found to be significantly altered between the control and PD groups. Following correction for multiple comparisons, 8 of these lipids remained significant (lysophosphatidlycholines (LPCs) LPC(18:1), LPC(18:2), LPC(20:3); phosphatidlycholines (PCs) PC(32:2; PC(34:2), PC(36:4), PC(0-34-3) and sphingomyelin (SM) SM(d18:1/24:0)), all of which were elevated in the PD group. At age 18, 23 lipids were significantly different between the control and PD groups, although none remained significant following correction for multiple comparisons. In conclusion, the findings indicate that the lipidome is altered in the blood during childhood, long before the development of psychotic disorder. LPCs in particular are elevated in those who develop PD, indicating inflammatory abnormalities and altered phospholipid metabolism. These findings were not found at age 18, suggesting there may be ongoing alterations in the pathophysiological processes from prodrome to onset of PD

    Relaxin, a pleiotropic vasodilator for the treatment of heart failure

    Get PDF
    Relaxin is a naturally occurring peptide hormone that plays a central role in the hemodynamic and renovascular adaptive changes that occur during pregnancy. Triggering similar changes could potentially be beneficial in the treatment of patients with heart failure. The effects of relaxin include the production of nitric oxide, inhibition of endothelin, inhibition of angiotensin II, production of VEGF, and production of matrix metalloproteinases. These effects lead to systemic and renal vasodilation, increased arterial compliance, and other vascular changes. The recognition of this has led to the study of relaxin for the treatment of heart failure. An initial pilot study has shown favorable hemodynamic effects in patients with heart failure, including reduction in ventricular filling pressures and increased cardiac output. The ongoing RELAX-AHF clinical program is designed to evaluate the effects of relaxin on the symptoms and outcomes in a large group of patients admitted to hospital for acute heart failure. This review will summarize both the biology of relaxin and the data supporting its potential efficacy in human heart failure

    Worsening renal function in patients hospitalised for acute heart failure: clinical implications and prognostic significance.

    Get PDF
    BACKGROUND: Renal function is a powerful prognostic variable in patients with heart failure (HF). Hospitalisations for acute HF (AHF) may be associated with further worsening of renal function (WRF). METHODS AND RESULTS: We analysed the clinical significance of WRF in 318 consecutive patients admitted at our institute for AHF. WRF was defined as the occurrence, at any time during the hospitalisation, of both a > or =25% and a > or =0.3 mg/dL increase in serum creatinine (s-Cr) from admission (WRF-Abs-%). RESULTS: Patients were followed for 480+/-363 days. Fifty-three patients (17%) died and 132 (41%) were rehospitalised for HF. WRF-Abs-% occurred in 107 (34%) patients. At multivariable survival analysis, WRF-Abs-% was an independent predictor of death or HF rehospitalisation (adjusted HR, 1.47; 95%CI, 1.13-1.81; p=0.024). The independent predictors of WRF-Abs-%, evaluated using multivariable logistic regression, were history of chronic kidney disease (p=0.002), LV ejection fraction (p=0.012), furosemide daily dose (p=0.03) and NYHA class (p=0.05) on admission. CONCLUSION: WRF is a frequent finding in patients hospitalised for AHF and is associated with a poor prognosis. Severity of HF and daily furosemide dose are the most important predictors of the occurrence of WRF

    The first GCT camera for the Cherenkov Telescope Array

    Full text link
    The Gamma Cherenkov Telescope (GCT) is proposed to be part of the Small Size Telescope (SST) array of the Cherenkov Telescope Array (CTA). The GCT dual-mirror optical design allows the use of a compact camera of diameter roughly 0.4 m. The curved focal plane is equipped with 2048 pixels of ~0.2{\deg} angular size, resulting in a field of view of ~9{\deg}. The GCT camera is designed to record the flashes of Cherenkov light from electromagnetic cascades, which last only a few tens of nanoseconds. Modules based on custom ASICs provide the required fast electronics, facilitating sampling and digitisation as well as first level of triggering. The first GCT camera prototype is currently being commissioned in the UK. On-telescope tests are planned later this year. Here we give a detailed description of the camera prototype and present recent progress with testing and commissioning.Comment: In Proceedings of the 34th International Cosmic Ray Conference (ICRC2015), The Hague, The Netherlands. All CTA contributions at arXiv:1508.0589

    Vasodilators in the treatment of acute heart failure: what we know, what we don’t

    Get PDF
    Although we have recently witnessed substantial progress in management and outcome of patients with chronic heart failure, acute heart failure (AHF) management and outcome have not changed over almost a generation. Vasodilators are one of the cornerstones of AHF management; however, to a large extent, none of those currently used has been examined by large, placebo-controlled, non-hemodynamic monitored, prospective randomized studies powered to assess the effects on outcomes, in addition to symptoms. In this article, we will discuss the role of vasodilators in AHF trying to point out which are the potentially best indications to their administration and which are the pitfalls which may be associated with their use. Unfortunately, most of this discussion is only partially evidence based due to lack of appropriate clinical trials. In general, we believe that vasodilators should be administered early to AHF patients with normal or high blood pressure (BP) at presentation. They should not be administered to patients with low BP since they may cause hypotension and hypoperfusion of vital organs, leading to renal and/or myocardial damage which may further worsen patients’ outcome. It is not clear whether vasodilators have a role in either patients with borderline BP at presentation (i.e., low-normal) or beyond the first 1–2 days from presentation. Given the limitations of the currently available clinical trial data, we cannot recommend any specific agent as first line therapy, although nitrates in different formulations are still the most widely used in clinical practice
    corecore