258 research outputs found

    Extracting fetal heart beats from maternal abdominal recordings: Selection of the optimal principal components

    Get PDF
    This study presents a systematic comparison of different approaches to the automated selection of the principal components (PC) which optimise the detection of maternal and fetal heart beats from non-invasive maternal abdominal recordings. A public database of 75 4-channel non-invasive maternal abdominal recordings was used for training the algorithm. Four methods were developed and assessed to determine the optimal PC: (1) power spectral distribution, (2) root mean square, (3) sample entropy, and (4) QRS template. The sensitivity of the performance of the algorithm to large-amplitude noise removal (by wavelet de-noising) and maternal beat cancellation methods were also assessed. The accuracy of maternal and fetal beat detection was assessed against reference annotations and quantified using the detection accuracy score F1 [2*PPV*Se / (PPV + Se)], sensitivity (Se), and positive predictive value (PPV). The best performing implementation was assessed on a test dataset of 100 recordings and the agreement between the computed and the reference fetal heart rate (fHR) and fetal RR (fRR) time series quantified. The best performance for detecting maternal beats (F1 99.3%, Se 99.0%, PPV 99.7%) was obtained when using the QRS template method to select the optimal maternal PC and applying wavelet de-noising. The best performance for detecting fetal beats (F1 89.8%, Se 89.3%, PPV 90.5%) was obtained when the optimal fetal PC was selected using the sample entropy method and utilising a fixed-length time window for the cancellation of the maternal beats. The performance on the test dataset was 142.7 beats2/min2 for fHR and 19.9 ms for fRR, ranking respectively 14 and 17 (out of 29) when compared to the other algorithms presented at the Physionet Challenge 2013

    Grey-box Modelling of a Household Refrigeration Unit Using Time Series Data in Application to Demand Side Management

    Get PDF
    This paper describes the application of stochastic grey-box modeling to identify electrical power consumption-to-temperature models of a domestic freezer using experimental measurements. The models are formulated using stochastic differential equations (SDEs), estimated by maximum likelihood estimation (MLE), validated through the model residuals analysis and cross-validated to detect model over-fitting. A nonlinear model based on the reversed Carnot cycle is also presented and included in the modeling performance analysis. As an application of the models, we apply model predictive control (MPC) to shift the electricity consumption of a freezer in demand response experiments, thereby addressing the model selection problem also from the application point of view and showing in an experimental context the ability of MPC to exploit the freezer as a demand side resource (DSR).Comment: Submitted to Sustainable Energy Grids and Networks (SEGAN). Accepted for publicatio

    Phthalate plasticizers covalently linked to PVC \u3ci\u3evia\u3c/i\u3e copper-free or copper catalyzed axide-alkyne cycloadditions

    Get PDF
    Plasticization of PVC was carried out by covalently linking phthalate derivatives via copper-free (thermal) or copper catalyzed azide-alkyne cycloadditions. Di(2-ethylhexyl) phthalate derivatives (DEHP-ether and DEHP-ester) were synthesized and appended to PVC at two different densities. The glass transition temperatures of the modified PVC decreased with increasing content of plasticizer. PVC-DEHP-ether gave lower glass transition temperatures than PVC-DEHP-ester, reflecting the enhanced flexibility of the ether versus ester linker

    Recurring patterns in stationary intervals of abdominal uterine electromyograms during gestation

    Get PDF
    Abdominal uterine electromyograms (uEMG) studies have focused on uterine contractions to describe the evolution of uterine activity and preterm birth (PTB) prediction. Stationary, non-contracting uEMG has not been studied. The aim of the study was to investigate the recurring patterns in stationary uEMG, their relationship with gestation age and PTB, and PTB predictivity. A public database of 300 (38 PTB) three-channel (S1-S3) uEMG recordings of 30 min, collected between 22 and 35 weeks' gestation, was used. Motion and labour contraction-free intervals in uEMG were identified as 5-min weak-sense stationarity intervals in 268 (34 PTB) recordings. Sample entropy (SampEn), percentage recurrence (PR), percentage determinism (PD), entropy (ER), and maximum length (L MAX) of recurrence were calculated and analysed according to the time to delivery and PTB. Random time series were generated by random shuffle (RS) of actual data. Recurrence was present in actual data (p<0.001) but not RS. In S3, PR (p<0.005), PD (p<0.01), ER (p<0.005), and L MAX (p<0.05) were higher, and SampEn lower (p<0.005) in PTB. Recurrence indices increased (all p<0.001) and SampEn decreased (p<0.01) with decreasing time to delivery, suggesting increasingly regular and recurring patterns with gestation progression. All indices predicted PTB with AUC≥0.62 (p<0.05). Recurring patterns in stationary non-contracting uEMG were associated with time to delivery but were relatively poor predictors of PTB

    Yellow laser performance of Dy3+^{3+} in co-doped Dy,Tb:LiLuF4_4

    Full text link
    We present laser results obtained from a Dy3+^{3+}-Tb3+^{3+} co-doped LiLuF4_{4} crystal, pumped by a blue emitting InGaN laser diode, aiming for the generation of a compact 578 nm source. We exploit the yellow Dy3+^{3+} transition 4^{4}F9/2_{9/2} âźą\Longrightarrow 6^{6}H13/2_{13/2} to generate yellow laser emission. The lifetime of the lower laser level is quenched via energy transfer to co-doped Tb3+^{3+} ions in the fluoride crystal. We report the growth technique, spectroscopic study and room temperature continuous wave (cw) laser results in a hemispherical cavity at 574 nm and with a highly reflective output coupler at 578 nm. A yellow laser at 578 nm is very relevant for metrological applications, in particular for pumping of the forbidden 1^{1}S0âźą3_{0} \Longrightarrow ^{3}P0_{0} Ytterbium clock transition, which is recommended as a secondary representation of the second in the international system (SI) of units. This paper was published in Optics Letters and is made available as an electronic reprint with the permission of OSA. The paper can be found at the following URL on the OSA website: http://dx.doi.org/10.1364/OL.39.006628. Systematic or multiple reproduction or distribution to multiple locations via electronic or other means is prohibited and is subject to penalties under law.Comment: 8 pages, 5 figure

    Novel polymer coupling chemistry based upon latent cysteine-like residues and thiazolidine chemistry

    Get PDF
    Chain end functional polymers were prepared via reversible addition–fragmentation transfer (RAFT) polymerization techniques that were further chain extended with acrylonitrile. Under reducing conditions, latent cysteine-like residues were exposed at the chain ends. A variety of reduction conditions were explored and base polymers were then tethered together via thiazolidine chemistry

    Poly(N-isopropylacrylamide) hydrogels for storage and delivery of reagents to paper-based analytical devices

    Get PDF
    The thermally responsive hydrogel N,N\u27-methylenebisacrylamide-cross-linked poly(N-isopropylacrylamide) (PNIPAM) was developed and evaluated as a reagent storage and delivery system for microfluidic paper-based analytical devices (microPADs). PNIPAM was shown to successfully deliver multiple solutions to microPADs in specific sequences or simultaneously in laminar-flow configuration and was found to be suitable for delivering four classes of reagents to the devices: Small molecules, enzymes, antibodies and DNA. PNIPAM was also able to successfully deliver a series of standard glucose solutions to microPADs equipped to perform a colorimetric glucose assay. The results of these tests were used to produce an external calibration curve, which in turn was used to determine the concentration of glucose in sample solutions. Finally, PNIPAM was used to store the enzyme horseradish peroxidase for 35 days under ambient conditions with no significant loss of activity. The combination of PNIPAM and microPADs may allow for more complex assays to be performed on paper-based devices, facilitate the preparation of external calibration curves in the field, and extend the shelf life of microPADs by stabilizing reagents in an easy-to-use format

    Biomolecule Detection \u3cem\u3evia\u3c/em\u3e Target Mediated Nanoparticle Aggregation and Dielectrophoretic Impedance Measurement

    Get PDF
    A new biosensing system is described that is based on the aggregation of nanoparticles by a target biological molecule and dielectrophoretic impedance measurement of these aggregates. The aggregation process was verified within a microchannel via fluorescence microscopy, demonstrating that this process can be used in a real time sensor application. Positive dielectrophoresis is employed to capture the nanoparticle aggregates at the edge of thin film electrodes, where their presence is detected either by optical imaging via fluorescence microscopy or by measuring the change in electrical impedance between adjacent electrodes. The electrical detection mechanism demonstrates the potential for this method as a micro total analysis system (mTAS)

    Thermally Driven Assembly of Nanoparticles in Polymer Matrices

    Full text link

    Prevalence of latent tuberculosis, syphilis, hepatitis B and C among asylum seekers in Malta

    Get PDF
    Background: In the last few years, Malta has witnessed increasing immigration flows from the Libyan coasts. Public health policies are focused on screening migrants for tuberculosis, whereas no systematic actions against STIs are implemented. The aim of this study is to define the epidemiological profile of asylum seekers in Malta as regards syphilis, hepatitis B, C and latent tuberculosis, thus supporting screening policies. Methods: Five hundred migrants living in open centres were screened between December 2010 and June 2011. Results: 83.2% of people was from Somalia, 81.2% males, average age 26.5 years. The tuberculin skin test (TST) was positive in 225 migrants (45%). Latent syphilis was diagnosed in 11 migrants, hepatitis C in 3 and 31 migrants were HBsAg positive. Conclusion: Systematic screening for asymptomatic migrants in Malta is not recommended for hepatitis C and syphilis, given the low prevalence observed. On the contrary, it should be considered for hepatitis B. TST could be indicated as the first step of a two step screening for migrants from countries with high TB incidence. Efficacy and cost-effectiveness could be achieved by further targeting screening to specific subgroups at higher risk of reactivation, such as people living with HIV and subjects affected by chronic diseases.peer-reviewe
    • …
    corecore