54 research outputs found

    Covered self-expandable metal stents for pancreatic duct stricture: a systematic review and meta-analysis

    Get PDF
    Background and study aims Placement of a covered (C)-self-expandable metal stent (SEMS) has been recently investigated as an alternative endoscopic treatment for main pancreatic duct stricture (MPDS) in chronic pancreatitis. Our aim was to carry out a systematic review and meta-analysis of studies quantifying efficacy and safety of C-SEMSs in the management of MPDS.Methods A multiple database search was performed, including MEDLINE, Embase and Cochrane Library, from January 2000 to September 2020, to identify studies reporting the efficacy and safety of C-SEMSs in patients with MPDS. Stricture and pain resolution were investigated. Other outcomes included technical success, stent migration, stricture recurrence and need for repeated stent placement. Pancreatitis, severe abdominal pain requiring stent removal and de-novo stricture were recorded as complications.Results Nineteen studies were identified, which included a total of 300 patients. C-SEMSs showed a pooled stricture resolution rate of 91 % [95 % confidence interval (CI), 85 %-96 %] and a pooled pain resolution rate of 92 % (95 % CI, 85 %-98 %). The pooled proportion for stricture recurrence was equal to 6 % (95 % CI, 1 %-14 %), while stent migration occurred in 33 of 300 patients, the pooled proportion being 7 % (95 % CI 1 %-15 %). The pooled mean stent duration was 133 days (95 % CI, 100-166 days). The most common complication was pancreatitis (3 %, 95 % CI 0 %-8 %), while de-novo stricture pooled proportion was 2 % (95 % CI, 0 %-5 %).Conclusions C-SEMSs are effective and safe in the treatment of MPDS. However, there is a significant need for further high-quality, well-designed studies to produce evidence-based data on short and long-term efficacy, safety, costs of C-SEMSs, and also optimal stent duration

    Treatment of post-cholecystectomy biliary strictures with fully-covered self-expanding metal stents - results after 5 years of follow-up

    Get PDF
    BACKGROUND: Endoscopic treatment of post-cholecystectomy biliary strictures (PCBS) with multiple plastic biliary stents placed sequentially is a minimally invasive alternative to surgery but requires multiple interventions. Temporary placement of a single fully-covered self-expanding metal stent (FCSEMS) may offer safe and effective treatment with fewer re-interventions. Long-term effectiveness of treatment with FCSEMS to obtain PCBS resolution has not yet been studied. METHODS: In this prospective multi-national study in patients with symptomatic benign biliary strictures (N = 187) due to various etiologies received a FCSEMS with scheduled removal at 6-12 months and were followed for 5 years. We report here long-term outcomes of the subgroup of patients with PCBS (N = 18). Kaplan Meier analyses assessed long-term freedom from re-stenting. Adverse events were documented. RESULTS: Endoscopic removal of the FCSEMS was achieved in 83.3% (15/18) of patients after median indwell of 10.9 (range 0.9-13.8) months. In the remaining 3 patients (16.7%), the FCSEMS spontaneously migrated and passed without complications. At the end of FCSEMS indwell, 72% (13/18) of patients had stricture resolution. At 5 years after FCSEMS removal, 84.6% (95% CI 65.0-100.0%) of patients who had stricture resolution at FCSEMS removal remained stent-free. In addition, at 75 months after FCSEMS placement, the probability of remaining stent-free was 61.1% (95% CI 38.6-83.6%) for all patients. Stent or removal related serious adverse events occurred in 38.9% (7/18) all resolved without sequalae. CONCLUSIONS: In patients with symptomatic PCBS, temporary placement of a single FCSEMS intended for 10-12 months indwell is associated with long-term stricture resolution up to 5 years. Temporary placement of a single FCSEMS may be considered for patients with PCBS not involving the main hepatic confluence. TRIAL REGISTRATION NUMBERS: NCT01014390; CTRI/2012/12/003166; Registered 17 November 2009

    Second-generation colon capsule endoscopy compared with colonoscopy

    Get PDF
    Colon capsule endoscopy (CCE) represents a noninvasive technology that allows visualization of the colon without requiring sedation and air insufflation. A second-generation colon capsule endoscopy system (PillCam Colon 2) (CCE-2) was developed to increase sensitivity for colorectal polyp detection compared with the first-generation system. OBJECTIVE: To assess the feasibility, accuracy, and safety of CCE-2 in a head-to-head comparison with colonoscopy. DESIGN AND SETTING: Prospective, multicenter trial including 8 European sites. PATIENTS: This study involved 117 patients (mean age 60 years). Data from 109 patients were analyzed. INTERVENTION: CCE-2 was prospectively compared with conventional colonoscopy as the criterion standard for the detection of colorectal polyps that are >/=6 mm or masses in a cohort of patients at average or increased risk of colorectal neoplasia. Colonoscopy was independently performed within 10 hours after capsule ingestion or on the next day. MAIN OUTCOME MEASUREMENTS: CCE-2 sensitivity and specificity for detecting patients with polyps >/=6 mm and >/=10 mm were assessed. Capsule-positive but colonoscopy-negative cases were counted as false positive. Capsule excretion rate, level of bowel preparation, and rate of adverse events also were assessed. RESULTS: Per-patient CCE-2 sensitivity for polyps >/=6 mm and >/=10 mm was 84% and 88%, with specificities of 64% and 95%, respectively. All 3 invasive carcinomas were detected by CCE-2. The capsule excretion rate was 88% within 10 hours. Overall colon cleanliness for CCE-2 was adequate in 81% of patients. LIMITATIONS: Not unblinding the CCE-2 results at colonoscopy; heterogenous patient population; nonconsecutive patients. CONCLUSION: In this European, multicenter study, CCE-2 appeared to have a high sensitivity for the detection of clinically relevant polypoid lesions, and it might be considered an adequate tool for colorectal imaging

    Antireflux Transoral Incisionless Fundoplication Using EsophyX: 12-Month Results of a Prospective Multicenter Study

    Get PDF
    BACKGROUND: A novel transoral incisionless fundoplication (TIF) procedure using the EsophyX system with SerosaFuse fasteners was designed to reconstruct a full-thickness valve at the gastroesophageal junction through tailored delivery of multiple fasteners during a single-device insertion. The safety and efficacy of TIF for treating gastroesophageal reflux disease (GERD) were evaluated in a prospective multicenter trial. METHODS: Patients (n = 86) with chronic GERD treated with proton pump inhibitors (PPIs) were enrolled. Exclusion criteria included an irreducible hiatal hernia > 2 cm. RESULTS: The TIF procedure (n = 84) reduced all hiatal hernias (n = 49) and constructed valves measuring 4 cm (2-6 cm) and 230 degrees (160 degrees -300 degrees ). Serious adverse events consisted of two esophageal perforations upon device insertion and one case of postoperative intraluminal bleeding. Other adverse events were mild and transient. At 12 months, aggregate (n = 79) and stratified Hill grade I tight (n = 21) results showed 73% and 86% of patients with >or=50% improvement in GERD health-related quality of life (HRQL) scores, 85% discontinuation of daily PPI use, and 81% complete cessation of PPIs; 37% and 48% normalization of esophageal acid exposure; 60% and 89% hiatal hernia reduction; and 62% and 80% esophagitis reduction, respectively. More than 50% of patients with Hill grade I tight valves had a normalized cardia circumference. Resting pressure of the lower esophageal sphincter (LES) was improved significantly (p < 0.001), by 53%. EsophyX-TIF cured GERD in 56% of patients based on their symptom reduction and PPI discontinuation. CONCLUSION: The 12-month results showed that EsophyX-TIF was safe and effective in improving quality of life and for reducing symptoms, PPI use, hiatal hernia, and esophagitis, as well as increasing the LES resting pressure and normalizing esophageal pH and cardia circumference in chronic GERD patients.Journal ArticleMulticenter StudyResearch Support, Non-U.S. Gov'tinfo:eu-repo/semantics/publishe

    Prevalence and characteristics of serrated lesions of the colorectum in Italy: A multicentre prospective cohort study

    No full text
    Serrated lesions are recognized as important contributors to colorectal cancer incidence. We aimed to prospectively assess the prevalence of serrated lesions and identify potential predictors of these lesions during colonoscopy in an Italian population

    Colon capsule endoscopy: What we know and what we would like to know

    No full text
    Colonoscopy is usually perceived as an invasive and potentially painful procedure, being also affected by a small, but definite, risk of major complications (cardiopulmonary complications, perforation, hemorrhage) and even mortality. To improve both acceptability and safety, PillCam Colon Capsule Endoscopy (CCE) (Given Imaging Ltd, Yoqneam, Israel) has been developed. CCE represents a non-invasive technique that is able to explore the colon without sedation and air insufflation. The Second Generation of Colon Capsule Endoscopy (PillCam Colon 2) (CCE-2) was proven to be an accurate tool to detect colonic neoplastic lesions when used in average risk individuals. To date, the evidence supports the use of CCE-2 in case of colonoscopy failure, in patients unwilling to perform colonoscopy and when colonoscopy is contraindicated. Other potential applications, such as colorectal cancer screening or diagnostic surveillance of inflammatory bowel disease need to be clarified. In this paper, the current "state of the art", potential application of CCE and future needs are evaluated
    • …
    corecore