268 research outputs found

    3-Dimensional Mapping and Radiofrequency Ablation of Atrial Flutter in a Patient with Interrupted Inferior Vena Cava

    Full text link
    The presence of isolated interrupted inferior vena cava (IVC) is very rare. Though the occurrence of typical atrial flutter in this setting has recently been described, the use of 3-dimensional activation mapping to aid the management of such patients has not yet been described. We report the successful ablation of this arrhythmia in a 63-year-old woman using the superior route through the internal jugular vein with the help of a mapping system.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/46349/1/10840_2005_Article_4512.pd

    Renal transplantation for lupus nephritis: non-adherence and graft survival

    Get PDF
    Objectives: Poor adherence to immunosuppressive treatment is common in patients with systemic lupus erythematosus and may identify those with lupus nephritis (LN) who have a poorer prognosis. Non-adherence has also been reported to be a potential adverse outcome predictor in renal transplantation (rTp). We investigated whether non-adherence is associated with increased rTp graft rejection and/or failure in patients with LN. Methods: Patients with LN undergoing rTp in two major London hospitals were retrospectively included. Medical and electronic records were reviewed for documented concerns of non-adherence as well as laboratory biochemical drug levels. The role of non-adherence and other potential predictors of graft rejection/failure including demographics, comorbidities, age at systemic lupus erythematosus and LN diagnosis, type of LN, time on dialysis prior to rTp and medication use were investigated using logistic regression. Results: Out of 361 patients with LN, 40 had rTp. During a median follow-up of 8.7 years, 17/40 (42.5%) of these patients had evidence of non-adherence. A total of 12 (30.0%) patients experienced graft rejection or failure or both. In the adherent group 2/23 (8.7%) had graft rejection, whilst in the non-adherent this rose to 5/17 (29.4%, p = 0.11). Graft failure was seen in 5/23 (21.7%) patients from the adherent group and 4/17 (23.5%) in the non-adherent group (p = 0.89). Non-adherent patients had a trend towards increased graft rejection, hazard ratio 4.38, 95% confidence interval = 0.73–26.12, p = 0.11. Patients who spent more time on dialysis prior to rTp were more likely to be adherent to medication, p = 0.01. Conclusion: Poor adherence to immunosuppressive therapy is common and has been shown to associate with a trend towards increased graft failure in patients with LN requiring rTp. This is the first paper to report that shorter periods on dialysis prior to transplantation might lead to increased non-adherence in lupus patients

    Impact of pre-transplant time on dialysis on survival in patients with lupus nephritis

    Get PDF
    Lupus nephritis (LN) is an important cause of morbidity and mortality in patients with systemic lupus erythematosus (SLE) often leading to end-stage renal failure (ESRF) and necessitating renal transplantation (rTp). Optimal timing of rTp in SLE patients with ESRF is uncertain and could potentially affect survival. We investigated the time spent on dialysis before rTp and survival following rTp in a cohort of SLE patients. Retrospective analysis of all adult SLE patients receiving rTp over a 40-year period (1975–2015) in two tertiary UK centres. Cox proportional hazard regression and receiver operator curves (ROC) were used to determine the risk associated with time on dialysis before rTp and other potential predictors. Forty patients (age 35 ± 11 years, 34 female, 15 Caucasian, 15 Afro–Caribbean and 10 South Asian) underwent rTp. During a median follow-up of 104 months (IQR 80,145), eight (20%) patients died and the 5-year survival was 95%. Univariate analysis identified time on dialysis prior to rTp as the only potentially modifiable risk predictor of survival with a hazard ratio of 1.013 for each additional month spent on dialysis (95% CI = 1.001–1.026, p = 0.03). ROC curves demonstrated that > 24 months on dialysis had an adverse effect with sensitivity of 0.875 and specificity 0.500 for death. No other modifiable predictors were significantly associated with mortality, indicating that time on dialysis had an independent effect. Increased time on dialysis pre-transplantation is an independent modifiable risk factor of mortality in this cohort of patients with lupus nephritis

    Death with functioning kidney transplant: an obituarial analysis

    Get PDF
    Death with a functioning kidney graft (DWFG) is now a major cause of graft loss after renal transplantation, occurring in up to 40% of cases. Its occurrence provides insight into the medical care of subjects with a functioning kidney transplant. In this study, we used the time to DWFG as an endpoint, to test whether improved medical care has contributed to better kidney transplant outcomes. We used single-center data from the Milwaukee Regional Medical Center and Froedtert Hospital, on kidney-only transplants from 1969 through 2005. A total of 3,157 kidney transplants were done at our center during this time. There were 714 deaths with functioning kidney. We also recorded the major causes of DWFG over the time period from 1969 through 2005 divided into 3 epochs. The data were analyzed as a serial collection of yearly obituaries. The time to DWFG has increased to 10 years despite a 20-year increase in the mean age of transplant recipients over the same time period. Better pre-transplant evaluation, improved treatments for hypertension and hyperlipidemia, improved management of acute myocardial infarction, superior immunosuppressive protocols and better prophylaxis and treatment of infectious diseases have all likely contributed to this trend

    Signal-averaged P wave analysis for delineation of interatrial conduction – Further validation of the method

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The study was designed to investigate the effect of different measuring methodologies on the estimation of P wave duration. The recording length required to ensure reproducibility in unfiltered, signal-averaged P wave analysis was also investigated. An algorithm for automated classification was designed and its reproducibility of manual P wave morphology classification investigated.</p> <p>Methods</p> <p>Twelve-lead ECG recordings (1 kHz sampling frequency, 0.625 <it>μ</it>V resolution) from 131 healthy subjects were used. Orthogonal leads were derived using the inverse Dower transform. Magnification (100 times), baseline filtering (0.5 Hz high-pass and 50 Hz bandstop filters), signal averaging (10 seconds) and bandpass filtering (40–250 Hz) were used to investigate the effect of methodology on the estimated P wave duration. Unfiltered, signal averaged P wave analysis was performed to determine the required recording length (6 minutes to 10 s) and the reproducibility of the P wave morphology classification procedure. Manual classification was carried out by two experts on two separate occasions each. The performance of the automated classification algorithm was evaluated using the joint decision of the two experts (i.e., the consensus of the two experts).</p> <p>Results</p> <p>The estimate of the P wave duration increased in each step as a result of magnification, baseline filtering and averaging (100 ± 18 vs. 131 ± 12 ms; P < 0.0001). The estimate of the duration of the bandpass-filtered P wave was dependent on the noise cut-off value: 119 ± 15 ms (0.2 <it>μ</it>V), 138 ± 13 ms (0.1 <it>μ</it>V) and 143 ± 18 ms (0.05 <it>μ</it>V). (P = 0.01 for all comparisons).</p> <p>The mean errors associated with the P wave morphology parameters were comparable in all segments analysed regardless of recording length (95% limits of agreement within 0 ± 20% (mean ± SD)). The results of the 6-min analyses were comparable to those obtained at the other recording lengths (6 min to 10 s).</p> <p>The intra-rater classification reproducibility was 96%, while the interrater reproducibility was 94%. The automated classification algorithm agreed with the manual classification in 90% of the cases.</p> <p>Conclusion</p> <p>The methodology used has profound effects on the estimation of P wave duration, and the method used must therefore be validated before any inferences can be made about P wave duration. This has implications in the interpretation of multiple studies where P wave duration is assessed, and conclusions with respect to normal values are drawn.</p> <p>P wave morphology and duration assessed using unfiltered, signal-averaged P wave analysis have high reproducibility, which is unaffected by the length of the recording. In the present study, the performance of the proposed automated classification algorithm, providing total reproducibility, showed excellent agreement with manually defined P wave morphologies.</p

    Comparison of glucose tolerance in renal transplant recipients and hemodialysis patients

    Get PDF
    BACKGROUND: Impaired glucose tolerance is a risk factor for atherosclerosis in hemodialysis patients and renal transplant recipients. METHODS: To check the relationship of impaired glucose tolerance with the other atherosclerotic risk factors, fasting blood sugar and the standard two hour glucose tolerance test, serum tryglyceride, serum cholesterol, cyclosporine through level (in renal tranpslant recipients) and hemoglobin A1C were measured in 55 stable renal transplant recipients, 55 hemodialysis patients and 55 healthy controls with similar demographic characteristics. Patients with diabetes mellitus and propranolol consumers were excluded. The mean age and female to male ratio were 39 +/- 7 years and 23/22, respectively. RESULTS: Four of the renal transplant recipients and twelve of the hemodialysis patients had impaired glucose tolerance. Significant linear correlation was observed with body mass index and IGT only in hemodialysis patients (r = 0.4, p = 0.05). Glucose tolerance also had a significant correlation with triglyceride levels (217.2 +/- 55 mg/dl in hemodialysis patients vs. 214.3 +/- 13 mg/dl in renal transplant recipients and 100.2 +/- 18 mg/dl in control groups, p = 0.001). The glucose tolerance had significant relationship with higher serum cholesterol levels only in the renal transplant recipients (269.7 +/- 54 in renal transplant recipients vs. 199.2 +/- 36.6 mg/dl in hemodialysis and 190.5 +/- 34 mg/dl in control groups, p = 0.0001). In the renal transplant recipients, a linear correlation was observed with glucose tolerance and both the serum cyclosporine level (r = 0.9, p = 0.001) and the hemoglobin A1C concentration (6.2 +/- 0.9 g/dl). The later correlation was also observed in the hemodialysis patients (6.4 +/- 0.7 g/dl; r = 67, p = 0.001). CONCLUSIONS: We conclude that although fasting blood sugar is normal in non-diabetic renal transplant and hemodialysis patients, impaired glucose tolerance could be associated with the other atherosclerotic risk factors

    Can we improve outcomes in AF patients by early therapy?

    Get PDF
    Atrial fibrillation affects at least 1% of the population and causes marked society-wide morbidity and mortality. Current management of atrial fibrillation including antithrombotic therapy and management of concomitant conditions in all patients, rate control therapy in most patients, and rhythm control therapy in patients with severe atrial fibrillation-related symptoms can alleviate atrial fibrillation-related symptoms but can neither effectively prevent recurrent atrial fibrillation nor suppress atrial fibrillation-related complications. Hence, there is a need for better therapy of atrial fibrillation

    Kidney organ donation: developing family practice initiatives to reverse inertia

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Kidney transplantation is associated with greater long term survival rates and improved quality of life compared with dialysis. Continuous growth in the number of patients with kidney failure has not been matched by an increase in the availability of kidneys for transplantation. This leads to long waiting lists, higher treatment costs and negative health outcomes.</p> <p>Discussion</p> <p>Misunderstandings, public uncertainty and issues of trust in the medical system, that limit willingness to be registered as a potential donor, could be addressed by community dissemination of information and new family practice initiatives that respond to individuals' personal beliefs and concerns regarding organ donation and transplantation.</p> <p>Summary</p> <p>Tackling both personal and public inertia on organ donation is important for any community oriented kidney donation campaign.</p

    Assessment of atrial regional and global electromechanical function by tissue velocity echocardiography: a feasibility study on healthy individuals

    Get PDF
    BACKGROUND: The appropriate evaluation of atrial electrical function is only possible by means of invasive electrophysiology techniques, which are expensive and therefore not suitable for widespread use. Mechanical atrial function is mainly determined from atrial volumes and volume-derived indices that are load-dependent, time-consuming and difficult to reproduce because they are observer-dependent. AIMS: To assess the feasibility of tissue velocity echocardiography (TVE) to evaluate atrial electromechanical function in young, healthy volunteers. SUBJECTS AND METHODS: We studied 37 healthy individuals: 28 men and nine women with a mean age of 29 years (range 20–47). Standard two-dimensional (2-D) and Doppler echocardiograms with superimposed TVE images were performed. Standard echocardiographic images were digitized during three consecutive cardiac cycles in cine-loop format for off-line analysis. Several indices of regional atrial electrical and mechanical function were derived from both 2-D and TVE modalities. RESULTS: Some TVE-derived variables indirectly reflected the atrial electrical activation that follows the known activation process as revealed by invasive electrophysiology. Regionally, the atrium shows an upward movement of its walls at the region near the atrio-ventricular ring with a reduction of this movement towards the upper levels of the atrial walls. The atrial mechanical function as assessed by several TVE-derived indices was quite similar in all left atrium (LA) walls. However, all such indices were higher in the right (RA) than the LA. There were no correlations between the 2-D- and TVE-derived variables expressing atrial mechanical function. Values of measurement error and repeatability were good for atrial mechanical function, but only acceptable for atrial electrical function. CONCLUSION: TVE may provide a simple, easy to obtain, reproducible, repeatable and potentially clinically useful tool for quantifying atrial electromechanical function
    corecore