169 research outputs found

    Observation of negative differential conductance in a reverse-biased Ni/Ge Schottky diode

    No full text
    We report the experimental observation of negative differential conductance in a Ni/Ge Schottky diode. With the aid of theoretical models and numerical simulation we show that, at reverse bias, electons tunnel into the high electric field of the depletion region. This scatters the electrons into the upper valley of the Ge conduction band, which has a lower mobility. The observed negative differential conductance is hence attributed to the transferred-electron effect. This shows that Schottky contacts can be used to create hot electrons for transferred-electron devices

    Orientation and symmetry control of inverse sphere magnetic nanoarrays by guided self-assembly

    No full text
    Inverse sphere shaped Ni arrays were fabricated by electrodeposition on Si through the guided self-assembly of polystyrene latex spheres in Si/SiO2 patterns. It is shown that the size commensurability of the etched tracks is critical for the long range ordering of the spheres. Moreover, noncommensurate guiding results in the reproducible periodic triangular distortion of the close packed self-assembly. Magnetoresistance measurements on the Ni arrays were performed showing room temperature anisotropic magnetoresistance of 0.85%. These results are promising for self-assembled patterned storage media and magnetoresistance devices

    A phantom study for the comparison of different brands of computed tomography scanners and software packages for endovascular aneurysm repair sizing and planning

    Get PDF
    Objectives: Correct sizing of endoprostheses used for the treatment of abdominal aortic aneurysms is important to prevent endoleaks and migration. Sizing requires several steps and each step introduces a possible sizing error. The goal of this study was to investigate the magnitude of these errors compared to the golden standard: a vessel phantom. This study focuses on the errors in sizing with three different brands of computed tomography angiography scanners in combination with three reconstruction software packages. Methods: Three phantoms with a different diameter, altitude and azimuth were scanned with three computed tomography scanners: Toshiba Aquilion 64-slice, Philips Brilliance iCT 256-slice and Siemens Somatom Sensation 64-slice. The phantom diameters were determined in the stretched view after central lumen line reconstruction by three observers using Simbionix PROcedure Rehearsal Studio, 3mensio and TeraRecon planning software. The observers, all novices in sizing endoprostheses using planning software, measured 108 slices each. Two senior vascular surgeons set the tolerated error margin of sizing on ±1.0?mm. Results: In total, 11.3% of the measurements (73/648) were outside the set margins of ±1.0 mm from the phantom diameter, with significant differences between the scanner types (14.8%, 12.1%, 6.9% for the Siemens scanner, Philips scanner and Toshiba scanner, respectively, p-value?=?0.032), but not between the software packages (8.3%, 11.1%, 14.4%, p-value?=?0.141) or the observers (10.6%, 9.7%, 13.4%, p-value?=?0.448). Conclusions: It can be concluded that the errors in sizing were independent of the used software packages, but the phantoms scanned with Siemens scanner were significantly more measured incorrectly than the phantoms scanned with the Toshiba scanner. Consequently, awareness on the type of computed tomography scanner and computed tomography scanner setting is necessary, especially in complex abdominal aortic aneurysms sizing for fenestrated or branched endovascular aneurysm repair if appropriate the sizing is of upmost importance

    The Influence of Positioning of the Nellix Endovascular Aneurysm Sealing System on Suprarenal and Renal Flow: An In Vitro Study

    Get PDF
    Purpose: To examine the influence of device positioning and infrarenal neck diameter on flow patterns in the Nellix endovascular aneurysm sealing (EVAS) system. Methods: The transition of the aortic flow lumen into two 10-mm-diameter stents after EVAS creates a mismatched area. Flow recirculation may affect local wall shear stress (WSS) profiles and residence time associated with atherosclerosis and thrombosis. To examine these issues, 7 abdominal aortic aneurysm flow phantoms were created, including 3 unstented controls and 3 stented models with infrarenal neck diameters of 24, 28, and 32 mm. Stents were positioned within the instructions for use (IFU). Another 28-mm model was created to evaluate lower positioning of the stents outside the IFU (28-mm LP). Flow was visualized using optical particle imaging velocimetry (PIV) and quantified by time-averaged WSS (TAWSS), oscillatory shear index (OSI), and relative residence time (RRT) in the aorta at the anteroposterior (AP) midplane, lateral midplane, and renal artery AP midplane levels. Results: Flow in the aorta AP midplane was similar in all models. Vortices were observed in the stented models in the lateral midplane near the anterior and posterior walls. In the 32-mm IFU and 28-mm LP models, a steady state of vortices appeared, with varying location during a cycle. In all models, a low TAWSS

    Haemodynamics in Different Flow Lumen Configurations of Customised Aortic Repair for Infrarenal Aortic Aneurysms

    Get PDF
    Objective: Customised aortic repair (CAR) is a new and minimally invasive technique for the endovascular treatment of abdominal aortic aneurysms (AAAs). The aneurysm is completely sealed with a non-contained, non-cross linked polymer, while a new flow lumen is created with balloons. For CAR, the haemodynamically most favourable balloon and flow lumen configuration has not been established before; therefore, four flow parameters were assessed in an in vitro model. Methods: Three in vitro balloon configurations were implanted in an in vitro AAA model; a configuration with crossing balloons (CC) and two parallel configurations (PC1 and PC2). These three models were consecutively placed in a flow system that mimics physiological flow conditions. Laser particle imaging velocimetry (PIV) was used to resolve spatial and temporal flow patterns during the cardiac cycle. In house built algorithms were used to analyse the PIV data for the computing of (i) flow velocity; (ii) vorticity; (iii) wall shear stress (WSS); and (iv) time averaged wall shear stress (TAWSS). Results: Suprarenal flow patterns were similar in all models. The CC showed a higher infrarenal velocity than PC1 and PC2 (38 cm/s vs. 23 cm/s vs. 23 cm/s), and a higher vorticity at the crossing of the lumens (CC: 337/s; PC1 127/s; PC2: 112/s). The lowest vorticity was observed in PC2, especially in the infrarenal neck (CC: 200/s; PC1 164/s; PC2: 98/s). Although WSS and TAWSS varied between configurations, values were the within non-pathological range. Conclusion: The flow lumens created by three balloon configurations used in an in vitro model of CAR have been studied, and resulted in different haemodynamics. The differences in velocity and lower vorticity, especially at the crossing section of the two balloons, showed that PC2 has favourable haemodynamics compared with the CC and PC1. Future research will be focused on the clinical applicability of CAR based on the PC2 design

    Large-Area Electrodeposition of Few-Layer MoS2 on Graphene for 2D Material Heterostructures

    Get PDF
    Heterostructures involving two-dimensional (2D) transition metal dichalcogenides and other materials such as graphene have a strong potential to be the fundamental building block of many electronic and opto-electronic applications. The integration and scalable fabrication of such heterostructures is of essence in unleashing the potential of these materials in new technologies. For the first time, we demonstrate the growth of few-layer MoS2 films on graphene via non-aqueous electrodeposition. Through methods such as scanning and transmission electron microscopy, atomic force microscopy, Raman spectroscopy, energy and wavelength dispersive X-ray spectroscopies and X-ray photoelectron spectroscopy, we show that this deposition method can produce large-area MoS2 films with high quality and uniformity over graphene. We reveal the potential of these heterostructures by measuring the photo-induced current through the film. These results pave the way towards developing the electrodeposition method for the large-scale growth of heterostructures consisting of varying 2D materials for many applications.Comment: 11 pages and 6 figure

    Somatostatin analogues for the prevention of pancreatic fistula after open pancreatoduodenectomy:A nationwide analysis

    Get PDF
    BACKGROUND: Somatostatin analogues (SA) are currently used to prevent postoperative pancreatic fistula (POPF) development. However, its use is controversial. This study investigated the effect of different SA protocols on the incidence of POPF after pancreatoduodenectomy in a nationwide population.METHODS: All patients undergoing elective open pancreatoduodenectomy were included from the Dutch Pancreatic Cancer Audit (2014-2017). Patients were divided into six groups: no SA, octreotide, lanreotide, pasireotide, octreotide only in high-risk (HR) patients and lanreotide only in HR patients. Primary endpoint was POPF grade B/C. The updated alternative Fistula Risk Score was used to compare POPF rates across various risk scenarios.RESULTS: 1992 patients were included. Overall POPF rate was 13.1%. Lanreotide (10.0%), octreotide-HR (9.4%) and no protocol (12.7%) POPF rates were lower compared to the other protocols (varying from 15.1 to 19.1%, p = 0.001) in crude analysis. Sub-analysis in patients with HR of POPF showed a significantly lower rate of POPF when treated with lanreotide (10.0%) compared to no protocol, octreotide and pasireotide protocol (21.6-26.9%, p = 0.006). Octreotide-HR and lanreotide-HR protocol POPF rates were comparable to lanreotide protocol, however not significantly different from the other protocols. Multivariable regression analysis demonstrated lanreotide protocol to be positively associated with a low odds-ratio (OR) for POPF (OR 0.387, 95% CI 0.180-0.834, p = 0.015). In-hospital mortality rates were not affected.CONCLUSION: Use of lanreotide in all patients undergoing pancreatoduodenectomy has a potential protective effect on POPF development. Protocols for HR patients only might be favorable too. However, future studies are warranted to confirm these findings.</p

    Feasibility and effectiveness of trifluridine/tipiracil in metastatic colorectal cancer: real-life data from The Netherlands

    Get PDF
    Background: The RECOURSE trial showed clinical efficacy for trifluridine/tipiracil for refractory metastatic colorectal cancer patients. We assessed the feasibility and effectiveness of trifluridine/tipiracil in daily clinical practice in The Netherlands. Methods: Medical records of patients from 17 centers treated in the trifluridine/tipiracil compassionate use program were reviewed and checked for RECOURSE eligibility criteria. Baseline characteristics, safety, and survival times were compared, and prespecified baseline characteristics were tested in multivariate analyses for prognostic significance on overall survival (OS). Results: A total of 136 patients with a median age of 62 years were analyzed. Forty-three patients (32%) did not meet the RECOURSE eligibility criteria for not having received all prior standard treatments (n = 35, 26%) and/or ECOG performance status (PS) 2 (n = 12, 9%). The most common grade ≥3 toxicities were neutropenia (n = 44, 32%), leukopenia (n = 8, 6%), anemia (n = 7, 5%), and fatigue (n = 7, 5%). Median progression-free survival (PFS) and median OS were 2.1 (95% CI, 1.8–2.3) and 5.4 months (95% CI, 4.0–6.9), respectively. Patients with ECOG PS 2 had a worse median OS (3.2 months) compared to patients with ECOG PS 0–1 (5.9 months). ECOG PS, KRAS-mutation status, white blood cell count, serum lactate dehydrogenase, and alkaline phosphatase were prognostic factors for OS. Conclusions: Our data show that treatment with trifluridine/tipiracil in daily clinical practice is feasible and safe. Differences in patient characteristics between our population and the RECOURSE study population should be taken into account in the interpretation of survival data. Our results argue against the use of trifluridine/tipiracil in patients with ECOG PS 2. Funding: Johannes J.M. Kwakman received an unrestricted research grant from Servier
    corecore