126 research outputs found

    Use of rod compactors for high voltage overhead power lines magnetic field mitigation

    Get PDF
    In the last decades, strengthening the high voltage transmission system through the installation of new overhead power lines has become critical, especially in highly developed areas. Present laws concerning the human exposure to electric and magnetic fields introduce constraints to be considered in both new line construction and existing systems. In the paper, a technique for passive magnetic field mitigation in areas close to overhead power lines is introduced, fully modelled and discussed through a parametric analysis. The investigated solution, which basically consists in approaching line conductors along the span making use of rod insulators, is applicable on both existing and under-design overhead lines as an alternative to other mitigating actions. Making use of a 3-dimensional representation, the procedure computes both positions of phase conductors and forces acting on insulators, towers, conductors and compactors, with the aim of evaluating the additional mechanical stress introduced by the compactors. Finally, a real case study is reported to demonstrate and quantify the benefits in terms of ground magnetic field reduction achievable by applying the proposed solution, in comparison to a traditional configuration. Furthermore, using compactors to passively reduce the magnetic field is simple to be applied, minimally invasive and quite inexpensive as regards to alternative mitigating actions

    Effects of energy storage systems grid code requirements on interface protection performances in low voltage networks

    Get PDF
    The ever-growing penetration of local generation in distribution networks and the large diffusion of energy storage systems (ESSs) foreseen in the near future are bound to affect the effectiveness of interface protection systems (IPSs), with negative impact on the safety of medium voltage (MV) and low voltage (LV) systems. With the scope of preserving the main network stability, international and national grid connection codes have been updated recently. Consequently, distributed generators (DGs) and storage units are increasingly called to provide stabilizing functions according to local voltage and frequency. This can be achieved by suitably controlling the electronic power converters interfacing small-scale generators and storage units to the network. The paper focuses on the regulating functions required to storage units by grid codes currently in force in the European area. Indeed, even if such regulating actions would enable local units in participating to network stability under normal steady-state operating conditions, it is shown through dynamic simulations that they may increase the risk of unintentional islanding occurrence. This means that dangerous operating conditions may arise in LV networks in case dispersed generators and storage systems are present, even if all the end-users are compliant with currently applied connection standards

    Generalised transformer modelling for power flow calculation in multi-phase unbalanced networks

    Get PDF
    Low voltage systems are unbalanced networks where a significant share of the users is single-phase connected, so a multi-phase system needs to be considered in order to assess the mutual influence of the different phases. The presence of single-phase unevenly distributed users, leads to unbalances in the power flow on the three phases. This issue is emphasised considering the presence of local single-phase generators. This study presents a generalised method for transformers modelling in any multi-conductor grid representation in order to allow the analysis on unbalanced networks such as low-voltage distribution systems. The method, based on an incidence matrix approach, is proposed to represent any network object involving mutual connections among the phases, once the impedances for each single-phase equivalent circuit are known. Some application examples validate the approach and illustrate how to numerically realise the model

    Voltage Management in Unbalanced Low Voltage Networks Using a Decoupled Phase-Tap-Changer Transformer

    Get PDF
    The paper studies a medium voltage-low voltage transformer with a decoupled on load tap changer capability on each phase. The overall objective is the evaluation of the potential benefits on a low voltage network of such possibility. A realistic Danish low voltage network is used for the analysis. The load profiles are characterized by using single phase measurement data on voltages, currents and active powers with a 10 minutes resolution. Different scenarios are considered: no tap action, Three-phase coordinated tap action, single phase discrete step and single phase continuous tap action. The effectiveness of the tapping capability is evaluated by comparing the Voltage Unbalance Factor and the voltage levels on the neutral cable

    Reactive Power Control for Smarter (Urban) Distribution Network Management With Increasing Integration of Renewable Prosumers

    Get PDF
    Smart cities need to deliver reliable electric energy while utilizing every renewable energy source available in a sustainable manner. Increasing renewable electricity capacity, through Distributed Generation (DG) such as small wind and PV generation, causes difficulties for the distribution network operator (DNO) in sustaining adequate and appropriate power quality across the network. The positive impacts provided by such energy sources can be undermined by voltage increases and voltage balance issues. To overcome these problems, urban distribution networks need to transform ideally into smarter energy networks that can deliver renewable electricity locally, predictably and in a controllable and optimized manner. The research presented here is based on electricity network simulation in an urban context. The main focus is the hosting capacity enhancement of distribution networks, while maintaining power quality, which is ultimately a pre-requisite for increasing prosumer engagement. In this regard, a test-bed representation of a 4-wire low-voltage section of distribution network in Dublin, Ireland is developed in DIgSILENT Power Factory. Several scenarios that consider increasing penetration of renewable prosumers in a smart electricity network context are presented. The results show that STATCOM, in the context of increasing DG integration, can provide continuous voltage support, by supplying or absorbing reactive power and thereby facilitating increased renewable DG contributions for a smarter, greener network

    Structural pattern of the western Las Cañadas caldera (Tenerife, Canary Islands) revealed by audiomagnetotellurics

    Get PDF
    The local and regional structural pattern of volcanic edifices strongly controls the space distribution of electrical resistivity. Here we report on the structural context of the western part of the Las Cañadas caldera of Tenerife (LCC) thought to have initiated the formation of the caldera. Using a new dataset of 11 audiomagnetotelluric tensors we emphasize the resistivity distribution of Ucanca caldera and propose a major revision of its extension. We find that Ucanca caldera has a limited westwards extent and that El Cedro sector is a depression margin of the caldera. According to the extent of hydrothermalized rocks at the base of the LCC wall and the distribution of Pico Teide - Pico Viejo vents, we constrain the location and size of Ucanca caldera. The interpretation of these results also constrains the extension of the Icod Valley and proposes a headwall located below the Pico Teide - Pico Viejo Comple

    Voltage Control for Unbalanced Low Voltage Grids Using a Decoupled-Phase On-Load Tap-Changer Transformer and Photovoltaic Inverters

    Get PDF
    This paper presents modeling and analysis of the potential benefits of joint actions of a MV/LV three-phase power distribution transformer with independent on-load tap-changer control on each phase and photovoltaic inverters provided with reactive power control capability, in terms of accommodating more renewable generations in the LV grid. The potential benefits are investigated in terms of voltage unbalance reduction and local voltage regulation. 24-hours root-mean-square dynamics simulation studies have been carried out with timestep of 1 second using 10-mins resolution consumption and production profiles. A totally passive real Danish low voltage distribution network is used for the grid topology as well as for the characterization of loads profiles, while the production ones are empirically defined under assumptions in scenarios with different level of photovoltaic penetration and grade of unbalance

    Centralized OPF in Unbalanced Multi-Phase Neutral Equipped Distribution Networks Hosting ZIP Loads

    Get PDF
    The Optimal Power Flow (OPF) model for low voltage active Distribution Networks (DNs), which are equipped with neutral conductors, requires an explicit representation of both phases and neutral conductors in its formulation to obtain complete information about the state variables related to these conductors. In this regard, a centralized OPF relaxation based on semi-definite programming is presented in this paper for neutral-equipped DNs hosting ZIP loads and neutral-ground impedance, and contain a significant level of unbalance. The major restriction in the development of an OPF model for these networks is the coupled power injection across the conductors which is successfully handled by deriving the explicit active and reactive power injections for each conductor through a network admittance matrix-based approach. The shortcomings of existing voltage magnitude-based technique for the modelling of ZIP loads are comprehensively reported and a novel complex voltage variable-based approach is proposed which successfully incorporates ZIP loads in the developed multi-phase OPF relaxation. For the handling of constant current load, a modelling approach based on the first-order-Taylor series is introduced as well. Furthermore, the impact of the application of Kron reduction approach on the global optimal solution of single- and multiple-point grounded DNs is discussed in detail. Three metrics, eigenvalue ratio, power mismatch and cumulative normalized constraint violation, are utilized to evaluate the exactness of proposed relaxation. Simulations, carried out on several medium and low voltage DNs, show that the proposed relaxation is numerically exact under several combinations of ZIP load parameters and a reasonable range of grounding impedance value for both time-varying and extreme system loading scenarios irrespective of the degree of unbalance in a network

    Distinct but interchangeable subpopulations of colorectal cancer cells with different growth fates and drug sensitivity

    Get PDF
    大腸がん細胞の増殖運命の違いと薬剤感受性 --その柔軟性を決めるメカニズム--. 京都大学プレスリリース. 2023-01-20.Dynamic changes in cell properties lead to intratumor heterogeneity; however, the mechanisms of nongenetic cellular plasticity remain elusive. When the fate of each cell from colorectal cancer organoids was tracked through a clonogenic growth assay, the cells showed a wide range of growth ability even within the clonal organoids, consisting of distinct subpopulations; the cells generating large spheroids and the cells generating small spheroids. The cells from the small spheroids generated only small spheroids (S-pattern), while the cells from the large spheroids generated both small and large spheroids (D-pattern), both of which were tumorigenic. Transition from the S-pattern to the D-pattern occurred by various extrinsic triggers, in which Notch signaling and Musashi-1 played a key role. The S-pattern spheroids were resistant to chemotherapy and transited to the D-pattern upon drug treatment through Notch signaling. As the transition is linked to the drug resistance, it can be a therapeutic target
    corecore