8 research outputs found
Organ Shape Sensing using Pneumatically Attachable Flexible Rails in Robotic-Assisted Laparoscopic Surgery
In robotic-assisted partial nephrectomy, surgeons remove a part of a kidney
often due to the presence of a mass. A drop-in ultrasound probe paired to a
surgical robot is deployed to execute multiple swipes over the kidney surface
to localise the mass and define the margins of resection. This sub-task is
challenging and must be performed by a highly skilled surgeon. Automating this
sub-task may reduce cognitive load for the surgeon and improve patient
outcomes. The overall goal of this work is to autonomously move the ultrasound
probe on the surface of the kidney taking advantage of the use of the
Pneumatically Attachable Flexible (PAF) rail system, a soft robotic device used
for organ scanning and repositioning. First, we integrate a shape-sensing
optical fibre into the PAF rail system to evaluate the curvature of target
organs in robotic-assisted laparoscopic surgery. Then, we investigate the
impact of the stiffness of the material of the PAF rail on the curvature
sensing accuracy, considering that soft targets are present in the surgical
field. Finally, we use shape sensing to plan the trajectory of the da Vinci
surgical robot paired with a drop-in ultrasound probe and autonomously generate
an Ultrasound scan of a kidney phantom.Comment: 9 pages, 11 figure
LowâField Actuating Magnetic Elastomer Membranes Characterized using FibreâOptic Interferometry
Smart robotic devices remotely powered by magnetic field have emerged as versatile tools for wide biomedical applications. Soft magnetic elastomer (ME) composite membranes with high flexibility and responsiveness are frequently incorporated to enable local actuation for wireless sensing or cargo delivery. However, the fabrication of thin ME membranes with good control in geometry and uniformity remains challenging, as well as the optimization of their actuating performances under low fields (milliâTesla). In this work, the development of ME membranes comprising of lowâcost magnetic powder and highly soft elastomer through a simple templateâassisted doctor blading approach, is reported. The fabricated ME membranes are controllable in size (up to centimetreâscale), thickness (tens of microns) and high particle loading (up to 70 wt.%). Conflicting tradeâoff effects of particle concentration upon magnetic responsiveness and mechanical stiffness are investigated and found to be balanced off as it exceeds 60 wt.%. A highly sensitive fibreâoptic interferometric sensing system and a customized fibreâferruleâmembrane probe are first proposed to enable dynamic actuation and realâtime displacement characterization. Freeâstanding ME membranes are magnetically excited under low field down to 2 mT, and optically monitored with nanometer accuracy. The fast and consistent responses of ME membranes showcase their promising biomedical applications in nanoscale actuation and sensing
Lowâfield actuating magnetic elastomer membranes characterized using fibreâoptic interferometry
Smart robotic devices remotely powered by magnetic field have emerged as versatile tools for wide biomedical applications. Soft magnetic elastomer (ME) composite membranes with high flexibility and responsiveness are frequently incorporated to enable local actuation for wireless sensing or cargo delivery. However, the fabrication of thin ME membranes with good control in geometry and uniformity remains challenging, as well as the optimization of their actuating performances under low fields (milliâTesla). In this work, the development of ME membranes comprising of lowâcost magnetic powder and highly soft elastomer through a simple templateâassisted doctor blading approach, is reported. The fabricated ME membranes are controllable in size (up to centimetreâscale), thickness (tens of microns) and high particle loading (up to 70 wt.%). Conflicting tradeâoff effects of particle concentration upon magnetic responsiveness and mechanical stiffness are investigated and found to be balanced off as it exceeds 60 wt.%. A highly sensitive fibreâoptic interferometric sensing system and a customized fibreâferruleâmembrane probe are first proposed to enable dynamic actuation and realâtime displacement characterization. Freeâstanding ME membranes are magnetically excited under low field down to 2 mT, and optically monitored with nanometer accuracy. The fast and consistent responses of ME membranes showcase their promising biomedical applications in nanoscale actuation and sensing
Dynamic Characterisation of Fibre-Optic Temperature Sensors for Physiological Monitoring
Fast, miniature temperature sensors are required for various biomedical applications. Fibre-optics are particularly suited to minimally invasive procedures, and many types of fibre-optic temperature sensors have been demonstrated. In applications where rapidly varying temperatures are present, a fast and well-known response time is important; however, in many cases, the dynamic behaviour of the sensor is not well-known. In this article, we investigate the dynamic response of a polymer-based interferometric temperature sensor, using both an experimental technique employing optical heating with a pulsed laser, and a computational heat transfer model based on the finite element method. Our results show that the sensor has a time constant on the order of milliseconds and a −6 dB bandwidth of up to 178 Hz, indicating its suitability for applications such as flow measurement by thermal techniques, photothermal spectroscopy, and monitoring of thermal treatments
Extending thrombolysis to 4·5â9 h and wake-up stroke using perfusion imaging: a systematic review and meta-analysis of individual patient data
Background:
Stroke thrombolysis with alteplase is currently recommended 0â4·5 h after stroke onset. We aimed to determine whether perfusion imaging can identify patients with salvageable brain tissue with symptoms 4·5 h or more from stroke onset or with symptoms on waking who might benefit from thrombolysis.
Methods:
In this systematic review and meta-analysis of individual patient data, we searched PubMed for randomised trials published in English between Jan 1, 2006, and March 1, 2019. We also reviewed the reference list of a previous systematic review of thrombolysis and searched ClinicalTrials.gov for interventional studies of ischaemic stroke. Studies of alteplase versus placebo in patients (aged â„18 years) with ischaemic stroke treated more than 4·5 h after onset, or with wake-up stroke, who were imaged with perfusion-diffusion MRI or CT perfusion were eligible for inclusion. The primary outcome was excellent functional outcome (modified Rankin Scale [mRS] score 0â1) at 3 months, adjusted for baseline age and clinical severity. Safety outcomes were death and symptomatic intracerebral haemorrhage. We calculated odds ratios, adjusted for baseline age and National Institutes of Health Stroke Scale score, using mixed-effects logistic regression models. This study is registered with PROSPERO, number CRD42019128036.
Findings:
We identified three trials that met eligibility criteria: EXTEND, ECASS4-EXTEND, and EPITHET. Of the 414 patients included in the three trials, 213 (51%) were assigned to receive alteplase and 201 (49%) were assigned to receive placebo. Overall, 211 patients in the alteplase group and 199 patients in the placebo group had mRS assessment data at 3 months and thus were included in the analysis of the primary outcome. 76 (36%) of 211 patients in the alteplase group and 58 (29%) of 199 patients in the placebo group had achieved excellent functional outcome at 3 months (adjusted odds ratio [OR] 1·86, 95% CI 1·15â2·99, p=0·011). Symptomatic intracerebral haemorrhage was more common in the alteplase group than the placebo group (ten [5%] of 213 patients vs one [<1%] of 201 patients in the placebo group; adjusted OR 9·7, 95% CI 1·23â76·55, p=0·031). 29 (14%) of 213 patients in the alteplase group and 18 (9%) of 201 patients in the placebo group died (adjusted OR 1·55, 0·81â2·96, p=0·66).
Interpretation:
Patients with ischaemic stroke 4·5â9 h from stroke onset or wake-up stroke with salvageable brain tissue who were treated with alteplase achieved better functional outcomes than did patients given placebo. The rate of symptomatic intracerebral haemorrhage was higher with alteplase, but this increase did not negate the overall net benefit of thrombolysis
Effect of general anaesthesia on functional outcome in patients with anterior circulation ischaemic stroke having endovascular thrombectomy versus standard care: a meta-analysis of individual patient data
Background:
General anaesthesia (GA) during endovascular thrombectomy has been associated with worse patient outcomes in observational studies compared with patients treated without GA. We assessed functional outcome in ischaemic stroke patients with large vessel anterior circulation occlusion undergoing endovascular thrombectomy under GA, versus thrombectomy not under GA (with or without sedation) versus standard care (ie, no thrombectomy), stratified by the use of GA versus standard care.
Methods:
For this meta-analysis, patient-level data were pooled from all patients included in randomised trials in PuMed published between Jan 1, 2010, and May 31, 2017, that compared endovascular thrombectomy predominantly done with stent retrievers with standard care in anterior circulation ischaemic stroke patients (HERMES Collaboration). The primary outcome was functional outcome assessed by ordinal analysis of the modified Rankin scale (mRS) at 90 days in the GA and non-GA subgroups of patients treated with endovascular therapy versus those patients treated with standard care, adjusted for baseline prognostic variables. To account for between-trial variance we used mixed-effects modelling with a random effect for trials incorporated in all models. Bias was assessed using the Cochrane method. The meta-analysis was prospectively designed, but not registered.
Findings:
Seven trials were identified by our search; of 1764 patients included in these trials, 871 were allocated to endovascular thrombectomy and 893 were assigned standard care. After exclusion of 74 patients (72 did not undergo the procedure and two had missing data on anaesthetic strategy), 236 (30%) of 797 patients who had endovascular procedures were treated under GA. At baseline, patients receiving GA were younger and had a shorter delay between stroke onset and randomisation but they had similar pre-treatment clinical severity compared with patients who did not have GA. Endovascular thrombectomy improved functional outcome at 3 months both in patients who had GA (adjusted common odds ratio (cOR) 1·52, 95% CI 1·09â2·11, p=0·014) and in those who did not have GA (adjusted cOR 2·33, 95% CI 1·75â3·10, p<0·0001) versus standard care. However, outcomes were significantly better for patients who did not receive GA versus those who received GA (covariate-adjusted cOR 1·53, 95% CI 1·14â2·04, p=0·0044). The risk of bias and variability between studies was assessed to be low.
Interpretation:
Worse outcomes after endovascular thrombectomy were associated with GA, after adjustment for baseline prognostic variables. These data support avoidance of GA whenever possible. The procedure did, however, remain effective versus standard care in patients treated under GA, indicating that treatment should not be withheld in those who require anaesthesia for medical reasons
Intravenous alteplase for stroke with unknown time of onset guided by advanced imaging: systematic review and meta-analysis of individual patient data
Background: Patients who have had a stroke with unknown time of onset have been previously excluded from thrombolysis. We aimed to establish whether intravenous alteplase is safe and effective in such patients when salvageable tissue has been identified with imaging biomarkers. Methods: We did a systematic review and meta-analysis of individual patient data for trials published before Sept 21, 2020. Randomised trials of intravenous alteplase versus standard of care or placebo in adults with stroke with unknown time of onset with perfusion-diffusion MRI, perfusion CT, or MRI with diffusion weighted imaging-fluid attenuated inversion recovery (DWI-FLAIR) mismatch were eligible. The primary outcome was favourable functional outcome (score of 0â1 on the modified Rankin Scale [mRS]) at 90 days indicating no disability using an unconditional mixed-effect logistic-regression model fitted to estimate the treatment effect. Secondary outcomes were mRS shift towards a better functional outcome and independent outcome (mRS 0â2) at 90 days. Safety outcomes included death, severe disability or death (mRS score 4â6), and symptomatic intracranial haemorrhage. This study is registered with PROSPERO, CRD42020166903. Findings: Of 249 identified abstracts, four trials met our eligibility criteria for inclusion: WAKE-UP, EXTEND, THAWS, and ECASS-4. The four trials provided individual patient data for 843 individuals, of whom 429 (51%) were assigned to alteplase and 414 (49%) to placebo or standard care. A favourable outcome occurred in 199 (47%) of 420 patients with alteplase and in 160 (39%) of 409 patients among controls (adjusted odds ratio [OR] 1·49 [95% CI 1·10â2·03]; p=0·011), with low heterogeneity across studies (I 2=27%). Alteplase was associated with a significant shift towards better functional outcome (adjusted common OR 1·38 [95% CI 1·05â1·80]; p=0·019), and a higher odds of independent outcome (adjusted OR 1·50 [1·06â2·12]; p=0·022). In the alteplase group, 90 (21%) patients were severely disabled or died (mRS score 4â6), compared with 102 (25%) patients in the control group (adjusted OR 0·76 [0·52â1·11]; p=0·15). 27 (6%) patients died in the alteplase group and 14 (3%) patients died among controls (adjusted OR 2·06 [1·03â4·09]; p=0·040). The prevalence of symptomatic intracranial haemorrhage was higher in the alteplase group than among controls (11 [3%] vs two [<1%], adjusted OR 5·58 [1·22â25·50]; p=0·024). Interpretation: In patients who have had a stroke with unknown time of onset with a DWI-FLAIR or perfusion mismatch, intravenous alteplase resulted in better functional outcome at 90 days than placebo or standard care. A net benefit was observed for all functional outcomes despite an increased risk of symptomatic intracranial haemorrhage. Although there were more deaths with alteplase than placebo, there were fewer cases of severe disability or death. Funding: None