197 research outputs found

    Development of a low-maintenance measurement approach to continuously estimate methane emissions: a case study

    Get PDF
    The chemical breakdown of organic matter in landfills represents a significant source of methane gas (CH4). Current estimates suggest that landfills are responsible for between 3% and 19% of global anthropogenic emissions. The net CH4 emissions resulting from biogeochemical processes and their modulation by microbes in landfills are poorly constrained by imprecise knowledge of environmental constraints. The uncertainty in absolute CH4 emissions from landfills is therefore considerable. This study investigates a new method to estimate the temporal variability of CH4 emissions using meteorological and CH4 concentration measurements downwind of a landfill site in Suffolk, UK from July to September 2014, taking advantage of the statistics that such a measurement approach offers versus shorter-term, but more complex and instantaneously accurate, flux snapshots. Methane emissions were calculated from CH4 concentrations measured 700 m from the perimeter of the landfill with observed concentrations ranging from background to 46.4 ppm. Using an atmospheric dispersion model, we estimate a mean emission flux of 709 μg m−2 s−1 over this period, with a maximum value of 6.21 mg m−2 s−1, reflecting the wide natural variability in biogeochemical and other environmental controls on net site emission. The emissions calculated suggest that meteorological conditions have an influence on the magnitude of CH4 emissions. We also investigate the factors responsible for the large variability observed in the estimated CH4 emissions, and suggest that the largest component arises from uncertainty in the spatial distribution of CH4 emissions within the landfill area. The results determined using the low-maintenance approach discussed in this paper suggest that a network of cheaper, less precise CH4 sensors could be used to measure a continuous CH4 emission time series from a landfill site, something that is not practical using far-field approaches such as tracer release methods. Even though there are limitations to the approach described here, this easy, low-maintenance, low-cost method could be used by landfill operators to estimate time-averaged CH4 emissions and their impact downwind by simultaneously monitoring plume advection and CH4 concentrations

    Intraluminal measurement of papillary duct urine pH, in vivo: a pilot study in the swine kidney

    Get PDF
    We describe the in vivo use of an optic-chemo microsensor to measure intraluminal papillary duct urine pH in a large mammal. Fiber-optic pH microsensors have a tip diameter of 140-µm that allows insertion into papillary Bellini ducts to measure tubule urine proton concentration. Anesthetized adult pigs underwent percutaneous nephrolithotomy to access the lower pole of the urinary collecting system. A flexible nephroscope was advanced towards an upper pole papilla with the fiber-optic microsensor contained within the working channel. The microsensor was then carefully inserted into Bellini ducts to measure tubule urine pH in real time. We successfully recorded tubule urine pH values in five papillary ducts from three pigs (1 farm pig and 2 metabolic syndrome Ossabaw pigs). Our results demonstrate that optical microsensor technology can be used to measure intraluminal urine pH in real time in a living large mammal. This opens the possibility for application of this optical pH sensing technology in nephrolithiasis

    Mechanism by which shock wave lithotripsy can promote formation of human calcium phosphate stones

    Get PDF
    Human stone calcium phosphate (CaP) content correlates with higher urine CaP supersaturation (SS) and urine pH as well as with the number of shock wave lithotripsy (SWL) treatments. SWL does damage medullary collecting ducts and vasa recta, sites for urine pH regulation. We tested the hypothesis that SWL raises urine pH and therefore Cap SS, resulting in CaP nucleation and tubular plugging. The left kidney (T) of nine farm pigs was treated with SWL, and metabolic studies were performed using bilateral ureteral catheters for up to 70 days post-SWL. Some animals were given an NH4Cl load to sort out effects on urine pH of CD injury vs. increased HCO3 (-) delivery. Histopathological studies were performed at the end of the functional studies. The mean pH of the T kidneys exceeded that of the control (C) kidneys by 0.18 units in 14 experiments on 9 pigs. Increased HCO3 (-) delivery to CD is at least partly responsible for the pH difference because NH4Cl acidosis abolished it. The T kidneys excreted more Na, K, HCO3 (-), water, Ca, Mg, and Cl than C kidneys. A single nephron site that could produce losses of all of these is the thick ascending limb. Extensive injury was noted in medullary thick ascending limbs and collecting ducts. Linear bands showing nephron loss and fibrosis were found in the cortex and extended into the medulla. Thus SWL produces tubule cell injury easily observed histopathologically that leads to functional disturbances across a wide range of electrolyte metabolism including higher than control urine pH

    Atubular glomeruli in a rat model of polycystic kidney disease

    Get PDF
    Atubular glomeruli in a rat model of polycystic kidney disease.BackgroundAutosomal-dominant polycystic kidney disease (ADPKD) is associated with a progressive decline in glomerular filtration rate (GFR) that often leads to end-stage renal disease. The basis for this decline in GFR is poorly understood.MethodsGlomeruli in heterozygous Han:SPRD rats with ADPKD and their normal litter mates were studied by light microscopy, using serial sectioning techniques. The connections of the renal corpuscles to proximal tubules were classified as normal, atrophied, or absent (atubular glomerulus). Renal corpuscles also were examined by scanning electron microscopy. Single nephron glomerular blood flows were determined using microspheres.ResultsIn the kidneys of six-month-old rats with ADPKD, 50% of the glomeruli were atubular and another 26% were associated with atrophied neck segments; these glomeruli were most often smaller in size than normal. About 16% of the glomeruli were hypertrophied and had normal connections to proximal tubules. Sclerotic changes in cystic kidney glomeruli were usually mild or moderate, and belied the failure of glomerular function. Glomerular blood flow in the cystic kidneys averaged half of normal and was markedly heterogeneous; the majority of small glomeruli displayed very low blood flows and a few showed relatively high blood flows. Fewer glomerular abnormalities were found in rats treated for five months with potassium citrate in their drinking water.ConclusionsThe diminished GFR in the rat with ADPKD can be accounted for largely by the formation of atubular glomeruli. Compensatory glomerular hypertrophy also is present and may contribute to the progression of the renal disease

    Preliminary Report on Stone Breakage and Lesion Size Produced by a New Extracorporeal Electrohydraulic (Sparker Array) Discharge Device

    Get PDF
    Objective To determine if an innovative extracorporeal electrohydraulic shock wave device (sparker array) can effectively fracture artificial stones in vitro and in vivo, and if sparker array treatment produces a renal lesion in our pig model of lithotripsy injury. Results of these experiments will be used to help evaluate the suitability of this device as a clinical lithotripter. Methods Utracal-30 artificial stones were placed in a holder at the focus of the sparker array and treated with 600 shock waves (21.6 kV, 60 shocks/min). Stone fragments were collected, dried and weighed to determine stone breakage. In vivo stone breakage entailed implanting stones into pigs. These stones were treated with 600 or 1200 shock waves and the fragments collected for analysis. Lesion analysis consisted of treating the left kidney of pigs with 1200 or 2400 shock waves and quantitating the hemorrhagic lesion. Results In vitro, 71±2% of each artificial stone was fractured to < 2 mm in size. In vivo stone breakage averaged 63%. Renal injury analysis revealed that only 1 out of 7 kidneys showed evidence of hemorrhagic injury in the treated area. Conclusions The sparker array consistently comminuted artificial stones demonstrating its ability to fracture stones like other lithotripters. Also, the sparker array caused little to no renal injury at the settings used in this study. These findings suggest further research is warranted to determine the potential of this device as a clinical lithotripter

    Effect of renal shock wave lithotripsy on the development of metabolic syndrome in a juvenile swine model: a pilot study

    Get PDF
    PURPOSE: We performed a pilot study to assess whether renal shock wave lithotripsy influences metabolic syndrome onset and severity. MATERIALS AND METHODS: Three-month-old juvenile female Ossabaw miniature pigs were treated with shock wave lithotripsy (2,000 shock waves at 24 kV with 120 shock waves per minute in 2) or sham shock wave lithotripsy (no shock waves in 2). Shock waves were targeted to the upper pole of the left kidney to model treatment that would also expose the pancreatic tail to shock waves. Pigs were then instrumented to directly measure arterial blood pressure via an implanted radiotelemetry device. They later received a hypercaloric atherogenic diet for about 7 months. Metabolic syndrome development was assessed by the intravenous glucose tolerance test. RESULTS: Metabolic syndrome progression and severity were similar in the sham treated and lithotripsy groups. The only exception arterial blood pressure, which remained relatively constant in sham treated pigs but began to increase at about 2 months towards hypertensive levels in lithotripsy treated pigs. Metabolic data on the 2 groups were pooled to provide a more complete assessment of metabolic syndrome development and progression in this juvenile pig model. The intravenous glucose tolerance test revealed substantial insulin resistance with impaired glucose tolerance within 2 months on the hypercaloric atherogenic diet with signs of further metabolic impairment at 7 months. CONCLUSIONS: These preliminary results suggest that renal shock wave lithotripsy is not a risk factor for worsening glucose tolerance or diabetes mellitus onset. However, it appears to be a risk factor for early onset hypertension in metabolic syndrome

    Evaluation of an experimental electrohydraulic discharge device for extracorporeal shock wave lithotripsy: Pressure field of sparker array

    Get PDF
    In this paper, an extracorporeal shock wave source composed of small ellipsoidal sparker units is described. The sparker units were arranged in an array designed to produce a coherent shock wave of sufficient strength to fracture kidney stones. The objective of this paper was to measure the acoustical output of this array of 18 individual sparker units and compare this array to commercial lithotripters. Representative waveforms acquired with a fiber-optic probe hydrophone at the geometric focus of the sparker array indicated that the sparker array produces a shock wave (P+ ∼40-47 MPa, P- ∼2.5-5.0 MPa) similar to shock waves produced by a Dornier HM-3 or Dornier Compact S. The sparker array's pressure field map also appeared similar to the measurements from a HM-3 and Compact S. Compared to the HM-3, the electrohydraulic technology of the sparker array produced a more consistent SW pulse (shot-to-shot positive pressure value standard deviation of ±4.7 MPa vs ±3.3 MPa)

    Composition of the L5 Mars Trojans: Neighbors, not Siblings

    Full text link
    Mars is the only terrestrial planet known to have Tro jan (co-orbiting) asteroids, with a confirmed population of at least 4 objects. The origin of these objects is not known; while several have orbits that are stable on solar-system timescales, work by Rivkin et al. (2003) showed they have compositions that suggest separate origins from one another. We have obtained infrared (0.8-2.5 micron) spectroscopy of the two largest L5 Mars Tro jans, and confirm and extend the results of Rivkin et al. (2003). We suggest that the differentiated angrite meteorites are good spectral analogs for 5261 Eureka, the largest Mars Trojan. Meteorite analogs for 101429 1998 VF31 are more varied and include primitive achondrites and mesosiderites.Comment: 14 manuscript pages, 1 table, 6 figures. To be published in Icarus. See companion paper 0709.1921 by Trilling et a
    • …
    corecore