178 research outputs found

    First-time patellar dislocation with resultant habitual dislocation two years later, which was not demonstrated on plain X-rays halfway: a case report

    Get PDF
    We present an instructive case of habitual left patellar dislocation in which the patella had appeared odd due to lateral tilt relative to contralateral side, but had been radiologically confirmed to be on the trochlea at 1 year prior to the referral. An 11-year-old girl presented to our hospital 2 years after the left patella had dislocated with a 'giving way' when cutting to the left. Our physical and radiological examinations confirmed that the left patella was laterally tilted in the patellar groove with the knee in extension but was dislocated in flexion beyond 45°. In spite of these findings, she had been untreated at the previous hospital since all plain X-rays, including a skyline patellar view, had failed to demonstrate the dislocation. Consequently, in addition to reconstruction of medial patellofemoral ligament, she had to undergo a lateral retinacular release, which might have been unnecessary if treated earlier. This case illustrates that first-time patellar dislocation can gradually lead to habitual dislocation subsequently, and that cautious physical examinations in regard to patella tracking are essential since radiological examinations do not always reveal the pathophysiology of patellar instability

    Improvements in survival of the uncemented Nottingham Total Shoulder prosthesis: a prospective comparative study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The uncemented Nottingham Total Shoulder Replacement prosthesis system (Nottingham TSR) was developed from the previous BioModular<sup>® </sup>shoulder prosthesis taking into consideration the causes of the initial implant's failure.</p> <p>We investigated the impact of changes in the design of Nottingham TSR prosthesis on its survivorship rate.</p> <p>Methods</p> <p>Survivorship analyses of three types of uncemented total shoulder arthroplasty prostheses (BioModular<sup>®</sup>, initial Nottingham TSR and current Nottingham TSR systems with 11, 8 and 4 year survivorship data respectively) were compared. All these prostheses were implanted for the treatment of disabling pain in the shoulder due to primary and secondary osteoarthritis or rheumatoid arthritis. Each type of the prosthesis studied was implanted in consecutive group of patients – 90 patients with BioModular<sup>® </sup>system, 103 with the initial Nottingham TSR and 34 patients with the current Nottingham TSR system.</p> <p>The comparison of the annual cumulative survivorship values in the compatible time range between the three groups was done according to the paired <it>t </it>test.</p> <p>Results</p> <p>The 8-year and 11-year survivorship rates for the initially used modified BioModular<sup>® </sup>uncemented prosthesis were relatively low (75.6% and 71.7% respectively) comparing to the reported survivorship of the conventional cemented implants. The 8-year survivorship for the uncemented Nottingham TSR prosthesis was significantly higher (81.8%), but still not in the desired range of above 90%, that is found in other cemented designs. Glenoid component loosening was the main factor of prosthesis failure in both prostheses and mainly occurred in the first 4 postoperative years. The 4-year survivorship of the currently re-designed Nottingham TSR prosthesis, with hydroxylapatite coating of the glenoid baseplate, was significantly higher, 93.1% as compared to 85.1% of the previous Nottingham TSR.</p> <p>Conclusion</p> <p>The initial Nottingham shoulder prosthesis showed significantly higher survivorship than the BioModular<sup>® </sup>uncemented prosthesis, but lower than expected. Subsequently re-designed Nottingham TSR system presented a high short term survivorship rate that encourages its ongoing use</p

    Risk factors for revision after shoulder arthroplasty: 1,825 shoulder arthroplasties from the Norwegian Arthroplasty Register

    Get PDF
    Background and purpose Previous studies on shoulder arthroplasty have usually described small patient populations, and few articles have addressed the survival of shoulder implants. We describe the results of shoulder replacement in the Norwegian population (of 4.7 million) during a 12-year period. Trends in the use of shoulder arthroplasty during the study period were also investigated

    Total Shoulder Arthroplasty

    Get PDF
    Shoulder arthroplasty has been the subject of marked advances over the last few years. Modern implants provide a wide range of options, including resurfacing of the humeral head, anatomic hemiarthroplasty, total shoulder arthroplasty, reverse shoulder arthroplasty and trauma-specific implants for fractures and nonunions. Most humeral components achieve successful long-term fixation without bone cement. Cemented all-polyethylene glenoid components remain the standard for anatomic total shoulder arthroplasty. The results of shoulder arthroplasty vary depending on the underlying diagnosis, the condition of the soft-tissues, and the type of reconstruction. Total shoulder arthroplasty seems to provide the best outcome for patients with osteoarthritis and inflammatory arthropathy. The outcome of hemiarthroplasty for proximal humerus fractures is somewhat unpredictable, though it seems to have improved with the use of fracture-specific designs, more attention to tuberosity repair, and the selective use of reverse arthroplasty, as well as a shift in indications towards internal fixation. Reverse shoulder arthroplasty has become extremely popular for patients with cuff-tear arthropathy, and its indications have been expanded to the field of revision surgery. Overall, shoulder arthroplasty is a very successful procedure with predictable pain relief and substantial improvements in motion and function

    Disability and satisfaction after Rotator Cuff decompression or repair: a sex and gender analysis

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Rotator-cuff pathology is the most common cause of pain and disability in the shoulder. Examining the combined effect of biological and societal factors on disability would potentially identify existing differences between men and women with rotator cuff pathology which would help to provide suggestions for better models of care. Purpose of this study was to determine the overall differences in disability between men and women and to examine the relationship between factors that represent sex (biological factors) and gender (non-biological factors) with disability and satisfaction with surgical outcome 6 months after rotator cuff surgery.</p> <p>Methods</p> <p>Patients with impingement syndrome and/or rotator cuff tear who underwent rotator cuff surgery completed the Western Ontario Rotator Cuff (WORC) index, the American Shoulder & Elbow Surgeons (ASES) assessment form, and the Quick Disabilities of the Arm, Shoulder and Hand (QuickDASH) outcome measures prior to surgery and 6 months post-operatively. They also rated their satisfaction with surgery at their follow-up appointment.</p> <p>Results and Discussion</p> <p>One hundred and seventy patients entered into the study (85 men and 85 women). One hundred and sixty patients (94%) completed the 6-month assessment. Women reported more disability both prior to and after surgery. Disability at 6 months was associated with pain-limited range of motion, participation limitation, age and strength. Satisfaction with surgery was associated with level of reported disability, expectations for improved pain, pain-limited range of motion and strength.</p> <p>Conclusions</p> <p>The results of this study indicate that women with rotator cuff pathology suffer from higher levels of pre- and post-operative disability and sex and gender qualities contribute to these differences. Gender-sensitive approach will help to identify existing differences between men and women which will help to promote more effective and tailored care by health professionals.</p

    Origin and insertion of the medial patellofemoral ligament: a systematic review of anatomy.

    Get PDF
    PURPOSE: The medial patellofemoral ligament (MPFL) is the major medial soft-tissue stabiliser of the patella, originating from the medial femoral condyle and inserting onto the medial patella. The exact position reported in the literature varies. Understanding the true anatomical origin and insertion of the MPFL is critical to successful reconstruction. The purpose of this systematic review was to determine these locations. METHODS: A systematic search of published (AMED, CINAHL, MEDLINE, EMBASE, PubMed and Cochrane Library) and unpublished literature databases was conducted from their inception to the 3 February 2016. All papers investigating the anatomy of the MPFL were eligible. Methodological quality was assessed using a modified CASP tool. A narrative analysis approach was adopted to synthesise the findings. RESULTS: After screening and review of 2045 papers, a total of 67 studies investigating the relevant anatomy were included. From this, the origin appears to be from an area rather than (as previously reported) a single point on the medial femoral condyle. The weighted average length was 56 mm with an 'hourglass' shape, fanning out at both ligament ends. CONCLUSION: The MPFL is an hourglass-shaped structure running from a triangular space between the adductor tubercle, medial femoral epicondyle and gastrocnemius tubercle and inserts onto the superomedial aspect of the patella. Awareness of anatomy is critical for assessment, anatomical repair and successful surgical patellar stabilisation. LEVEL OF EVIDENCE: Systematic review of anatomical dissections and imaging studies, Level IV

    Relationship between subscapularis tears and injuries to the biceps pulley

    Get PDF
    The purpose of this study was to analyse the relationship between long head of the biceps brachii (LHBT) lesions and subscapularis tears. The hypothesis was that a bicipital pulley might remain intact, even in the case of a subscapularis tear
    corecore