1,671 research outputs found

    Effective Holographic Theories for low-temperature condensed matter systems

    Get PDF
    The IR dynamics of effective holographic theories capturing the interplay between charge density and the leading relevant scalar operator at strong coupling are analyzed. Such theories are parameterized by two real exponents (γ,δ)(\gamma,\delta) that control the IR dynamics. By studying the thermodynamics, spectra and conductivities of several classes of charged dilatonic black hole solutions that include the charge density back reaction fully, the landscape of such theories in view of condensed matter applications is characterized. Several regions of the (γ,δ)(\gamma,\delta) plane can be excluded as the extremal solutions have unacceptable singularities. The classical solutions have generically zero entropy at zero temperature, except when γ=δ\gamma=\delta where the entropy at extremality is finite. The general scaling of DC resistivity with temperature at low temperature, and AC conductivity at low frequency and temperature across the whole (γ,δ)(\gamma,\delta) plane, is found. There is a codimension-one region where the DC resistivity is linear in the temperature. For massive carriers, it is shown that when the scalar operator is not the dilaton, the DC resistivity scales as the heat capacity (and entropy) for planar (3d) systems. Regions are identified where the theory at finite density is a Mott-like insulator at T=0. We also find that at low enough temperatures the entropy due to the charge carriers is generically larger than at zero charge density.Comment: (v3): Added discussion on the UV completion of the solutions, and on extremal spectra in the charged case. Expanded discusion on insulating extremal solutions. Many other refinements and corrections. 126 pages. 48 figure

    A model for reactive porous transport during re-wetting of hardened concrete

    Full text link
    A mathematical model is developed that captures the transport of liquid water in hardened concrete, as well as the chemical reactions that occur between the imbibed water and the residual calcium silicate compounds residing in the porous concrete matrix. The main hypothesis in this model is that the reaction product -- calcium silicate hydrate gel -- clogs the pores within the concrete thereby hindering water transport. Numerical simulations are employed to determine the sensitivity of the model solution to changes in various physical parameters, and compare to experimental results available in the literature.Comment: 30 page

    Survey of the knowledge, attitude and practice of Nigerian surgery trainees to HIV-infected persons and AIDS patients

    Get PDF
    BACKGROUND: The incidence of HIV infection and AIDS is rising in Nigeria. Surgeons are at risk of occupationally acquired infection as a result of intimate contact with the blood and body fluids of patients. This study set out to determine the knowledge, attitude and risk perception of Nigerian surgery residents to HIV infection and AIDS. METHODS: A self-administered postal questionnaire was sent to all surgery trainees in Nigeria in 1997. RESULTS: Parenteral exposure to patients' blood was reported as occurring 92.5% times, and most respondents assessed their risk of becoming infected with HIV as being moderate at 1–5%. The majority of the respondents were not aware of the CDC guidelines on universal precautions against blood-borne pathogens. Most support a policy of routinely testing all surgical patients for HIV infection but 76.8% work in centers where there is no policy on parenteral exposure to patients' blood and body fluids. Most (85.6%) do not routinely use all the protective measures advocated for the reduction of transmission of blood borne pathogens during surgery, with the majority ascribing this to non-availability. Most want surgeons to be the primary formulators of policy on HIV and surgery while not completely excluding other stakeholders. CONCLUSIONS: The study demonstrates the level of knowledge, attitude and practice of Nigerian surgery trainees in 1997 and the need for policy guidelines to manage all aspects of the healthcare worker (HCW), patients, and HIV/AIDS interaction

    An FPGA-based track finder for the L1 trigger of the CMS experiment at the high luminosity LHC

    Get PDF
    A new tracking system is under development for operation in the CMS experiment at the High Luminosity LHC. It includes an outer tracker which will construct stubs, built by correlating clusters in two closely spaced sensor layers for the rejection of hits from low transverse momentum tracks, and transmit them off-detector at 40 MHz. If tracker data is to contribute to keeping the Level-1 trigger rate at around 750 kHz under increased luminosity, a crucial component of the upgrade will be the ability to identify tracks with transverse momentum above 3 GeV/c by building tracks out of stubs. A concept for an FPGA-based track finder using a fully time-multiplexed architecture is presented, where track candidates are identified using a projective binning algorithm based on the Hough Transform. A hardware system based on the MP7 MicroTCA processing card has been assembled, demonstrating a realistic slice of the track finder in order to help gauge the performance and requirements for a full system. This paper outlines the system architecture and algorithms employed, highlighting some of the first results from the hardware demonstrator and discusses the prospects and performance of the completed track finder

    Emulation of a prototype FPGA track finder for the CMS Phase-2 upgrade with the CIDAF emulation framework

    Get PDF
    The CMS collaboration is preparing a major upgrade of its detector, so it can operate during the high luminosity run of the LHC from 2026. The upgraded tracker electronics will reconstruct the trajectories of charged particles within a latency of a few microseconds, so that they can be used by the level-1 trigger. An emulation framework, CIDAF, has been developed to provide a reference for a proposed FPGA-based implementation of this track finder, which employs a Time-Multiplexed (TM) technique for data processing.The research leading to these results has received funding from the People Programme (Marie Curie Actions) of the European Unions Seventh Framework Programme FP7/2007- 2013/ under REA grant agreement n [317446] INFIERI “Intelligent Fast Interconnected and Efficient Devices for Frontier Exploitation in Research and Industry”. This work was supported in part by the the UK Science and Technology Facilities Council, we gratefully acknowledge their support

    Hybridization and hybrid speciation under global change

    Get PDF
    An unintended consequence of global change is an increase in opportunities for hybridization among previously isolated lineages. Here we illustrate how global change can facilitate the breakdown of reproductive barriers and the formation of hybrids, drawing on the flora of the British Isles for insight. Although global change may ameliorate some of the barriers preventing hybrid establishment, for example by providing new ecological niches for hybrids, it will have limited effects on environment-independent post-zygotic barriers. For example, genic incompatibilities and differences in chromosome numbers and structure within hybrid genomes are unlikely to be affected by global change. We thus speculate that global change will have a larger effect on eroding pre-zygotic barriers (eco-geographical isolation and phenology) than post-zygotic barriers, shifting the relative importance of these two classes of reproductive barriers from what is usually seen in naturally produced hybrids where pre-zygotic barriers are the largest contributors to reproductive isolation. Although the long-term fate of neo-hybrids is still to be determined, the massive impact of global change on the dynamics and distribution of biodiversity generates an unprecedented opportunity to study large numbers of unpredicted, and often replicated, hybridization ‘experiments’, allowing us to peer into the birth and death of evolutionary lineages

    In vivo assessment of catheter positioning accuracy and prolonged irradiation time on liver tolerance dose after single-fraction 192Ir high-dose-rate brachytherapy

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>To assess brachytherapy catheter positioning accuracy and to evaluate the effects of prolonged irradiation time on the tolerance dose of normal liver parenchyma following single-fraction irradiation with <sup>192 </sup>Ir.</p> <p>Materials and methods</p> <p>Fifty patients with 76 malignant liver tumors treated by computed tomography (CT)-guided high-dose-rate brachytherapy (HDR-BT) were included in the study. The prescribed radiation dose was delivered by 1 - 11 catheters with exposure times in the range of 844 - 4432 seconds. Magnetic resonance imaging (MRI) datasets for assessing irradiation effects on normal liver tissue, edema, and hepatocyte dysfunction, obtained 6 and 12 weeks after HDR-BT, were merged with 3D dosimetry data. The isodose of the treatment plan covering the same volume as the irradiation effect was taken as a surrogate for the liver tissue tolerance dose. Catheter positioning accuracy was assessed by calculating the shift between the 3D center coordinates of the irradiation effect volume and the tolerance dose volume for 38 irradiation effects in 30 patients induced by catheters implanted in nearly parallel arrangement. Effects of prolonged irradiation were assessed in areas where the irradiation effect volume and tolerance dose volume did not overlap (mismatch areas) by using a catheter contribution index. This index was calculated for 48 irradiation effects induced by at least two catheters in 44 patients.</p> <p>Results</p> <p>Positioning accuracy of the brachytherapy catheters was 5-6 mm. The orthogonal and axial shifts between the center coordinates of the irradiation effect volume and the tolerance dose volume in relation to the direction vector of catheter implantation were highly correlated and in first approximation identically in the T1-w and T2-w MRI sequences (<it>p </it>= 0.003 and <it>p </it>< 0.001, respectively), as were the shifts between 6 and 12 weeks examinations (<it>p </it>= 0.001 and <it>p </it>= 0.004, respectively). There was a significant shift of the irradiation effect towards the catheter entry site compared with the planned dose distribution (<it>p </it>< 0.005). Prolonged treatment time increases the normal tissue tolerance dose. Here, the catheter contribution indices indicated a lower tolerance dose of the liver parenchyma in areas with prolonged irradiation (<it>p </it>< 0.005).</p> <p>Conclusions</p> <p>Positioning accuracy of brachytherapy catheters is sufficient for clinical practice. Reduced tolerance dose in areas exposed to prolonged irradiation is contradictory to results published in the current literature. Effects of prolonged dose administration on the liver tolerance dose for treatment times of up to 60 minutes per HDR-BT session are not pronounced compared to effects of positioning accuracy of the brachytherapy catheters and are therefore of minor importance in treatment planning.</p

    Evolutionary Analyses of Staphylococcus aureus Identify Genetic Relationships between Nasal Carriage and Clinical Isolates

    Get PDF
    Nasal carriage of Staphylococcus aureus has long been hypothesized to be a major vector for the transmission of virulent strains throughout the community. To address this hypothesis, we have analyzed the relatedness between a cohort of nasal carriage strains and clinical isolates to understand better the genetic conformity therein. To assess the relatedness between nasal carriage and clinical isolates of S. aureus, a genetic association study was conducted using multilocus sequence typing (MLST) and typing of the hypervariable regions of clumping factor and fibronectin binding protein genes. At all loci analyzed, genetic associations between both nasal carriage and clinical isolates were observed. Computational analyses of MLST data indicate that nasal carriage and clinical isolates belong to the same genetic clusters (clades), despite differences in sequence type assignments. Genetic analyses of the hypervariable regions from the clumping factor and fibronectin binding protein genes revealed that not only do clinically relevant strains belong to identical genetic lineages as the nasal carriage isolates within our cohort, but they also exhibit 100% sequence similarity within these regions. The findings of this report indicate that strains of S. aureus being carried asymptomatically throughout the community via nasal colonization are genetically related to those responsible for high levels of morbidity and mortality

    Absorption and Metabolism of cis-9,trans-11-CLA and of Its Oxidation Product 9,11-Furan Fatty Acid by Caco-2 Cells

    Get PDF
    Furan fatty acids (furan-FA) can be formed by auto-oxidation of conjugated linoleic acids (CLA) and may therefore be ingested when CLA-containing foodstuff is consumed. Due to the presence of a furan ring structure, furan-FA may have toxic properties, however, these substances are toxicologically not well characterized so far. Here we show that 9,11-furan-FA, the oxidation product of the major CLA isomer cis-9,trans-11-CLA (c9,t11-CLA), is not toxic to human intestinal Caco-2 cells up to a level of 100 μM. Oil-Red-O staining indicated that 9,11-furan-FA as well as c9,t11-CLA and linoleic acid are taken up by the cells and stored in the form of triglycerides in lipid droplets. Chemical analysis of total cellular lipids revealed that 9,11-furan-FA is partially elongated probably by the enzymatic activity of cellular fatty acid elongases whereas c9,t11-CLA is partially converted to other isomers such as c9,c11-CLA or t9,t11-CLA. In the case of 9,11-furan-FA, there is no indication for any modification or activation of the furan ring system. From these results, we conclude that 9,11-furan-FA has no properties of toxicological relevance at least for Caco-2 cells which serve as a model for enterocytes of the human small intestine

    The purple line as a measure of labour progress: a longitudinal study

    Get PDF
    Background: Vaginal examination (VE) and assessment of the cervix is currently considered to be the gold standard for assessment of labour progress. It is however inherently imprecise with studies indicating an overall accuracy for determining the diameter of the cervix at between 48-56%. Furthermore, VEs can be unpleasant, intrusive and embarrassing for women, and are associated with the risk of introducing infection. In light of increasing concern world wide about the use of routine interventions in labour it may be time to consider alternative, less intrusive means of assessing progress in labour. The presence of a purple line during labour, seen to rise from the anal margin and extend between the buttocks as labour progresses has been reported. The study described in this paper aimed to assess in what percentage of women in labour a purple line was present, clear and measurable and to determine if any relationship existed between the length of the purple line and cervical dilatation and/or station of the fetal head. Methods: This longitudinal study observed 144 women either in spontaneous labour (n=112) or for induction of labour (n=32) from admission through to final VE. Women were examined in the lateral position and midwives recorded the presence or absence of the line throughout labour immediately before each VE. Where present, the length of the line was measured using a disposable tape measure. Within subjects correlation, chi-squared test for independence, and independent samples t-test were used to analyse the data. Results: The purple line was seen at some point in labour for 109 women (76%). There was a medium positive correlation between length of the purple line and cervical dilatation (r=+0.36, n=66, P=0.0001) and station of the fetal head (r=+0.42, n=56, P&lt;0.0001). Conclusions: The purple line does exist and there is a medium positive correlation between its length and both cervical dilatation and station of the fetal head. Where the line is present, it may provide a useful guide for clinicians of labour progress along side other measures. Further research is required to assess whether measurement of the line is acceptable to women in labour and also clinicians
    corecore