11 research outputs found

    Proportion among the segments of the normal tricuspid valve annulus: parameter for valve annuloplasty

    Get PDF
    OBJECTIVE: The purpose of this study was to determine the proportions among the segments of the human tricuspid valve annulus. METHODS: A descriptive autopsy study was made of 30 human hearts without fixation, within six hours of death, without congenital or acquired lesions and without tricuspid regurgitation. Tricuspid valve insufficiency was excluded by the infusion of pressurized water in the right ventricle with the pulmonary valve closed. Digital images of the tricuspid ring in its anatomical position and after flattening were analyzed by specific software. The mean measurements and ratios were compared in the two different situations. RESULTS: The mean measurements of the perimeter, septal and antero-posterior segments of the tricuspid ring in the anatomical position were: 105mm (&plusmn;12.7), 30.6mm (&plusmn;3.7) and 74mm (&plusmn;9.4), respectively. When flattened, the mean measurement of the perimeter was 117.5mm (&plusmn;13.3) and sizes of the septal, anterior and posterior segments were 32mm (&plusmn;3.7), 46.3mm (&plusmn;8.3) and 39.1mm (&plusmn;8.5), respectively. The mean ratio between the antero-posterior and septal segments was 2.43 (&plusmn;0.212) in the anatomical position and when flattened it was 2.67 (&plusmn;0.304). Statistical differences were observed in the measurements of perimeter (p<0.0001), septal segment (p=0.003) and antero-posterior segment (p<0.0001) in both situations. Statistical differences also occurred in the ratios between the antero-posterior and septal segments (p=0.0005). CONCLUSION: The proportion between the septal and antero-posterior segments of the normal human tricuspid valve is 1:2.43. Flattening the tricuspid ring to measure the segments, changes the values and the ratios between them.OBJETIVO: Determinar a proporção existente entre os segmentos do anel da valva tricúspide normal em humanos. MÉTODO: Foram estudados 30 corações de cadáveres humanos não formolizados, com menos de 6h de período post-mortem, sem lesões congênitas ou adquiridas e com valvas tricúspides continentes. A continência valvar foi confirmada por injeção de água sob pressão no interior do ventrículo direito estando a valva pulmonar fechada. Fotos digitais da valva tricúspide com o anel valvar íntegro, e após secção e retificação, foram avaliadas por programa de computador. Compararam-se as medidas médias e as razões entre elas nas condições de anel íntegro e retificado. RESULTADOS: Com o anel valvar íntegro, os valores médios do perímetro, segmento septal e ântero-posterior foram 105mm (&plusmn;12,7), 30,6mm (&plusmn;3,7) e 74mm (&plusmn;9,4), respectivamente. Com o anel valvar retificado, os valores médios foram 117,5mm (&plusmn;13,3), 32mm (&plusmn;3,7), 46,3mm (&plusmn;8,3) e 39,1mm (&plusmn;8,5), respectivamente para perímetro, segmento septal, anterior e posterior. As razões médias entre o segmento ântero-posterior e o septal foram 2,43 (&plusmn;0,212) e 2,67 (&plusmn;0,304), respectivamente, em anéis íntegros e retificados. Houve diferenças significantes nas medidas do perímetro (p<0,0001), do segmento septal (p=0,003) e do segmento ântero-posterior (p<0,0001) entre anéis íntegros e retificados. As razões entre segmento ântero-posterior e septal também apresentaram diferença significante (p=0,0005). CONCLUSÃO: A proporção entre o segmento septal e o segmento ântero-posterior, do anel da valva tricúspide normal em humanos, é igual a 1: 2,43. A secção e retificação do anel tricuspídeo altera as medidas de seus segmentos e suas relações.26227

    Tricuspid valve repair using the proportion between segments of normal tricuspid annulus as a parameter for annuloplasty

    Get PDF
    OBJECTIVE: To determine the proportion between the segments of the normal human tricuspid valve (TV) annulus and its use as a parameter for ring annuloplasty in vitro and in vivo. METHODS: Digital images of the tricuspid ring of 30 human cadaveric hearts, without fixation and without tricuspid regurgitation (TR), were analyzed and the proportion between the antero-posterior and septal segments was determined. This proportion was used for TV annuloplasty with bovine pericardium (BP) flexible rings on 15 hearts from adult cadavers with TR and ring dilatation. The same proportion and technique were used for TV repair on 11 patients with functional TR. Preoperatively, seven patients had severe and four moderate TR; five patients were class IV and six class III (NYHA). RESULTS:The mean ratio between the antero-posterior and septal segments was 2.43±0.212 in the 30 hearts without TR. The mean size of the BP flexible ring used for in vitro surgical procedure was 71.5±5.2 mm, median 70 mm, and there was no TR after that in all 15 hearts. The mean size of the orthesis used on the patients was 73.4±6.5 mm, median 72 mm. There was 1 hospital death. Six months after surgery, 7 patients had no TR and 3 had mild TR; 6 patients were in NYHA class I, 3 in class II and 1 in class III. CONCLUSION: The use of the ratio 2.43:1 between the anterior-posterior and septal segments as a parameter in tricuspid valve annuloplasty with a bovine pericardium flexible ring leads to satisfactory results.OBJETIVO: Determinar a proporção existente entre os segmentos do anel da valva tricúspide (VT) normal e aplicála na realização da anuloplastia tricúspidea in vitro e in vivo. MÉTODOS: Imagens digitais do anel tricuspídeo de 30 corações de cadáveres humanos, sem formolização e sem insuficiência tricúspide (IT), foram analisadas e a proporção entre os segmentos ântero-posterior e septal foi determinada. Esta proporção foi utilizada na anuloplastia da VT com anel maleável de pericárdio bovino (PB), em 15 corações de cadáveres com IT e dilatação do anel valvar. A mesma proporção e técnica foi utilizada na realização de anuloplastia tricuspídea, em 11 pacientes com IT funcional, entre os quais, sete possuíam IT importante e quatro, moderada; cinco apresentavam insuficiência cardíaca (IC) classe IV (NYHA) e seis, classe III. RESULTADOS: Nas valvas continentes de cadáveres, a razão média entre o segmento ântero-posterior e septal foi 2,43±0,212. O tamanho médio dos anéis maleáveis PB utilizados in vitro foi 71,5±5,2mm e mediana 70mm. Todas as valvas ficaram continentes após a anuloplastia tricuspídea in vitro. O tamanho médio do anel maleável PB utilizado in vivo foi 73,4±6,5mm e mediana 72mm. Ocorreu um (9,1%) óbito. Na avaliação com 6 meses de pós-operatório, sete pacientes não possuíam IT e três possuíam IT leve; seis pacientes apresentavam IC classe I, três, classe II e um, classe III. CONCLUSÃO: O uso da proporção de 2,43:1 entre os segmentos ântero-posterior e septal, como um parâmetro na anuloplastia da VT, utilizando anel maleável de pericárdio bovino, demonstrou resultados iniciais favoráveis.39339

    Plastia tricúspide utilizando anuloplastia baseada na proporção entre os segmentos do anel da valva tricúspide normal

    No full text
    OBJETIVO: Determinar a proporção existente entre os segmentos do anel da valva tricúspide (VT) normal e aplicála na realização da anuloplastia tricúspidea "in vitro" e "in vivo". MÉTODOS: Imagens digitais do anel tricuspídeo de 30 corações de cadáveres humanos, sem formolização e sem insuficiência tricúspide (IT), foram analisadas e a proporção entre os segmentos ântero-posterior e septal foi determinada. Esta proporção foi utilizada na anuloplastia da VT com anel maleável de pericárdio bovino (PB), em 15 corações de cadáveres com IT e dilatação do anel valvar. A mesma proporção e técnica foi utilizada na realização de anuloplastia tricuspídea, em 11 pacientes com IT funcional, entre os quais, sete possuíam IT importante e quatro, moderada; cinco apresentavam insuficiência cardíaca (IC) classe IV (NYHA) e seis, classe III. RESULTADOS: Nas valvas continentes de cadáveres, a razão média entre o segmento ântero-posterior e septal foi 2,43±0,212. O tamanho médio dos anéis maleáveis PB utilizados "in vitro" foi 71,5±5,2mm e mediana 70mm. Todas as valvas ficaram continentes após a anuloplastia tricuspídea "in vitro". O tamanho médio do anel maleável PB utilizado "in vivo" foi 73,4±6,5mm e mediana 72mm. Ocorreu um (9,1%) óbito. Na avaliação com 6 meses de pós-operatório, sete pacientes não possuíam IT e três possuíam IT leve; seis pacientes apresentavam IC classe I, três, classe II e um, classe III. CONCLUSÃO: O uso da proporção de 2,43:1 entre os segmentos ântero-posterior e septal, como um parâmetro na anuloplastia da VT, utilizando anel maleável de pericárdio bovino, demonstrou resultados iniciais favoráveis
    corecore