39 research outputs found

    Cardiovascular Magnetic Resonance Imaging in Experimental Models

    Get PDF
    Cardiovascular magnetic resonance (CMR) imaging is the modality of choice for clinical studies of the heart and vasculature, offering detailed images of both structure and function with high temporal resolution

    Effect of angiotensin-converting enzyme inhibitor and angiotensin receptor blocker initiation on organ support-free days in patients hospitalized with COVID-19

    Get PDF
    IMPORTANCE Overactivation of the renin-angiotensin system (RAS) may contribute to poor clinical outcomes in patients with COVID-19. Objective To determine whether angiotensin-converting enzyme (ACE) inhibitor or angiotensin receptor blocker (ARB) initiation improves outcomes in patients hospitalized for COVID-19. DESIGN, SETTING, AND PARTICIPANTS In an ongoing, adaptive platform randomized clinical trial, 721 critically ill and 58 non–critically ill hospitalized adults were randomized to receive an RAS inhibitor or control between March 16, 2021, and February 25, 2022, at 69 sites in 7 countries (final follow-up on June 1, 2022). INTERVENTIONS Patients were randomized to receive open-label initiation of an ACE inhibitor (n = 257), ARB (n = 248), ARB in combination with DMX-200 (a chemokine receptor-2 inhibitor; n = 10), or no RAS inhibitor (control; n = 264) for up to 10 days. MAIN OUTCOMES AND MEASURES The primary outcome was organ support–free days, a composite of hospital survival and days alive without cardiovascular or respiratory organ support through 21 days. The primary analysis was a bayesian cumulative logistic model. Odds ratios (ORs) greater than 1 represent improved outcomes. RESULTS On February 25, 2022, enrollment was discontinued due to safety concerns. Among 679 critically ill patients with available primary outcome data, the median age was 56 years and 239 participants (35.2%) were women. Median (IQR) organ support–free days among critically ill patients was 10 (–1 to 16) in the ACE inhibitor group (n = 231), 8 (–1 to 17) in the ARB group (n = 217), and 12 (0 to 17) in the control group (n = 231) (median adjusted odds ratios of 0.77 [95% bayesian credible interval, 0.58-1.06] for improvement for ACE inhibitor and 0.76 [95% credible interval, 0.56-1.05] for ARB compared with control). The posterior probabilities that ACE inhibitors and ARBs worsened organ support–free days compared with control were 94.9% and 95.4%, respectively. Hospital survival occurred in 166 of 231 critically ill participants (71.9%) in the ACE inhibitor group, 152 of 217 (70.0%) in the ARB group, and 182 of 231 (78.8%) in the control group (posterior probabilities that ACE inhibitor and ARB worsened hospital survival compared with control were 95.3% and 98.1%, respectively). CONCLUSIONS AND RELEVANCE In this trial, among critically ill adults with COVID-19, initiation of an ACE inhibitor or ARB did not improve, and likely worsened, clinical outcomes. TRIAL REGISTRATION ClinicalTrials.gov Identifier: NCT0273570

    Retrospective evaluation of whole exome and genome mutation calls in 746 cancer samples

    No full text
    Funder: NCI U24CA211006Abstract: The Cancer Genome Atlas (TCGA) and International Cancer Genome Consortium (ICGC) curated consensus somatic mutation calls using whole exome sequencing (WES) and whole genome sequencing (WGS), respectively. Here, as part of the ICGC/TCGA Pan-Cancer Analysis of Whole Genomes (PCAWG) Consortium, which aggregated whole genome sequencing data from 2,658 cancers across 38 tumour types, we compare WES and WGS side-by-side from 746 TCGA samples, finding that ~80% of mutations overlap in covered exonic regions. We estimate that low variant allele fraction (VAF < 15%) and clonal heterogeneity contribute up to 68% of private WGS mutations and 71% of private WES mutations. We observe that ~30% of private WGS mutations trace to mutations identified by a single variant caller in WES consensus efforts. WGS captures both ~50% more variation in exonic regions and un-observed mutations in loci with variable GC-content. Together, our analysis highlights technological divergences between two reproducible somatic variant detection efforts

    Head and neck manifestations of granulomatosis with polyangiitis

    No full text
    Granulomatosis with polyangiitis is a rare autoimmune condition which causes respiratory tract granulomas, small to medium vessel vasculitis and renal disease. Head and neck manifestations are some of the most common presentations of the condition, with a significant proportion of patients experiencing sinonasal disease alone. The recognition of suggestive imaging findings, in combination with clinical history and serology, aids the diagnosis and appropriate treatment. This pictorial review describes and illustrates the head and neck imaging features of granulomatosis with polyangiitis, highlighting the range of CT and MRI findings of upper aerodigestive tract, orbital and skull-base disease. Recognition of the radiological appearances is of importance, since clinical presentations may be non-specific and limited disease may have negative serology. Imaging features may overlap with other pathologies so important differential diagnoses will be considered, and these are particularly relevant in the context of treatment resistance

    Comparison of segmentation methods for MRI measurement of cardiac function in rats

    No full text
    Purpose: To establish the accuracy, intra-and inter-observer variabilities of four different segmentation methods for measuring cardiac functional parameters in healthy and infarcted rat hearts.Materials and Methods: Six Wistar rats were imaged before and after myocardial infarction using an electrocardiogram and respiratory-gated spoiled gradient echo sequence. Blinded and randomized datasets were analyzed by various semi-automatic and manual segmentation methods to compare their measurement bias and variability. In addition, the accuracy of these methods was assessed by comparison with reference measurements acquired from high-resolution three-dimensional (3D) datasets of a heart phantom.Results: Relative inter-and intra-observer variability were found to be similar for all four methods. Semiautomatic segmentation methods reduced analysis time by up to 70%, while yielding similar measurement bias and variability compared with manual segmentation. Semi-automatic methods were found to underestimate the ejection fraction for healthy hearts compared with manual segmentation while overestimating them in infarcted hearts. However, semi-automatic segmentation of short axis slices agreed better with 3D reference scans of a heart phantom compared with manual segmentation.Conclusion: Semi-automatic segmentation methods are faster than manual segmentation, while offering a similar intra-and inter-observer variability. However, a potential bias has been observed between healthy and infarcted sidered when selecting the most appropriate analysis technique

    Extracting more for less: multi‐echo MP2RAGE for simultaneous T 1 ‐weighted imaging, T 1 mapping, mapping, SWI, and QSM from a single acquisition

    Get PDF
    To demonstrate simultaneous T -weighted imaging, T mapping, mapping, SWI, and QSM from a single multi-echo (ME) MP2RAGE acquisition.A single-echo (SE) MP2RAGE sequence at 7 tesla was extended to ME with 4 bipolar gradient echo readouts. T -weighted images and T maps calculated from individual echoes were combined using sum of squares and averaged, respectively. ME-combined SWI and associated minimum intensity projection images were generated with TE-adjusted homodyne filters. A QSM reconstruction pipeline was used, including a novel phase-offsets estimation from multi-echoes (POEM) method to properly combine the phase images from the 32 receiver channels. Measurements of susceptibility, , and T of brain tissue from ME-MP2RAGE were compared with those from standard ME-gradient echo and SE-MP2RAGE.The ME combined T -weighted, T map, SWI, and minimum intensity projection images showed increased SNRs compared to the SE results. The proposed POEM coil combination method led to QSM results free of phase-singularity artifacts, which were present in the standard adaptive combination method. T -weighted, T , and susceptibility maps from ME-MP2RAGE were comparable to those obtained from SE-MP2RAGE and ME-gradient echo, whereas maps showed increased blurring and reduced SNR. T , , and susceptibility values of brain tissue from ME-MP2RAGE were consistent with those from SE-MP2RAGE and ME-gradient echo.High-resolution structural T weighted imaging, T mapping, mapping, SWI, and QSM can be extracted from a single 8.5-min ME-MP2RAGE acquisition using a customized reconstruction pipeline. This method can be applied to replace separate SE-MP2RAGE and ME-gradient echo acquisitions to significantly shorten total scan time

    Cardiac phenotyping in ex vivo murine embryos using µMRI

    No full text
    Microscopic MRI (microMRI) is an emerging technique for high-throughput phenotyping of transgenic mouse embryos, and is capable of visualising abnormalities in cardiac development. To identify cardiac defects in embryos, we have optimised embryo preparation and MR acquisition parameters to maximise image quality and assess the phenotypic changes in chromodomain helicase DNA-binding protein 7 (Chd7) transgenic mice. microMRI methods rely on tissue penetration with a gadolinium chelate contrast agent to reduce tissue T(1), thus improving signal-to-noise ratio (SNR) in rapid gradient echo sequences. We investigated 15.5 days post coitum (dpc) wild-type CD-1 embryos fixed in gadolinium-diethylene triamine pentaacetic acid (Gd-DTPA) solutions for either 3 days (2 and 4 mM) or 2 weeks (2, 4, 8 and 16 mM). To assess penetration of the contrast agent into heart tissue and enable image contrast simulations, T(1) and T(*) (2) were measured in heart and background agarose. Compared to 3-day, 2-week fixation showed reduced mean T(1) in the heart at both 2 and 4 mM concentrations (p < 0.0001), resulting in calculated signal gains of 23% (2 mM) and 29% (4 mM). Using T(1) and T(*) (2) values from 2-week concentrations, computer simulation of heart and background signal, and ex vivo 3D gradient echo imaging, we demonstrated that 2-week fixed embryos in 8 mM Gd-DTPA in combination with optimised parameters (TE/TR/alpha/number of averages: 9 ms/20 ms/60 degrees /7) produced the largest SNR in the heart (23.2 +/- 1.0) and heart chamber contrast-to-noise ratio (CNR) (27.1 +/- 1.6). These optimised parameters were then applied to an MRI screen of embryos heterozygous for the gene Chd7, implicated in coloboma of the eye, heart defects, atresia of the choanae, retardation of growth, genital/urinary abnormalities, ear abnormalities and deafness (CHARGE) syndrome (a condition partly characterised by cardiovascular birth defects in humans). A ventricular septal defect was readily identified in the screen, consistent with the human phenotype
    corecore