3,465 research outputs found

    A ducted wind turbine simulation model for building simulation

    Get PDF
    Power production is shifting away from centralized generation plants to production of heat and power at the point of demand. A technology that may play a part in this shift is the ducted wind turbine (DWT). The emergence of small building integrated micro turbines opens up the possibility of utilizing the differential pressures occurring around buildings for local power production. This paper describes work to develop and test a simple mathematical model of a ducted wind turbine and its integration within a building simulation tool. A case study in which the simulation model will be used to analyse of the likely power output from a building incorporating ducted wind turbines within the façade is also presented

    A dusty origin for the correlation between protoplanetary disc accretion rates and dust masses

    Get PDF
    ABSTRACT Recent observations have uncovered a correlation between the accretion rates (measured from the UV continuum excess) of protoplanetary discs and their masses inferred from observations of the submm continuum. While viscous evolution models predict such a correlation, the predicted values are in tension with data obtained from the Lupus and Upper Scorpius star-forming regions; for example, they underpredict the scatter in accretion rates, particularly in older regions. Here, we argue that since the submm observations trace the discs’ dust, by explicitly modelling the dust grain growth, evolution, and emission, we can better understand the correlation. We show that for turbulent viscosities with α ≲ 10−3, the depletion of dust from the disc due to radial drift means we can reproduce the range of masses and accretion rates seen in the Lupus and Upper Sco data sets. One consequence of this model is that the upper locus of accretion rates at a given dust mass does not evolve with the age of the region. Moreover, we find that internal photoevaporation is necessary to produce the lowest accretion rates observed. In order to replicate the correct dust masses at the time of disc dispersal, we favour relatively low photoevaporation rates ≲ 10−9 M⊙ yr−1 for most sources but cannot discriminate between EUV or X-ray-driven winds. A limited number of sources, particularly in Lupus, are shown to have higher masses than predicted by our models which may be evidence for variations in the properties of the dust or dust trapping induced in substructures.</jats:p

    GLUT-1 deficiency presenting with seizures and reversible leukoencephalopathy on MRI imaging

    Get PDF
    Glucose transporter type 1 (GLUT1) deficiency syndrome is a well recognised genetic neurometabolic disorder typically presenting with progressive encephalopathy, acquired microcephaly and drug-resistant epilepsy. Imaging is normal in the majority. Here we describe a 5-month-old boy who presented with motor delay, myoclonic jerks and tonic-clonic seizures. His MRI brain scan revealed confluent symmetrical T2 hyperintense signal abnormality in both anterior frontal lobes and delayed myelination. Neurometabolic screen revealed low CSF glucose and lactate levels. A pathogenic de novo heterozygous mutation in SLC2A1 (c.275+1G > A) confirmed the diagnosis of GLUT1 deficiency. Ketogenic diet resulted in a dramatic termination of his seizures at 72 h. At 15 months, he continued to be seizure free with marked developmental catch up. Repeat imaging revealed a significant resolution of the previously seen changes. This case suggests that GLUT1 deficiency should be considered in the differential diagnosis of infants with suspected genetic leukoencephalopathies with important treatment implications

    The BaSICS (Baby Skin Integrity Comparison Survey) study : a prospective experimental study using maternal observations to report the effect of baby wipes on the incidence of irritant diaper dermatitis in infants, from birth to eight weeks of age

    Get PDF
    Background Baby wipes have been shown to be safe and effective in maintaining skin integrity when compared to the use of water alone. However, no previous study has compared different formulations of wipe. The aim of the BaSICS study was to identify any differences in incidence of irritant diaper dermatitis (IDD) in infants assigned to three different brands of wipe, all marketed as suitable for neonates, but which contained varying numbers of ingredients. Methods Women were recruited during the prenatal period. Participants were randomly assigned to receive one of three brands of wipe for use during the first eight weeks following childbirth. All participants received the same nappies. Participants reported their infant’s skin integrity on a scale of 1 to 5 daily using a bespoke smartphone application. Analysis of effect of brand on clinically significant IDD (score 3 or more) incidence was conducted using a negative binomial generalised linear model, controlling for possible confounders at baseline. Analysts were blind to brand of wipe. Results Of 737 women enrolled, 15 were excluded (admitted to neonatal intensive care, premature or other infant health issues). Of the 722 eligible babies, 698 (97%) remained in the study for the full 8-week duration, 24.6% of whom had IDD at some point during the study. Mothers using the brand with the fewest ingredients reported fewer days of clinically significant nappy rash (score≥3) than participants using the two other brands (p=0.002 and p<0.001). Severe IDD (grades 4 and 5) was rare (2.4%). Conclusions Rarity of severe IDD suggested that sensitive formula baby wipes are safe when used in cleansing babies from birth to eight weeks during nappy changes. The brand with fewest ingredients had significantly fewer days of clinically significant IDD. Daily observations recorded on a smartphone application proved to be a highly acceptable method of obtaining real-time data on IDD

    Effect of geometric parameters on the behavior of bolted GFRP pultruded plates

    Get PDF
    Abstract : This paper presents the effect of geometric parameters on the behavior of bolted GFRP pultruded plates for civil engineering applications. After a literature review, results of an experimental analysis investigating the behavior of GFRP-to-steel single-lap bolted connections are presented. Then, a finite element analysis validated by experimental data is used to evaluate the effects of the end-distance, side-distance, gage, pitch and plate properties on the strength and failure mode of the connection. A critical examination of geometric recommendations proposed in design references is presented. Bearing failure caused by contact of the bolt on the GFRP plate is usually defined as the preferred failure mode. With highly orthotropic plate, this type of failure was found to be less likely to occur when loading is applied in the pultruded direction. The investigation showed that the minimum end-distance and pitch-distance recommended by design references usually produce a connection with the maximum capacity. However, it was found that the minimum side-distance recommended by these references does not necessarily lead to the maximum capacity for one-bolt and for two-bolt in a column connections
    corecore