1,780 research outputs found

    ‘VIOLET’: a fluorescence-based simulation exercise for training healthcare workers in the use of personal protective equipment

    Get PDF
    Background Healthcare workers caring for patients with high-consequence infectious diseases (HCIDs) require protection from pathogen exposure, for example by wearing personal protective equipment (PPE). Protection is acquired through the inherent safety of the PPE components, but also their safe and correct use, supported by adequate training and user familiarity. However, the evidence base for HCID PPE ensembles and any associated training is lacking, with subsequent variation between healthcare providers. Aim To develop an evidence-based assessment and training tool for evaluating PPE ensembles and doffing protocols, in the assessment of patients with suspected HCIDs. Methods VIOLET (Visualising Infection with Optimised Light for Education and Training) comprises a healthcare mannequin adapted to deliver simulated bodily fluids containing UV-fluorescent tracers. On demand and remotely operated, the mannequin projectile vomits (blue), coughs (red), has diarrhoea (yellow) and is covered in sweat (orange). Wearing PPE, healthcare staff participate in an HCID risk assessment and examination of the ‘patient’, thereby becoming exposed to these bodily fluids. Contamination of PPE is visualized and body-mapped under UV light before and after removal. Observational findings and participant feedback, around its use as a training exercise, is also recorded. Findings Significant contamination from different exposure events was seen, enabling evaluation of PPE and doffing procedures used. Observational data and participant feedback demonstrated its strengths and success as a training technique. Conclusion Simulation exercises using VIOLET provide evidence-based assessment of PPE ensembles, and are a valuable resource for training of healthcare staff in wearing and safe doffing of PPE

    Use of ultraviolet-fluorescence-based simulation in evaluation of personal protective equipment worn for first assessment and care of a patient with suspected high-consequence infectious disease

    Get PDF
    Background: Variations currently exist across the UK in the choice of personal protective equipment (PPE) used by healthcare workers when caring for patients with suspected high-consequence infectious diseases (HCIDs). Aim: To test the protection afforded to healthcare workers by current PPE ensembles during assessment of a suspected HCID case, and to provide an evidence base to justify proposal of a unified PPE ensemble for healthcare workers across the UK. Methods: One ‘basic level’ (enhanced precautions) PPE ensemble and five ‘suspected case’ PPE ensembles were evaluated in volunteer trials using ‘Violet’; an ultraviolet-fluorescence-based simulation exercise to visualize exposure/contamination events. Contamination was photographed and mapped. Findings: There were 147 post-simulation and 31 post-doffing contamination events, from a maximum of 980, when evaluating the basic level of PPE. Therefore, this PPE ensemble did not afford adequate protection, primarily due to direct contamination of exposed areas of the skin. For the five suspected case ensembles, 1584 post-simulation contamination events were recorded, from a maximum of 5110. Twelve post-doffing contamination events were also observed (face, two events; neck, one event; forearm, one event; lower legs, eight events). Conclusion: All suspected case PPE ensembles either had post-doffing contamination events or other significant disadvantages to their use. This identified the need to design a unified PPE ensemble and doffing procedure, incorporating the most protective PPE considered for each body area. This work has been presented to, and reviewed by, key stakeholders to decide on a proposed unified ensemble, subject to further evaluation

    Multilayered feed forward Artificial Neural Network model to predict the average summer-monsoon rainfall in India

    Full text link
    In the present research, possibility of predicting average summer-monsoon rainfall over India has been analyzed through Artificial Neural Network models. In formulating the Artificial Neural Network based predictive model, three layered networks have been constructed with sigmoid non-linearity. The models under study are different in the number of hidden neurons. After a thorough training and test procedure, neural net with three nodes in the hidden layer is found to be the best predictive model.Comment: 19 pages, 1 table, 3 figure

    The Radio Sky at Meter Wavelengths: m-Mode Analysis Imaging with the Owens Valley Long Wavelength Array

    Get PDF
    A host of new low-frequency radio telescopes seek to measure the 21-cm transition of neutral hydrogen from the early universe. These telescopes have the potential to directly probe star and galaxy formation at redshifts 20≳z≳720 \gtrsim z \gtrsim 7, but are limited by the dynamic range they can achieve against foreground sources of low-frequency radio emission. Consequently, there is a growing demand for modern, high-fidelity maps of the sky at frequencies below 200 MHz for use in foreground modeling and removal. We describe a new widefield imaging technique for drift-scanning interferometers, Tikhonov-regularized mm-mode analysis imaging. This technique constructs images of the entire sky in a single synthesis imaging step with exact treatment of widefield effects. We describe how the CLEAN algorithm can be adapted to deconvolve maps generated by mm-mode analysis imaging. We demonstrate Tikhonov-regularized mm-mode analysis imaging using the Owens Valley Long Wavelength Array (OVRO-LWA) by generating 8 new maps of the sky north of δ=−30∘\delta=-30^\circ with 15 arcmin angular resolution, at frequencies evenly spaced between 36.528 MHz and 73.152 MHz, and ∼\sim800 mJy/beam thermal noise. These maps are a 10-fold improvement in angular resolution over existing full-sky maps at comparable frequencies, which have angular resolutions ≥2∘\ge 2^\circ. Each map is constructed exclusively from interferometric observations and does not represent the globally averaged sky brightness. Future improvements will incorporate total power radiometry, improved thermal noise, and improved angular resolution -- due to the planned expansion of the OVRO-LWA to 2.6 km baselines. These maps serve as a first step on the path to the use of more sophisticated foreground filters in 21-cm cosmology incorporating the measured angular and frequency structure of all foreground contaminants.Comment: 27 pages, 18 figure

    O- vs. N-protonation of 1-dimethylaminonaphthalene-8-ketones: formation of a peri N–C bond or a hydrogen bond to the pi-electron density of a carbonyl group

    Get PDF
    X-ray crystallography and solid-state NMR measurements show that protonation of a series of 1-dimethylaminonaphthalene-8-ketones leads either to O protonation with formation of a long N–C bond (1.637–1.669 Å) between peri groups, or to N protonation and formation of a hydrogen bond to the π surface of the carbonyl group, the latter occurring for the larger ketone groups (C(O)R, R = t-butyl and phenyl). Solid state 15N MAS NMR studies clearly differentiate the two series, with the former yielding significantly more deshielded resonances. This is accurately corroborated by DFT calculation of the relevant chemical shift parameters. In the parent ketones X-ray crystallography shows that the nitrogen lone pair is directed towards the carbonyl group in all cases

    Morning Increase in Onset of Ischemic Stroke

    Get PDF
    The Time of Onset of Ischemic Stroke Was Determined for 1,167 of 1,273 Patients during the Collection of Data by Four Academic Hospital Centers between June 30, 1983, and June 30, 1986. More Strokes Occurred in Awake Patients from 10:00 Am to Noon Than during Any Other 2-Hour Interval. the Incidence of Stroke Onset Declined Steadily during the Remainder of the Day and Early Evening. the Onset of Stroke is Least Likely to Occur in the Late Evening, Before Midnight. © 1989 American Heart Association, Inc

    Bcl-2 functionally interacts with inositol 1,4,5-trisphosphate receptors to regulate calcium release from the ER in response to inositol 1,4,5-trisphosphate

    Get PDF
    Inositol 1,4,5-trisphosphate (InsP3) receptors (InsP3Rs) are channels responsible for calcium release from the endoplasmic reticulum (ER). We show that the anti-apoptotic protein Bcl-2 (either wild type or selectively localized to the ER) significantly inhibited InsP3-mediated calcium release and elevation of cytosolic calcium in WEHI7.2 T cells. This inhibition was due to an effect of Bcl-2 at the level of InsP3Rs because responses to both anti-CD3 antibody and a cell-permeant InsP3 ester were decreased. Bcl-2 inhibited the extent of calcium release from the ER of permeabilized WEHI7.2 cells, even at saturating concentrations of InsP3, without decreasing luminal calcium concentration. Furthermore, Bcl-2 reduced the open probability of purified InsP3Rs reconstituted into lipid bilayers. Bcl-2 and InsP3Rs were detected together in macromolecular complexes by coimmunoprecipitation and blue native gel electrophoresis. We suggest that this functional interaction of Bcl-2 with InsP3Rs inhibits InsP3R activation and thereby regulates InsP3-induced calcium release from the ER
    • …
    corecore