106 research outputs found

    Segmentation and tracking of video objects for a content-based video indexing context

    Get PDF
    This paper examines the problem of segmentation and tracking of video objects for content-based information retrieval. Segmentation and tracking of video objects plays an important role in index creation and user request definition steps. The object is initially selected using a semi-automatic approach. For this purpose, a user-based selection is required to define roughly the object to be tracked. In this paper, we propose two different methods to allow an accurate contour definition from the user selection. The first one is based on an active contour model which progressively refines the selection by fitting the natural edges of the object while the second used a binary partition tree with aPeer ReviewedPostprint (published version

    Progress in Atomic Fountains at LNE-SYRTE

    Full text link
    We give an overview of the work done with the Laboratoire National de M\'etrologie et d'Essais-Syst\`emes de R\'ef\'erence Temps-Espace (LNE-SYRTE) fountain ensemble during the last five years. After a description of the clock ensemble, comprising three fountains, FO1, FO2, and FOM, and the newest developments, we review recent studies of several systematic frequency shifts. This includes the distributed cavity phase shift, which we evaluate for the FO1 and FOM fountains, applying the techniques of our recent work on FO2. We also report calculations of the microwave lensing frequency shift for the three fountains, review the status of the blackbody radiation shift, and summarize recent experimental work to control microwave leakage and spurious phase perturbations. We give current accuracy budgets. We also describe several applications in time and frequency metrology: fountain comparisons, calibrations of the international atomic time, secondary representation of the SI second based on the 87Rb hyperfine frequency, absolute measurements of optical frequencies, tests of the T2L2 satellite laser link, and review fundamental physics applications of the LNE-SYRTE fountain ensemble. Finally, we give a summary of the tests of the PHARAO cold atom space clock performed using the FOM transportable fountain.Comment: 19 pages, 12 figures, 5 tables, 126 reference

    Improved tests of Local Position Invariance using 87Rb and 133Cs fountains

    Full text link
    We report tests of local position invariance based on measurements of the ratio of the ground state hyperfine frequencies of 133Cs and 87Rb in laser-cooled atomic fountain clocks. Measurements extending over 14 years set a stringent limit to a possible variation with time of this ratio: d ln(nu_Rb/nu_Cs)/dt=(-1.39 +/- 0.91)x 10-16 yr-1. This improves by a factor of 7.7 over our previous report (H. Marion et al., Phys. Rev. Lett. 90, 150801 (2003)). Our measurements also set the first limit to a fractional variation of the Rb/Cs ratio with gravitational potential at the level of c^2 d ln(nu_Rb/nu_Cs)/dU=(0.11 +/- 1.04)x 10^-6, providing a new stringent differential redshift test. The above limits equivalently apply to the fractional variation of the quantity alpha^{-0.49}x(g_Rb/g_Cs), which involves the fine structure constant alpha and the ratio of the nuclear g-factors of the two alkalis. The link with variations of the light quark mass is also presented together with a global analysis combining with other available highly accurate clock comparisons.Comment: 5 pages, 3 figures, 3 tables, 34 reference

    A Search for Variations of Fundamental Constants using Atomic Fountain Clocks

    Get PDF
    Over five years we have compared the hyperfine frequencies of 133Cs and 87Rb atoms in their electronic ground state using several laser cooled 133Cs and 87Rb atomic fountains with an accuracy of ~10^{-15}. These measurements set a stringent upper bound to a possible fractional time variation of the ratio between the two frequencies : (d/dt)ln(nu_Rb/nu_Cs)=(0.2 +/- 7.0)*10^{-16} yr^{-1} (1 sigma uncertainty). The same limit applies to a possible variation of the quantity (mu_Rb/mu_Cs)*alpha^{-0.44}, which involves the ratio of nuclear magnetic moments and the fine structure constant.Comment: 4 pages, 3 figures, 1 table submitted to Phys. Rev. Let

    Ultra-low noise microwave generation with fiber-based optical frequency comb and application to atomic fountain clock

    Full text link
    We demonstrate the use of a fiber-based femtosecond laser locked onto an ultra-stable optical cavity to generate a low-noise microwave reference signal. Comparison with both a liquid Helium cryogenic sapphire oscillator (CSO) and a Ti:Sapphire-based optical frequency comb system exhibit a stability about 3×10153\times10^{-15} between 1 s and 10 s. The microwave signal from the fiber system is used to perform Ramsey spectroscopy in a state-of-the-art Cesium fountain clock. The resulting clock system is compared to the CSO and exhibits a stability of 3.5×1014τ1/23.5\times10^{-14}\tau^{-1/2}. Our continuously operated fiber-based system therefore demonstrates its potential to replace the CSO for atomic clocks with high stability in both the optical and microwave domain, most particularly for operational primary frequency standards.Comment: 3 pages, 3 figure

    Controlling the cold collision shift in high precision atomic interferometry

    Get PDF
    We present here a new method based on a transfer of population by adiabatic passage that allows to prepare cold atomic samples with a well defined ratio of atomic density and atom number. This method is used to perform a measurement of the cold collision frequency shift in a laser cooled cesium clock at the percent level, which makes the evaluation of the cesium fountains accuracy at the 101610^{-16} level realistic. With an improved set-up, the adiabatic passage would allow measurements of atom number-dependent phase shifts at the 10310^{-3} level in high precision experiments.Comment: 4 pages, 3 figures, 2 table

    Experimenting an optical second with strontium lattice clocks

    Full text link
    Progress in realizing the SI second had multiple technological impacts and enabled to further constraint theoretical models in fundamental physics. Caesium microwave fountains, realizing best the second according to its current definition with a relative uncertainty of 2-4x10^(-16), have already been superseded by atomic clocks referenced to an optical transition, both more stable and more accurate. Are we ready for a new definition of the second? Here we present an important step in this direction: our system of five clocks connects with an unprecedented consistency the optical and the microwave worlds. For the first time, two state-of-the-art strontium optical lattice clocks are proven to agree within their accuracy budget, with a total uncertainty of 1.6x10^(-16). Their comparison with three independent caesium fountains shows a degree of reproducibility henceforth solely limited at the level of 3.1x10^(-16) by the best realizations of the microwave-defined second.Comment: 9 pages, 4 figures, 2 table

    New Limits to the Drift of Fundamental Constants from Laboratory Measurements

    Get PDF
    We have remeasured the absolute 1S1S-2S2S transition frequency νH\nu_{\rm {H}} in atomic hydrogen. A comparison with the result of the previous measurement performed in 1999 sets a limit of (29±57)(-29\pm 57) Hz for the drift of νH\nu_{\rm {H}} with respect to the ground state hyperfine splitting νCs\nu_{{\rm {Cs}}} in 133^{133}Cs. Combining this result with the recently published optical transition frequency in 199^{199}Hg+^+ against νCs\nu_{\rm {Cs}} and a microwave 87^{87}Rb and 133^{133}Cs clock comparison, we deduce separate limits on α˙/α=(0.9±2.9)×1015\dot{\alpha}/\alpha = (-0.9\pm 2.9)\times 10^{-15} yr1^{-1} and the fractional time variation of the ratio of Rb and Cs nuclear magnetic moments μRb/μCs\mu_{\rm {Rb}}/\mu_{\rm {Cs}} equal to (0.5±1.7)×1015(-0.5 \pm 1.7)\times 10^{-15} yr1^{-1}. The latter provides information on the temporal behavior of the constant of strong interaction.Comment: 4 pages, 3 figures, LaTe

    Tests of relativity using a microwave resonator

    Get PDF
    The frequencies of a cryogenic sapphire oscillator and a hydrogen maser are compared to set new constraints on a possible violation of Lorentz invariance. We determine the variation of the oscillator frequency as a function of its orientation (Michelson-Morley test) and of its velocity (Kennedy-Thorndike test) with respect to a preferred frame candidate. We constrain the corresponding parameters of the Mansouri and Sexl test theory to δβ+1/2=(1.5±4.2)×109\delta - \beta + 1/2 = (1.5\pm 4.2) \times 10^{-9} and βα1=(3.1±6.9)×107\beta - \alpha - 1 = (-3.1\pm 6.9) \times 10^{-7} which is equivalent to the best previous result for the former and represents a 30 fold improvement for the latter.Comment: 8 pages, 2 figures, submitted to Physical Review Letters (October 3, 2002
    corecore