9 research outputs found

    A linear CO chemistry parameterization in a chemistry-transport model: evaluation and application to data assimilation

    Get PDF
    This paper presents an evaluation of a new linear parameterization valid for the troposphere and the stratosphere, based on a first order approximation of the carbon monoxide (CO) continuity equation. This linear scheme (hereinafter noted LINCO) has been implemented in the 3-D Chemical Transport Model (CTM) MOCAGE (MOdèle de Chimie Atmospherique Grande Echelle). First, a one and a half years of LINCO simulation has been compared to output obtained from a detailed chemical scheme output. The mean differences between both schemes are about ±25 ppbv (part per billion by volume) or 15% in the troposphere and ±10 ppbv or 100% in the stratosphere. Second, LINCO has been compared to diverse observations from satellite instruments covering the troposphere (Measurements Of Pollution In The Troposphere: MOPITT) and the stratosphere (Microwave Limb Sounder: MLS) and also from aircraft (Measurements of ozone and water vapour by Airbus in-service aircraft: MOZAIC programme) mostly flying in the upper troposphere and lower stratosphere (UTLS). In the troposphere, the LINCO seasonal variations as well as the vertical and horizontal distributions are quite close to MOPITT CO observations. However, a bias of ~−40 ppbv is observed at 700 Pa between LINCO and MOPITT. In the stratosphere, MLS and LINCO present similar large-scale patterns, except over the poles where the CO concentration is underestimated by the model. In the UTLS, LINCO presents small biases less than 2% compared to independent MOZAIC profiles. Third, we assimilated MOPITT CO using a variational 3D-FGAT (First Guess at Appropriate Time) method in conjunction with MOCAGE for a long run of one and a half years. The data assimilation greatly improves the vertical CO distribution in the troposphere from 700 to 350 hPa compared to independent MOZAIC profiles. At 146 hPa, the assimilated CO distribution is also improved compared to MLS observations by reducing the bias up to a factor of 2 in the tropics. This study confirms that the linear scheme is able to simulate reasonably well the CO distribution in the troposphere and in the lower stratosphere. Therefore, the low computing cost of the linear scheme opens new perspectives to make free runs and CO data assimilation runs at high resolution and over periods of several years

    Midlatitude stratosphere - troposphere exchange as diagnosed by MLS O3 and MOPITT CO assimilated fields

    Get PDF
    International audienceThis paper presents a comprehensive characterization of a very deep stratospheric intrusion which occurred over the British Isles on 15 August 2007. The signature of this event is diagnosed using ozonesonde measurements over Lerwick, UK (60.14 N, 1.19 W) and is also well characterized using meteorological analyses from the global operational weather prediction model of Météo-France, ARPEGE. Modelled as well as assimilated fields of both ozone (O3) and carbon monoxide (CO) have been used in order to better document this event. O3 and CO from Aura/MLS and Terra/MOPITT instruments, respectively, are assimilated into the three-dimensional chemical transport model MOCAGE of Météo-France using a variational 3-DFGAT (First Guess at Appropriate Time) method. The validation of O3 and CO assimilated fields is done using selfconsistency diagnostics and by comparison with independent observations such as MOZAIC (O3 and CO), AIRS (CO) and OMI (O3). It particularly shows in the upper troposphere and lower stratosphere region that the assimilated fields are closer to MOZAIC than the free model run. The O3 bias between MOZAIC and the analyses is −11.5 ppbv with a RMS of 22.4 ppbv and a correlation coefficient of 0.93, whereas between MOZAIC and the free model run, the corresponding values are 33 ppbv, 38.5 ppbv and 0.83, respectively. In the same way, for CO, the bias, RMS and correlation coefficient between MOZAIC and the analyses are −3.16 ppbv, 13 ppbv and 0.79, respectively, whereas between MOZAIC and the free model run, the corresponding values are 33 ppbv, 38.5 ppbv and 0.83, respectively. In the same way, for CO, the bias, RMS and correlation coefficient between MOZAIC and the analyses are −3.16 ppbv, 13 ppbv and 0.79, respectively, whereas between MOZAIC and the free model they are 6.3 ppbv, 16.6 ppbv and 0.71, respectively. The paper also presents a demonstration of the capability of O3 and CO assimilated fields to better describe a stratosphere-troposphere exchange (STE) event in comparison with the free run modelled O3 and CO fields. Although the assimilation of MLS data improves the distribution of O3 above the tropopause compared to the free model run, it is not sufficient to reproduce the STE event well. Assimilated MOPITT CO allows a better qualitative description of the stratospheric intrusion event. The MOPITT CO analyses appear more promising than the MLS O3 analyses in terms of their ability to capture a deep STE event. Therefore, the results of this study open the perspectives for using MOPITT CO in the STE studies

    A geostationary thermal infrared sensor to monitor the lowermost troposphere: O₃ and CO retrieval studies

    Get PDF
    This paper describes the capabilities of a nadir thermal infrared (TIR) sensor proposed for deployment onboard a geostationary platform to monitor ozone (O3) and carbon monoxide (CO) for air quality (AQ) purposes. To assess the capabilities of this sensor we perform idealized retrieval studies considering typical atmospheric profiles of O3 and CO over Europe with different instrument configuration (signal to noise ratio, SNR, and spectral sampling interval, SSI) using the KOPRA forward model and the KOPRA-fit retrieval scheme. We then select a configuration, referred to as GEO-TIR, optimized for providing information in the lowermost troposphere (LmT; 0–3 km in height). For the GEO-TIR configuration we obtain ~1.5 degrees of freedom for O3 and ~2 for CO at altitudes between 0 and 15 km. The error budget of GEO-TIR, calculated using the principal contributions to the error (namely, temperature, measurement error, smoothing error) shows that information in the LmT can be achieved by GEO-TIR. We also retrieve analogous profiles from another geostationary infrared instrument with SNR and SSI similar to the Meteosat Third Generation Infrared Sounder (MTG-IRS) which is dedicated to numerical weather prediction, referred to as GEO-TIR2. We quantify the added value of GEO-TIR over GEO-TIR2 for a realistic atmosphere, simulated using the chemistry transport model MOCAGE (MOd`ele de Chimie Atmospherique `a Grande Echelle). Results show that GEO-TIR is able to capture well the spatial and temporal variability in the LmT for both O3 and CO. These results also provide evidence of the significant added value in the LmT of GEO-TIR compared to GEO-TIR2 by showing GEO-TIR is closer to MOCAGE than GEO-TIR2 for various statistical parameters (correlation, bias, standard deviation)

    Stratosphere-troposphere ozone exchange from high resolution MLS ozone analyses

    Get PDF
    We assimilate stratospheric ozone profiles from MLS (Microwave Limb Sounder) into the MOCAGE Chemistry Transport Model (CTM) to study Stratosphere-Troposphere Exchange (STE). This study uses two horizontal grid resolutions of 2° and 0.2°. The combined impacts of MLS ozone assimilation and high horizontal resolution are illustrated in two case studies where STE events occurred (23 June 2009 and 17 July 2009). At high resolution the filamentary structures of stratospheric air which characterise STE events are captured by the model. To test the impact of the assimilation and the resolution, we compare model outputs from different experiments (high resolution and low resolution; MLS assimilation run and free run) with independent data (MOZAIC aircraft ozone data; WOUDC ozone sonde network data). MLS ozone analyses show a better description of the Upper Troposphere Lower Stratosphere (UTLS) region and the stratospheric intrusions than the free model run. In particular, at high horizontal resolution the MLS ozone analyses present realistic filamentary ozone structures in the UTLS and laminae structures in the ozone profile. Despite a low aspect ratio between horizontal resolution and vertical resolution in the UTLS at high horizontal resolution, MLS ozone analyses improve the vertical structures of the ozone fields. Results from backward trajectories and ozone forecasts show that assimilation at high horizontal resolution of MLS ozone profiles between 10 hPa and 215 hPa has an impact on tropospheric ozone

    Monitoring Air Quality from Space: The Case for the Geostationary Platform

    No full text
    International audienceAir quality (AQ) is defined by the atmospheric composition of gases and particulates near the Earth's surface. This composition depends on local emissions of pollutants, chemistry, and transport processes; it is highly variable in space and time. Key lower-tropospheric pollutants include ozone, aerosols, and the ozone precursors NOx and volatile organic compounds. Information on the transport of pollutants is provided by carbon monoxide measurements. Air quality impacts human society, because high concentrations of pollutants can have adverse effects on human health; health costs attributable to AQ are high. The ability to monitor, forecast, and manage AQ is thus crucial for human society. In this paper we identify the observational requirements needed to undertake this task, discuss the advantages of the geostationary platform for monitoring AQ from space, and indicate important challenges to overcome. We present planned geostationary missions to monitor AQ in Europe, the United States, and Asia, and advocate for the usefulness of such a constellation in addition to the current global observing system of tropospheric comp

    A thermal infrared instrument onboard a geostationary platform for CO and O-3 measurements in the lowermost troposphere: Observing System Simulation Experiments (OSSE)

    No full text
    International audienceThis paper presents observing system simulation experiments (OSSEs) to compare the relative capabilities of two geostationary thermal infrared (TIR) instruments to monitor ozone (O3) and carbon monoxide (CO) for air quality (AQ) purposes over Europe. The originality of this study is to use OSSEs to assess how these infrared instruments can constrain different errors affecting AQ hindcasts and forecasts (emissions, meteorology, initial condition and the 3 parameters together). The first instrument (GEO-TIR) has a configuration optimized to monitor O3 and CO in the lowermost tr posphere (LmT; defined to be the atmosphere between the surface and 3 km), and the second instrument (GEO-TIR2) is designed to monitor temperature and humidity. Both instruments measure radiances in the same spectral TIR band. Results show that GEO-TIR could have a significant impact (GEO-TIR is closer to the reference atmosphere than GEO-TIR2) on the analyses of O3 and CO LmT column. The value of the measurements for both instruments is mainly over the Mediterranean Basin and some impact can be found over the Atlantic Ocean and Northern Europe. The impact of GEO-TIR is mainly above 1 km for O3 and CO but can also improve the surface analyses for CO. The analyses of GEO-TIR2 show low impact for O3 LmT column but a significant impact (but lower than for GEO-TIR) for CO above 1 km. The results of this study indicate the beneficial impact from an infrared instrument (GEO-TIR) dedicated to monitoring O3 and CO concentrations in the LmT, and quantify the value of this information for constraining AQ models

    Midlatitude stratosphere &ndash; troposphere exchange as diagnosed by MLS O<sub>3</sub> and MOPITT CO assimilated fields

    No full text
    This paper presents a comprehensive characterization of a very deep stratospheric intrusion which occurred over the British Isles on 15 August 2007. The signature of this event is diagnosed using ozonesonde measurements over Lerwick, UK (60.14&deg; N, 1.19&deg; W) and is also well characterized using meteorological analyses from the global operational weather prediction model of Météo-France, ARPEGE. Modelled as well as assimilated fields of both ozone (O3) and carbon monoxide (CO) have been used in order to better document this event. O3 and CO from Aura/MLS and Terra/MOPITT instruments, respectively, are assimilated into the three-dimensional chemical transport model MOCAGE of Météo-France using a variational 3-D-FGAT (First Guess at Appropriate Time) method. The validation of O3 and CO assimilated fields is done using self-consistency diagnostics and by comparison with independent observations such as MOZAIC (O3 and CO), AIRS (CO) and OMI (O3). It particularly shows in the upper troposphere and lower stratosphere region that the assimilated fields are closer to MOZAIC than the free model run. The O3 bias between MOZAIC and the analyses is &minus;11.5 ppbv with a RMS of 22.4 ppbv and a correlation coefficient of 0.93, whereas between MOZAIC and the free model run, the corresponding values are 33 ppbv, 38.5 ppbv and 0.83, respectively. In the same way, for CO, the bias, RMS and correlation coefficient between MOZAIC and the analyses are &minus;3.16 ppbv, 13 ppbv and 0.79, respectively, whereas between MOZAIC and the free model they are 6.3 ppbv, 16.6 ppbv and 0.71, respectively. The paper also presents a demonstration of the capability of O3 and CO assimilated fields to better describe a stratosphere-troposphere exchange (STE) event in comparison with the free run modelled O3 and CO fields. Although the assimilation of MLS data improves the distribution of O3 above the tropopause compared to the free model run, it is not sufficient to reproduce the STE event well. Assimilated MOPITT CO allows a better qualitative description of the stratospheric intrusion event. The MOPITT CO analyses appear more promising than the MLS O3 analyses in terms of their ability to capture a deep STE event. Therefore, the results of this study open the perspectives for using MOPITT CO in the STE studies

    A geostationary thermal infrared sensor to monitor the lowermost troposphere: O3 and CO retrieval studies

    No full text
    International audienceThis paper describes the capabilities of a nadir thermal infrared (TIR) sensor proposed for deployment onboard a geostationary platform to monitor ozone (O3) and carbon monoxide (CO) for air quality (AQ) purposes. To assess the capabilities of this sensor we perform idealized retrieval studies considering typical atmospheric profiles of O3 and CO over Europe with different instrument configuration (signal to noise ratio, SNR, and spectral sampling interval, SSI) using the KOPRA forward model and the KOPRA-fit retrieval scheme. We then select a configuration, referred to as GEO-TIR, optimized for providing information in the lowermost troposphere (LmT; 0-3 km in height). For the GEO-TIR configuration we obtain ~1.5 degrees of freedom for O3 and ~2 for CO at altitudes between 0 and 15 km. The error budget of GEO-TIR, calculated using the principal contributions to the error (namely, temperature, measurement error, smoothing error) shows that information in the LmT can be achieved by GEO-TIR. We also retrieve analogous profiles from another geostationary infrared instrument with SNR and SSI similar to the Meteosat Third Generation Infrared Sounder (MTG-IRS) which is dedicated to numerical weather prediction, referred to as GEO-TIR2. We quantify the added value of GEO-TIR over GEO-TIR2 for a realistic atmosphere, simulated using the chemistry transport model MOCAGE (MOdèle de Chimie Atmospherique à Grande Echelle). Results show that GEO-TIR is able to capture well the spatial and temporal variability in the LmT for both O3 and CO. These results also provide evidence of the significant added value in the LmT of GEO-TIR compared to GEO-TIR2 by showing GEO-TIR is closer to MOCAGE than GEO-TIR2 for various statistical parameters (correlation, bias, standard deviation)
    corecore