35 research outputs found
Recommended from our members
Improved Spatial Resolution in Thick, Fully-Depleted CCDs withEnhanced Red Sensitivity
The point spread function (PSF) is an important measure of spatial resolution in CCDs for point-like objects, since it affects image quality and spectroscopic resolution. We present new data and theoretical developments for lateral charge diffusion in thick, fully-depleted charge-coupled devices (CCDs) developed at Lawrence Berkeley National Laboratory (LBNL). Because they can be over-depleted, the LBNL devices have no field-free region and diffusion is controlled through the application of an external bias voltage. We give results for a 3512 x 3512 format, 10.5 {micro}m pixel back-illuminated p-channel CCD developed for the SuperNova/Acceleration Probe (SNAP), a proposed satellite-based experiment designed to study dark energy. The PSF was measured at substrate bias voltages between 3 V and 115 V. At a bias voltage of 115 V, we measure an rms diffusion of 3.7 {+-} 0.2 {micro}m. Lateral charge diffusion in LBNL CCDs will meet the SNAP requirements
Recommended from our members
Astro2020 APC White Paper: The MegaMapper: a z > 2 spectroscopic instrument for the study of Inflation and Dark Energy
MegaMapper is a proposed ground-based experiment to measure Inflation
parameters and Dark Energy from galaxy redshifts at
GWAS meta-analysis of over 29,000 people with epilepsy identifies 26 risk loci and subtype-specific genetic architecture
Epilepsy is a highly heritable disorder affecting over 50 million people worldwide, of which about one-third are resistant to current treatments. Here we report a multi-ancestry genome-wide association study including 29,944 cases, stratified into three broad categories and seven subtypes of epilepsy, and 52,538 controls. We identify 26 genome-wide significant loci, 19 of which are specific to genetic generalized epilepsy (GGE). We implicate 29 likely causal genes underlying these 26 loci. SNP-based heritability analyses show that common variants explain between 39.6% and 90% of genetic risk for GGE and its subtypes. Subtype analysis revealed markedly different genetic architectures between focal and generalized epilepsies. Gene-set analyses of GGE signals implicate synaptic processes in both excitatory and inhibitory neurons in the brain. Prioritized candidate genes overlap with monogenic epilepsy genes and with targets of current antiseizure medications. Finally, we leverage our results to identify alternate drugs with predicted efficacy if repurposed for epilepsy treatment
CMB-S4
We describe the stage 4 cosmic microwave background ground-based experiment CMB-S4
Recommended from our members
Measurement of lateral charge diffusion in thick, fully depleted, back-illuminated CCDs
Lateral charge diffusion in back-illuminated CCDs directly affects the point spread function (PSF) and spatial resolution of an imaging device. This can be of particular concern in thick, back-illuminated CCDs. We describe a technique of measuring this diffusion and present PSF measurements for an 800x1100, 15 mu m pixel, 280 mu m thick, back-illuminated, p-channel CCD that can be over-depleted. The PSF is measured over a wavelength range of 450 nm to 650 nm and at substrate bias voltages between 6 V and 80 V
Recommended from our members
Quantum efficiency characterization of LBNL CCD's Part 1: the Quantum Efficiency Machine
Instrumentation was developed in 2004 and 2005 to measure the quantum efficiency of the Lawrence Berkeley National Lab (LBNL)total-depletion CCD's, intended for astronomy and space applications. This paper describes the basic instrument. Although it is conventional even to the parts list, there are important innovations. A xenon arc light source was chosen for its high blue/UV and low red/IR output as compared with a tungsten light. Intensity stabilization has been difficult, but sinceonly flux ratios matter this is not critical. Between the light source andan Oriel MS257 monochromator are a shutter and two filter wheels. High-bandpass and low-bandpass filter pairs isolate the 150-nm wide bands appropriate to the wavelength, thus minimizing scattered light and providing order blocking. Light from the auxiliary port enters a 20-inch optical sphere, and the 4-inch output port is at right angles to the input port. An 80 cm drift space produces near-uniform illumination on the CCD. Next to the cold CCD inside the horizontal dewar is a calibrated reference photodiode which is regulated to the PD calibration temperature, 25 C. The ratio ofthe CCD and in-dewar reference PD signals provides the QE measurement. Additional cross-calibration to a PD on the integrating sphere permitslower-intensity exposures
Recommended from our members
Improved Spatial Resolution in Thick, Fully-Depleted CCDs with Enhanced Red Sensitivity
A 260 megapixel visible/NIR mixed technology focal plane for space
ABSTRACT Mission concepts for NASA's Wide Field Infrared Survey Telescope (WFIRST