9 research outputs found

    Functionality and Cell Senescence of CD4/ CD8-Selected CD20 CAR T Cells Manufactured Using the Automated CliniMACS Prodigy® Platform

    Get PDF
    Clinical studies using autologous CAR T cells have achieved spectacular remissions in refractory CD19+ B cell leukaemia, however some of the patient treatments with CAR T cells failed. Beside the heterogeneity of leukaemia, the distribution and senescence of the autologous cells from heavily pretreated patients might be further reasons for this. We performed six consecutive large-scale manufacturing processes for CD20 CAR T cells from healthy donor leukapheresis using the automated CliniMACS Prodigy® platform. Starting with a CD4/CD8-positive selection, a high purity of a median of 97% T cells with a median 65-fold cell expansion was achieved. Interestingly, the transduction rate was significantly higher for CD4+ compared to CD8+ T cells and reached in a median of 23%. CD20 CAR T cells showed a good specific IFN-γ secretion after cocultivation with CD20+ target cells which correlated with good cytotoxic activity. Most importantly, 3 out of 5 CAR T cell products showed an increase in telomere length during the manufacturing process, while telomere length remained consistent in one and decreased in another process. In conclusion, this shows for the first time that beside heterogeneity among healthy donors, CAR T cell products also differ regarding cell senescence, even for cells manufactured in a standardised automated process

    Comparative analysis of clinical-scale IFN-gamma positive T-cell enrichment using partially and fully integrated platforms

    Get PDF
    Background and aims. The infusion of enriched CMV-specific donor T-cells appears to be a suitable alternative for the treatment of drug resistant CMV reactivation or de novo infection after both solid organ and hematopoietic stem cell transplantation. Antiviral lymphocytes can be selected from apheresis products using the CliniMACS Cytokine-Capture-System® either with the well-established CliniMACS® Plus (Plus) device or with its more versatile successor CliniMACS Prodigy® (Prodigy). Methods. Manufacturing of CMV-specific T-cells was carried out with the Prodigy and Plus in parallel starting with 0.8-1*109 leukocytes collected by lymphapheresis (n=3) and using the MACS GMP PepTivator® HCMVpp65 for antigenic re-stimulation. Target and non-target cells were quantified by a newly developed single-platform assessment and gating strategy using positive (CD3/CD4/CD8/CD45/IFN-gamma), negative (CD14/CD19/CD56), and dead cell (7-AAD) discriminators. Results. Both devices produced largely similar results for target cell viabilities: 37.2%-52.2% (Prodigy) vs. 51.1%-62.1% (Plus) CD45+/7-AAD- cells. Absolute numbers of isolated target cells were 0.1-3.8*106 viable IFN-gamma+ CD3+ cells. The corresponding proportions of IFN-gamma+ CD3+ cells ranged between 19.2% and 95.1% among total CD3+ cells and represented recoveries of 41.9%-87.6%. Within two parallel processes predominantly IFN-gamma+ CD3+CD8+ cytotoxic T-cells were enriched compared to one process that yielded a higher amount of IFN-gamma+ CD3+CD4+ helper T lymphocytes. T-cell purity was higher for the Prodigies products that displayed a lower content of contaminating IFN-gamma- T-cells (3.6%-20.8%) compared to the Plus products (19.9%-80.0%). Conclusions. The manufacturing process on the Prodigy saved both process and hands-on time due to its higher process integration and ability for unattended operation. Although the usage of both instruments yielded comparable results, the lower content of residual IFN-gamma- T-cells in the target fractions produced with the Prodigy may allow for a higher dosage of CMV-specific donor T-cells without increasing the risk for graft versus host disease

    Functionality and Cell Senescence of CD4/ CD8-Selected CD20 CAR T Cells Manufactured Using the Automated CliniMACS Prodigy® Platform

    No full text
    Clinical studies using autologous CAR T cells have achieved spectacular remissions in refractory CD19+ B cell leukaemia, however some of the patient treatments with CAR T cells failed. Beside the heterogeneity of leukaemia, the distribution and senescence of the autologous cells from heavily pretreated patients might be further reasons for this. We performed six consecutive large-scale manufacturing processes for CD20 CAR T cells from healthy donor leukapheresis using the automated CliniMACS Prodigy (R) platform. Starting with a CD4/CD8-positive selection, a high purity of a median of 97% T cells with a median 65-fold cell expansion was achieved. Interestingly, the transduction rate was significantly higher for CD4+compared to CD8+ T cells and reached in a median of 23%. CD20 CAR T cells showed a good specific IFN-gamma secretion after cocultivation with CD20+ target cells which correlated with good cytotoxic activity. Most importantly, 3 out of 5 CAR T cell products showed an increase in telomere length during the manufacturing process, while telomere length remained consistent in one and decreased in another process. In conclusion, this shows for the first time that beside heterogeneity among healthy donors, CAR T cell products also differ regarding cell senescence, even for cells manufactured in a standardised automated process. (C) 2019 S. Karger AG, Base

    Functionality and Cell Senescence of CD4/ CD8-Selected CD20 CAR T Cells Manufactured Using the Automated CliniMACS Prodigy® Platform

    Get PDF
    Clinical studies using autologous CAR T cells have achieved spectacular remissions in refractory CD19+ B cell leukaemia, however some of the patient treatments with CAR T cells failed. Beside the heterogeneity of leukaemia, the distribution and senescence of the autologous cells from heavily pretreated patients might be further reasons for this. We performed six consecutive large-scale manufacturing processes for CD20 CAR T cells from healthy donor leukapheresis using the automated CliniMACS Prodigy® platform. Starting with a CD4/CD8-positive selection, a high purity of a median of 97% T cells with a median 65-fold cell expansion was achieved. Interestingly, the transduction rate was significantly higher for CD4+ compared to CD8+ T cells and reached in a median of 23%. CD20 CAR T cells showed a good specific IFN-γ secretion after cocultivation with CD20+ target cells which correlated with good cytotoxic activity. Most importantly, 3 out of 5 CAR T cell products showed an increase in telomere length during the manufacturing process, while telomere length remained consistent in one and decreased in another process. In conclusion, this shows for the first time that beside heterogeneity among healthy donors, CAR T cell products also differ regarding cell senescence, even for cells manufactured in a standardised automated process

    Functionality and Cell Senescence of CD4/ CD8-Selected CD20 CAR T Cells Manufactured Using the Automated CliniMACS Prodigy® Platform

    No full text
    Clinical studies using autologous CAR T cells have achieved spectacular remissions in refractory CD19+ B cell leukaemia, however some of the patient treatments with CAR T cells failed. Beside the heterogeneity of leukaemia, the distribution and senescence of the autologous cells from heavily pretreated patients might be further reasons for this. We performed six consecutive large-scale manufacturing processes for CD20 CAR T cells from healthy donor leukapheresis using the automated CliniMACS Prodigy® platform. Starting with a CD4/CD8-positive selection, a high purity of a median of 97% T cells with a median 65-fold cell expansion was achieved. Interestingly, the transduction rate was significantly higher for CD4+ compared to CD8+ T cells and reached in a median of 23%. CD20 CAR T cells showed a good specific IFN-γ secretion after cocultivation with CD20+ target cells which correlated with good cytotoxic activity. Most importantly, 3 out of 5 CAR T cell products showed an increase in telomere length during the manufacturing process, while telomere length remained consistent in one and decreased in another process. In conclusion, this shows for the first time that beside heterogeneity among healthy donors, CAR T cell products also differ regarding cell senescence, even for cells manufactured in a standardised automated process

    Plasma interferon-gamma-inducible protein 10 (IP-10) levels correlate with disease severity and paradoxical reactions in extrapulmonary tuberculosis

    No full text
    Background With 1.5 million deaths worldwide in 2018, tuberculosis (TB) remains a major global public health problem. While pulmonary TB (PTB) is the most common manifestation, the proportion of extrapulmonary TB (EPTB) is increasing in low-burden countries. EPTB is a heterogeneous disease entity posing diagnostic and management challenges due to the lack of reliable biomarkers. In this study, we prospectively evaluated clinical data and treatment response which were correlated with different biomarkers. Methods The study was conducted at the University Hospital of Cologne. 20 patients with EPTB were enrolled. We analyzed plasma interferon-gamma-inducible protein 10 (IP-10) levels in plasma by ELISA for up to 12 months of treatment. In addition, the QuantiFERON(R)-TB Gold Plus (QFT(R) Plus) test was performed during the course of treatment. Clinical data were assessed prospectively and correlated with QFT(R) Plus and IP-10 levels. Results Plasma IP-10 levels were found to be significantly increased (p < 0.001) in patients with extensive disease compared to patients with limited disease (cervical lymph node TB) or healthy controls. In patients with clinically confirmed paradoxical reaction (PR), a further increase of IP-10 was noted. IFN-gamma measured by the QFT(R) Plus test did not decrease significantly during the course of treatment. Of note, in four EPTB patients (20%) without radiographic pulmonary involvement, sputum culture was positive for Mycobacterium tuberculosis. Conclusion Our data demonstrate that IP-10 may be a valuable biomarker for estimation of disease severity in EPTB and monitoring of the disease course in extensive forms. However, IP-10 may be less suitable for diagnosis and monitoring of EPTB patients with limited disease. The QFT(R) Plus test does not appear to be a suitable marker for therapy monitoring. Sputum should be examined in EPTB patients even in case of normal diagnostic imaging of the chest
    corecore