101 research outputs found

    There is variability in the attainment of developmental milestones in the CDKL5 disorder

    Get PDF
    Background: Individuals with the CDKL5 disorder have been described as having severely impaired development. A few individuals have been reported having attained more milestones including walking and running. Our aim was to investigate variation in attainment of developmental milestones and associations with underlying genotype. Methods: Data was sourced from the International CDKL5 Disorder Database, and individuals were included if they had a pathogenic or probably pathogenic CDKL5 mutation and information on early development. Kaplan-Meier time-to-event analyses investigated the occurrence of developmental milestones. Mutations were grouped by their structural/functional consequence, and Cox regression was used to investigate the relationship between genotype and milestone attainment. Results: The study included 109 females and 18 males. By 5 years of age, only 75% of the females had attained independent sitting and 25% independent walking whilst a quarter of the males could sit independently by 1 year 3 months. Only one boy could walk independently. No clear relationship between mutation group and milestone attainment was present, although females with a late truncating mutation attained the most milestones. Conclusion: Attainment of developmental milestones is severely impaired in the CDKL5 disorder, with the majority who did attain skills attaining them at a late age. It appears as though males are more severely impaired than the females. Larger studies are needed to further investigate the role of genotype on clinical variability

    Genomic testing for children with interstitial and diffuse lung disease (chILD): Parent satisfaction, understanding and health-related quality of life

    Get PDF
    Objective Research is needed to determine best practice for genomic testing in the context of child interstitial or diffuse lung disease (chILD). We explored parent’s and child’s health-related quality of life (HRQoL), parents’ perceived understanding of a genomic testing study, satisfaction with information and the study and decisional regret to undertake genomic testing. Methods Parents of children with diagnosed or suspected chILD who were enrolled in a genomic sequencing study were invited to complete questionnaires pretesting (T1) and after receiving the result (T2). Results Parents’ (T1, n=19; T2, n=17) HRQoL was lower than population norms. Study satisfaction (T1) and perceived understanding (T2) were positively correlated (rs=0.68, p=0.014). Satisfaction with information (T1 and T2) and decisional regret (T2) were negatively correlated (T1 rs=−0.71, p=0.01; T2 rs=−0.56, p=0.03). Parents reported wanting more frequent communication with staff throughout the genomic sequencing study, and greater information about the confidentiality of test results. Conclusions Understanding of genomic testing, satisfaction with information and participation and decisional regret are inter-related. Pretest consultations are important and can allow researchers to explain confidentiality of data and the variable turnaround times for receiving a test result. Staff can also update parents when there will be delays to receiving a result.Lauren Kelada, Claire Wakefield, Nada Vidic, David S Armstrong, Bruce Bennetts, Kirsten Boggs, John Christodoulou, Joanne Harrison, Gladys Ho, Nitin Kapur, Suzanna Lindsey-Temple, Tim McDonald, David Mowat, AndrĂ© Schultz, Hiran Selvadurai, Andrew Tai, Adam Jaff

    The CDKL5 disorder is an independent clinical entity associated with early-onset encephalopathy

    Get PDF
    The clinical understanding of the CDKL5 disorder remains limited, with most information being derived from small patient groups seen at individual centres. This study uses a large international data collection to describe the clinical profile of the CDKL5 disorder and compare with Rett syndrome (RTT). Information on individuals with cyclin-dependent kinase-like 5 (CDKL5) mutations (n=86) and females with MECP2 mutations (n=920) was sourced from the InterRett database. Available photographs of CDKL5 patients were examined for dysmorphic features. The proportion of CDKL5 patients meeting the recent Neul criteria for atypical RTT was determined. Logistic regression and time-to-event analyses were used to compare the occurrence of Rett-like features in those with MECP2 and CDKL5 mutations. Most individuals with CDKL5 mutations had severe developmental delay from birth, seizure onset before the age of 3 months and similar non-dysmorphic features. Less than one-quarter met the criteria for early-onset seizure variant RTT. Seizures and sleep disturbances were more common than in those with MECP2 mutations whereas features of regression and spinal curvature were less common. The CDKL5 disorder presents with a distinct clinical profile and a subtle facial, limb and hand phenotype that may assist in differentiation from other early-onset encephalopathies. Although mutations in the CDKL5 gene have been described in association with the early-onset variant of RTT, in our study the majority did not meet these criteria. Therefore, the CDKL5 disorder should be considered separate to RTT, rather than another variant

    Proceedings of the International Cancer Imaging Society (ICIS) 16th Annual Teaching Course

    Full text link
    Table of contents O1 Tumour heterogeneity: what does it mean? Dow-Mu Koh O2 Skeletal sequelae in adult survivors of childhood cancer Sue Creviston Kaste O3 Locoregional effects of breast cancer treatment Sarah J Vinnicombe O4 Imaging of cancer therapy-induced CNS toxicity Giovanni Morana, Andrea Rossi O5 Screening for lung cancer Christian J. Herold O6Risk stratification of lung nodules Theresa C. McLoud O7 PET imaging of pulmonary nodules Kirk A Frey O8 Transarterial tumour therapy Bernhard Gebauer O9 Interventional radiology in paediatric oncology Derek Roebuck O10 Image guided prostate interventions Jurgen J. FĂŒtterer O11 Imaging cancer predisposition syndromes Alexander J. Towbin O12Chest and chest wall masses Thierry AG Huisman O13 Abdominal masses: good or bad? Anne MJB Smets O14 Hepatobiliary MR contrast: enhanced liver MRI for HCC diagnosis and management Giovanni Morana O15 Role of US elastography and multimodality fusion for managing patients with chronic liver disease and HCC Jeong Min Lee O16 Opportunities and challenges in imaging metastatic disease Hersh Chandarana O17 Diagnosis, treatment monitoring, and follow-up of lymphoma Marius E. Mayerhoefer, Markus Raderer, Alexander Haug O18 Managing high-risk and advanced prostate cancer Matthias Eiber O19 Immunotherapy: imaging challenges Bernhard Gebauer O20 RECIST and RECIST 1.1 Andrea Rockall O21 Challenges of RECIST in oncology imaging basics for the trainee and novice Aslam Sohaib O22 Lymphoma: PET for interim and end of treatment response assessment: a users’ guide to the Deauville Score Victoria S Warbey O23 Available resources Hebert Alberto Vargas O24 ICIS e-portal and the online learning community Dow-Mu Koh O25 Benign lesions that mimic pancreatic cancer Jay P Heiken O26 Staging and reporting pancreatic malignancies Isaac R Francis, Mahmoud, M Al-Hawary, Ravi K Kaza O27 Intraductal papillary mucinous neoplasm Giovanni Morana O28 Cystic pancreatic tumours Mirko D’Onofrio O29 Diffusion-weighted imaging of head and neck tumours Harriet C. Thoeny O30 Radiation injury in the head and neck Ann D King O31 PET/MR of paediatric brain tumours Giovanni Morana, Arnoldo Piccardo, Maria Luisa GarrĂš, Andrea Rossi O32 Structured reporting and beyond Hebert Alberto Vargas O33 Massachusetts General Hospital experience with structured reporting Theresa C. McLoud O34 The oncologist’s perspective: what the oncologist needs to know Nick Reed O35 Towards the cure of all children with cancer: global initiatives in pediatric oncology Carlos Rodriguez-Galindo O36 Multiparametric imaging of renal cancers Hersh Chandarana O37 Linking imaging features of renal disease and their impact on management strategies Hebert Alberto Vargas O38 Adrenals, retroperitoneum and peritoneum Isaac R Francis, Ashish P Wasnik O39 Lung and pleura Stefan Diederich O40 Advances in MRI Jurgen J. FĂŒtterer O41 Advances in molecular imaging Wim J.G. Oyen O42 Incorporating advanced imaging, impact on treatment selection and patient outcome Cheng Lee Chaw, Nicholas van As S1 Combining ADC-histogram features improves performance of MR diffusion-weighted imaging for Lymph node characterisation in cervical cancer Igor Vieira, Frederik De Keyzer, Elleke Dresen, Sileny Han, Ignace Vergote, Philippe Moerman, Frederic Amant, Michel Koole, Vincent Vandecaveye S2 Whole-body diffusion-weighted MRI for surgical planning in patients with colorectal cancer and peritoneal metastases R Dresen, S De Vuysere, F De Keyzer, E Van Cutsem, A D’Hoore, A Wolthuis, V Vandecaveye S3 Role of apparent diffusion coefficient (ADC) diffusion-weighted MRI for predicting extra capsular extension of prostate cancer. P. Pricolo ([email protected]), S. Alessi, P. Summers, E. Tagliabue, G. Petralia S4 Generating evidence for clinical benefit of PET/CT – are management studies sufficient as surrogate for patient outcome? C. Pfannenberg, B. GĂŒckel, SC SchĂŒle, AC MĂŒller, S. Kaufmann, N. Schwenzer, M. Reimold,C. la Fougere, K. Nikolaou, P. Martus S5 Heterogeneity of treatment response in skeletal metastases from breast cancer with 18F-fluoride and 18F-FDG PET GJ Cook, GK Azad, BP Taylor, M Siddique, J John, J Mansi, M Harries, V Goh S6 Accuracy of suspicious breast imaging—can we tell the patient? S Seth, R Burgul, A Seth S7 Measurement method of tumour volume changes during neoadjuvant chemotherapy affects ability to predict pathological response S Waugh, N Muhammad Gowdh, C Purdie, A Evans, E Crowe, A Thompson, S Vinnicombe S8 Diagnostic yield of CT IVU in haematuria screening F. Arfeen, T. Campion, E. Goldstraw S9 Percutaneous radiofrequency ablation of unresectable locally advanced pancreatic cancer: preliminary results D’Onofrio M, Ciaravino V, Crosara S, De Robertis R, Pozzi Mucelli R S10 Iodine maps from dual energy CT improve detection of metastases in staging examinations of melanoma patients M. Uhrig, D. Simons, H. Schlemmer S11Can contrast enhanced CT predict pelvic nodal status in malignant melanoma of the lower limb? Kate Downey S12 Current practice in the investigation for suspected Paraneoplastic Neurological Syndromes (PNS) and positive malignancy yield. S Murdoch, AS Al-adhami, S Viswanathan P1 Technical success and efficacy of Pulmonary Radiofrequency ablation: an analysis of 207 ablations S Smith, P Jennings, D Bowers, R Soomal P2 Lesion control and patient outcome: prospective analysis of radiofrequency abaltion in pulmonary colorectal cancer metastatic disease S Smith, P Jennings, D Bowers, R Soomal P3 Hepatocellular carcinoma in a post-TB patient: case of tropical infections and oncologic imaging challenges TM Mutala, AO Odhiambo, N Harish P4 Role of apparent diffusion coefficient (ADC) diffusion-weighted MRI for predicting extracapsular extension of prostate cancer P. Pricolo, S. Alessi, P. Summers, E. Tagliabue, G. Petralia P5 What a difference a decade makes; comparison of lung biopsies in Glasgow 2005 and 2015 M. Hall, M. Sproule, S. Sheridan P6 Solid pseudopapillary tumour of pancreas: imaging features of a rare neoplasm KY Thein, CH Tan, YL Thian, CM Ho P7 MDCT - pathological correlation in colon adenocarcinoma staging: preliminary experience S De Luca, C Carrera, V Blanchet, L AlarcĂłn, E Eyheremnedy P8 Image guided biopsy of thoracic masses and reduction of pneumothorax risk: 25 years experience B K Choudhury, K Bujarbarua, G Barman P9 Tumour heterogeneity analysis of 18F-FDG-PET for characterisation of malignant peripheral nerve sheath tumours in neurofibromatosis-1 GJ Cook, E Lovat, M Siddique, V Goh, R Ferner, VS Warbey P10 Impact of introduction of vacuum assisted excision (VAE) on screen detected high risk breast lesions L Potti, B Kaye, A Beattie, K Dutton P11 Can we reduce prevalent recall rate in breast screening? AA Seth, F Constantinidis, H Dobson P12 How to reduce prevalent recall rate? Identifying mammographic lesions with low Positive Predictive Value (PPV) AA Seth ([email protected]), F Constantinidis, H Dobson P13 Behaviour of untreated pulmonary thrombus in oncology patients diagnosed with incidental pulmonary embolism on CT R. Bradley, G. Bozas, G. Avery, A. Stephens, A. Maraveyas P14 A one-stop lymphoma biopsy service – is it possible? S Bhuva, CA Johnson, M Subesinghe, N Taylor P15 Changes in the new TNM classification for lung cancer (8th edition, effective January 2017) LE Quint, RM Reddy, GP Kalemkerian P16 Cancer immunotherapy: a review of adequate imaging assessment G GonzĂĄlez Zapico, E Gainza Jauregui, R Álvarez Francisco, S Ibåñez Alonso, I Tavera Bahillo, L MĂșgica Álvarez P17 Succinate dehydrogenase mutations and their associated tumours O Francies, R Wheeler, L Childs, A Adams, A Sahdev P18 Initial experience in the usefulness of dual energy technique in the abdomen SE De Luca, ME Casalini Vañek, MD Pascuzzi, T Gillanders, PM Ramos, EP Eyheremendy P19 Recognising the serious complication of Richter’s transformation in CLL patients C Stove, M Digby P20 Body diffusion-weighted MRI in oncologic practice: truths, tricks and tips M. Nazar, M. Wirtz, MD. Pascuzzi, F. Troncoso, F. Saguier, EP. Eyheremendy P21 Methotrexate-induced leukoencephalopathy in paediatric ALL Patients D.J. Quint, L. Dang, M. Carlson, S. Leber, F. Silverstein P22 Pitfalls in oncology CT reporting. A pictorial review R Rueben, S Viswanathan P23 Imaging of perineural extension in head and neck tumours B Nazir, TH Teo, JB Khoo P24 MRI findings of molecular subtypes of breast cancer: a pictorial primer K Sharma, N Gupta, B Mathew, T Jeyakumar, K Harkins P25 When cancer can’t wait! A pictorial review of oncological emergencies K Sharma, B Mathew, N Gupta, T Jeyakumar, S Joshua P26 MRI of pancreatic neuroendocrine tumours: an approach to interpretation D Christodoulou, S Gourtsoyianni, A Jacques, N Griffin, V Goh P27 Gynaecological cancers in pregnancy: a review of imaging CA Johnson, J Lee P28 Suspected paraneoplastic neurological syndromes - review of published recommendations to date, with proposed guideline/flowchart JA Goodfellow, AS Al-adhami, S Viswanathan P29 Multi-parametric MRI of the pelvis for suspected local recurrence of prostate cancer after radical prostatectomy R Bradley P30 Utilisation of PI-RADS version 2 in multi-parametric MRI of the prostate; 12-months experience R Bradley P31 Radiological assessment of the post-chemotherapy liver A Yong, S Jenkins, G Joseph P32 Skeletal staging with MRI in breast cancer – what the radiologist needs to know S Bhuva, K Partington P33 Perineural spread of lympoma: an educational review of an unusual distribution of disease CA Johnson, S Bhuva, M Subesinghe, N Taylor P34 Visually isoattenuating pancreatic adenocarcinoma. Diagnostic imaging tools. C Carrera, A Zanfardini, S De Luca, L AlarcĂłn, V Blanchet, EP Eyheremendy P35 Imaging of larynx cancer: when is CT, MRI or FDG PET/CT the best test? K Cavanagh, E Lauhttp://deepblue.lib.umich.edu/bitstream/2027.42/134651/1/40644_2016_Article_79.pd

    Low exposure long-baseline neutrino oscillation sensitivity of the DUNE experiment

    Full text link
    The Deep Underground Neutrino Experiment (DUNE) will produce world-leading neutrino oscillation measurements over the lifetime of the experiment. In this work, we explore DUNE's sensitivity to observe charge-parity violation (CPV) in the neutrino sector, and to resolve the mass ordering, for exposures of up to 100 kiloton-megawatt-years (kt-MW-yr). The analysis includes detailed uncertainties on the flux prediction, the neutrino interaction model, and detector effects. We demonstrate that DUNE will be able to unambiguously resolve the neutrino mass ordering at a 3σ\sigma (5σ\sigma) level, with a 66 (100) kt-MW-yr far detector exposure, and has the ability to make strong statements at significantly shorter exposures depending on the true value of other oscillation parameters. We also show that DUNE has the potential to make a robust measurement of CPV at a 3σ\sigma level with a 100 kt-MW-yr exposure for the maximally CP-violating values \delta_{\rm CP}} = \pm\pi/2. Additionally, the dependence of DUNE's sensitivity on the exposure taken in neutrino-enhanced and antineutrino-enhanced running is discussed. An equal fraction of exposure taken in each beam mode is found to be close to optimal when considered over the entire space of interest

    Snowmass Neutrino Frontier: DUNE Physics Summary

    Get PDF
    The Deep Underground Neutrino Experiment (DUNE) is a next-generation long-baseline neutrino oscillation experiment with a primary physics goal of observing neutrino and antineutrino oscillation patterns to precisely measure the parameters governing long-baseline neutrino oscillation in a single experiment, and to test the three-flavor paradigm. DUNE's design has been developed by a large, international collaboration of scientists and engineers to have unique capability to measure neutrino oscillation as a function of energy in a broadband beam, to resolve degeneracy among oscillation parameters, and to control systematic uncertainty using the exquisite imaging capability of massive LArTPC far detector modules and an argon-based near detector. DUNE's neutrino oscillation measurements will unambiguously resolve the neutrino mass ordering and provide the sensitivity to discover CP violation in neutrinos for a wide range of possible values of ÎŽCP. DUNE is also uniquely sensitive to electron neutrinos from a galactic supernova burst, and to a broad range of physics beyond the Standard Model (BSM), including nucleon decays. DUNE is anticipated to begin collecting physics data with Phase I, an initial experiment configuration consisting of two far detector modules and a minimal suite of near detector components, with a 1.2 MW proton beam. To realize its extensive, world-leading physics potential requires the full scope of DUNE be completed in Phase II. The three Phase II upgrades are all necessary to achieve DUNE's physics goals: (1) addition of far detector modules three and four for a total FD fiducial mass of at least 40 kt, (2) upgrade of the proton beam power from 1.2 MW to 2.4 MW, and (3) replacement of the near detector's temporary muon spectrometer with a magnetized, high-pressure gaseous argon TPC and calorimeter

    Snowmass Neutrino Frontier: DUNE Physics Summary

    Full text link
    The Deep Underground Neutrino Experiment (DUNE) is a next-generation long-baseline neutrino oscillation experiment with a primary physics goal of observing neutrino and antineutrino oscillation patterns to precisely measure the parameters governing long-baseline neutrino oscillation in a single experiment, and to test the three-flavor paradigm. DUNE's design has been developed by a large, international collaboration of scientists and engineers to have unique capability to measure neutrino oscillation as a function of energy in a broadband beam, to resolve degeneracy among oscillation parameters, and to control systematic uncertainty using the exquisite imaging capability of massive LArTPC far detector modules and an argon-based near detector. DUNE's neutrino oscillation measurements will unambiguously resolve the neutrino mass ordering and provide the sensitivity to discover CP violation in neutrinos for a wide range of possible values of ÎŽCP\delta_{CP}. DUNE is also uniquely sensitive to electron neutrinos from a galactic supernova burst, and to a broad range of physics beyond the Standard Model (BSM), including nucleon decays. DUNE is anticipated to begin collecting physics data with Phase I, an initial experiment configuration consisting of two far detector modules and a minimal suite of near detector components, with a 1.2 MW proton beam. To realize its extensive, world-leading physics potential requires the full scope of DUNE be completed in Phase II. The three Phase II upgrades are all necessary to achieve DUNE's physics goals: (1) addition of far detector modules three and four for a total FD fiducial mass of at least 40 kt, (2) upgrade of the proton beam power from 1.2 MW to 2.4 MW, and (3) replacement of the near detector's temporary muon spectrometer with a magnetized, high-pressure gaseous argon TPC and calorimeter.Comment: Contribution to Snowmass 202

    A Gaseous Argon-Based Near Detector to Enhance the Physics Capabilities of DUNE

    Get PDF
    This document presents the concept and physics case for a magnetized gaseous argon-based detector system (ND-GAr) for the Deep Underground Neutrino Experiment (DUNE) Near Detector. This detector system is required in order for DUNE to reach its full physics potential in the measurement of CP violation and in delivering precision measurements of oscillation parameters. In addition to its critical role in the long-baseline oscillation program, ND-GAr will extend the overall physics program of DUNE. The LBNF high-intensity proton beam will provide a large flux of neutrinos that is sampled by ND-GAr, enabling DUNE to discover new particles and search for new interactions and symmetries beyond those predicted in the Standard Model

    A Gaseous Argon-Based Near Detector to Enhance the Physics Capabilities of DUNE

    Full text link
    This document presents the concept and physics case for a magnetized gaseous argon-based detector system (ND-GAr) for the Deep Underground Neutrino Experiment (DUNE) Near Detector. This detector system is required in order for DUNE to reach its full physics potential in the measurement of CP violation and in delivering precision measurements of oscillation parameters. In addition to its critical role in the long-baseline oscillation program, ND-GAr will extend the overall physics program of DUNE. The LBNF high-intensity proton beam will provide a large flux of neutrinos that is sampled by ND-GAr, enabling DUNE to discover new particles and search for new interactions and symmetries beyond those predicted in the Standard Model.Comment: Contribution to Snowmass 202

    Reconstruction of interactions in the ProtoDUNE-SP detector with Pandora

    Get PDF
    The Pandora Software Development Kit and algorithm libraries provide pattern-recognition logic essential to the reconstruction of particle interactions in liquid argon time projection chamber detectors. Pandora is the primary event reconstruction software used at ProtoDUNE-SP, a prototype for the Deep Underground Neutrino Experiment far detector. ProtoDUNE-SP, located at CERN, is exposed to a charged-particle test beam. This paper gives an overview of the Pandora reconstruction algorithms and how they have been tailored for use at ProtoDUNE-SP. In complex events with numerous cosmic-ray and beam background particles, the simulated reconstruction and identification efficiency for triggered test-beam particles is above 80% for the majority of particle type and beam momentum combinations. Specifically, simulated 1 GeV/cc charged pions and protons are correctly reconstructed and identified with efficiencies of 86.1±0.6\pm0.6% and 84.1±0.6\pm0.6%, respectively. The efficiencies measured for test-beam data are shown to be within 5% of those predicted by the simulation.Comment: 39 pages, 19 figure
    • 

    corecore