1,180 research outputs found

    Orthodontic bonding to silicate ceramics: impact of different pretreatment methods on shear bond strength between ceramic restorations and ceramic brackets

    Get PDF
    Objective The study aims to investigate the shear bond strength (SBS) between silicate ceramic restorations and ceramic brackets after different pretreatments and aging methods. Material and methods Leucite (LEU) and lithium disilicate (LiSi) specimens were pretreated with (i) 4% hydrofluoric acid + silane (HF), (ii) Monobond Etch&Prime (MEP), (iii) silicatization + silane (CoJet), and (iv) SiC grinder + silane (SiC). Molars etched (phosphoric acid) and conditioned acted as comparison group. SBS was measured after 24 h (distilled water, 37 °C), 500 × thermocycling (5/55 °C), and 90 days (distilled water, 37 °C). Data was analyzed using Shapiro–Wilk, Kruskal–Wallis with Dunn’s post hoc test and Bonferroni correction, Mann–Whitney U, and Chi2 test (p < 0.05). The adhesive remnant index (ARI) was determined. Results LEU pretreated with MEP showed lower SBS than pretreated with HF, CoJet, or SiC. LiSi pretreated with MEP resulted in lower initial SBS than pretreated with HF or SiC. After thermocycling, pretreatment using MEP led to lower SBS than with CoJet. Within LiSi group, after 90 days, the pretreatment using SiC resulted in lowest SBS values. After HF and MEP pretreatment, LEU showed lower initial SBS than LiSi. After 90 days of water storage, within specimens pretreated using CoJet or SiC showed LEU higher SBS than LiSi. Enamel presented higher or comparable SBS values to LEU and LiSi. With exception of MEP pretreatment, ARI 3 was predominantly observed, regardless the substrate, pretreatment, and aging level. Conclusions MEP pretreatment presented the lowest SBS values, regardless the silicate ceramic and aging level. Further research is necessary. Clinical relevance There is no need for intraoral application of HF for orthodontic treatment

    Wound healing in rabbit corneas after flapless refractive lenticule extraction with a 345 nm ultraviolet femtosecond laser

    Get PDF
    Purpose To characterize corneal wound healing in a rabbit model after flapless refractive lenticule extraction with a 345 nm ultraviolet femtosecond laser. Setting Departments of Ophthalmology and Anatomy II, University of Erlangen-Nürnberg and Wavelight GmbH, Erlangen, Germany. Design Methods Flapless refractive lenticule extraction was performed in 1 eye each of 20 New Zealand white rabbits (−5.0 diopters). Groups of 4 animals were euthanized after 48 hours, 1 week, 2 weeks, 4 weeks, and 3 months, respectively. Corneal samples were prepared for histology and fluorescence microscopy. To assess corneal cell death, proliferation, and myofibroblastic transdifferentiation, terminal uridine deoxynucleotidyl nick end-labeling (TUNEL) assay as well as immunostaining for Ki67 and α-smooth muscle actin (αSMA) were performed on sagittal cryosections. Results Histology revealed a zone of keratocyte depletion with a thickness of approximately 50 μm around the extraction site. At 48 hours, pronounced TUNEL staining of keratocytes was detected around the interface (159.9 cells/mm ± 18.4 [SD]), which steadily decreased to 74.9 ± 19.8 cells/mm at 1 week and 5.7 ± 4.8 cells/mm at 2 weeks. Ki67 staining of keratocytes was evident at 48 hours (10.0 ± 3.8 cells/mm), which then decreased at 1 week (5.2 ± 1.7 cells/mm) and 2 weeks (0.4 ± 0.5 cells/mm). From 4 weeks onward, no TUNEL or Ki67 staining was detected. The corneal stroma was αSMA-negative at all timepoints. Conclusion Application of the 345 nm laser showed no signs of problematic repair processes in the cornea, which supports the initiation of the clinical phase

    Curvature-dependent shear bond strength of different attachment materials for orthodontic lingual indirect bonding

    Get PDF
    Abstract To evaluate the shear bond strength (SBS) of different attachment materials used for lingual bonding, the influence of artificial aging and the radii of curvature of the enamel surface on SBS, 192 third molars were photographed to determine the radius of curvature of the oral surface. After phosphoric acid etching a cylindrical test piece was bonded to the oral enamel using a mold that was filled with a chemically curing (Maximum Cure, Transbond IDB Premix) or a dual-curing (Nexus NX3, RelyX Unicem2) attachment material. SBS was tested after 24 h, 500 thermal cycles or 90 days at 37 °C with a universal testing machine. Computed tomography scans were performed to determine the bonded surface and calculate SBS. Values ranged from 8.3 to 20.9 MPa. RelyX Unicem2 showed the highest SBS values at baseline, 500 thermal cycles and after 90 days (p < 0.001). Ninety days of wet storage significantly reduced SBS of Maximum Cure (p = 0.028). The radius of curvature correlated positively with SBS (rs = 0.204, p = 0.005). The SBS of all attachment materials was sufficient for clinical use, even after artificial aging. RelyX Unicem2 showed almost twice as high SBS values as the other attachment materials

    Usability of abattoir-acquired pig eyes for refractive excimer laser research

    Get PDF
    The purpose of this study was to elucidate, under which conditions abattoir-acquired pig eyes are suitable for refractive excimer laser experiments. Porcine eyes from tunnel-scalded (n = 5) and tank-scalded (n = 10) pigs were compared to unscalded eyes (n = 5) and to eyes scalded in the laboratory (n = 5). The corneal epithelium was removed before an excimer laser was used to perform a − 8.0 D photoablation. Corneal thickness was measured by optical coherence topography before and after photoablation. The ablation depth was determined with a contour measuring station, the morphology of the ablated areas was characterized by scanning electron microscopy and white-light profilometry. The scalded eyes showed an increase in corneal swelling which gained statistical significance in tank-scalded eyes showing a wedge-shaped opaque stromal lesion in the nasal corneal quadrant. A measurable deterioration of photoablation was only found in tank-scalded eyes that exhibited the opaque lesion. Ablated area morphology was smooth and regular in the unscalded and tunnel-scalded eyes. The tank-scalded eyes showed conspicuous wrinkles. While unscalded eyes should always be preferred for excimer laser laboratory experiments, the data suggest that the use of tunnel-scalded eyes may also be acceptable and should be chosen over tank-scalded eyes

    Neurocritical care complications and interventions influence the outcome in aneurysmal subarachnoid hemorrhage

    Get PDF
    Background This observational study was performed to show the impact of complications and interventions during neurocritical care on the outcome after aneurysmal subarachnoid hemorrhage (SAH). Methods We analyzed 203 cases treated for ruptured intracranial aneurysms, which were classified regarding clinical outcome after one year according to the modified Rankin Scale (mRS). We reviewed the data with reference to the occurrence of typical complications and interventions in neurocritical care units. Results Decompressive craniectomy (odds ratio 21.77 / 6.17 ; p < 0.0001 / p = 0.013), sepsis (odds ratio 14.67 / 6.08 ; p = 0.037 / 0.033) and hydrocephalus (odds ratio 3.71 / 6.46 ; p = 0.010 / 0.00095) were significant predictors for poor outcome and death after one year beside “World Federation of Neurosurgical Societies” (WFNS) grade (odds ratio 3.86 / 4.67 ; p < 0.0001 / p < 0.0001) and age (odds ratio 1.06 / 1.10 ; p = 0.0030 / p < 0.0001) in our multivariate analysis (binary logistic regression model). Conclusions In summary, decompressive craniectomy, sepsis and hydrocephalus significantly influence the outcome and occurrence of death after aneurysmal SAH

    Impact of polishing system on surface roughness of different ceramic surfaces after various pretreatments and bracket debonding

    Get PDF
    Objective Evaluating various polishing methods after bracket debonding and excessive attachment material removal for different ceramics and pretreatments. Material and methods Zirconia (ZrO2), leucite (LEU) and lithium disilicate (LiSi) specimens were pretreated with a) silica coated alumina particles (CoJet); LEU and LiSi additionally with b) hydrofluoric acid (HF), c) Monobond Etch&Prime (MEP), d) silicium carbide grinder (SiC) before bracket bonding, shearing off, ARI evaluation, excessive attachment material removal and polishing with i) Sof-Lex Discs (Soflex), ii) polishing paste (Paste), iii) polishing set (Set). Before/after polishing surface roughness (Ra) was measured with a profilometer. Martens hardness parameter were also assessed. Results Irrespective of pretreatment Ra of LEU increased the most, followed by LiSi and ZrO2 (p < 0.001, SiC: p = 0.012), in accordance with the measured Martens hardness parameter. CoJet/SiC caused greater roughness as HF/MEP (p < 0.001). The ZrO2 surface was rougher after polishing with Paste/Set (p < 0.001; p = 0.047). Ra improved in the LEU/CoJet, LEU/SiC and LiSi/SiC groups with Soflex/Set (p < 0.001), in the LiSi/CoJet and LEU/HF groups by Soflex (p = 0.003, p < 0.001) and worsened by Paste (p = 0.017, p < 0.001). Polishing of HF or MEP pretreated LiSi with Set increased Ra (p = 0.001, p < 0.001), so did Paste in the LEU/MEP group (p < 0.001). Conclusions Paste couldn’t improve the surfaces. Soflex was the only method decreasing Ra on rough surfaces and not causing roughness worsening. Polishing of LEU/LiSi after MEP, LEU after HF pretreatment doesn´t seem to have any benefit. Clinical Relevance To avoid long-term damage to ceramic restorations, special attention should be paid to the polishing method after orthodontic treatment

    Acetylcholine receptors (muscarinic) (version 2019.4) in the IUPHAR/BPS Guide to Pharmacology Database

    Get PDF
    Muscarinic acetylcholine receptors (nomenclature as agreed by the NC-IUPHAR Subcommittee on Muscarinic Acetylcholine Receptors [45]) are GPCRs of the Class A, rhodopsin-like family where the endogenous agonist is acetylcholine. In addition to the agents listed in the table, AC-42, its structural analogues AC-260584 and 77-LH-28-1, N-desmethylclozapine, TBPB and LuAE51090 have been described as functionally selective agonists of the M1 receptor subtype via binding in a mode distinct from that utilized by non-selective agonists [243, 242, 253, 155, 154, 181, 137, 11, 230]. There are two pharmacologically characterised allosteric sites on muscarinic receptors, one defined by it binding gallamine, strychnine and brucine, and the other defined by the binding of KT 5720, WIN 62,577, WIN 51,708 and staurosporine [161, 162]

    Acetylcholine receptors (muscarinic) in GtoPdb v.2023.1

    Get PDF
    Muscarinic acetylcholine receptors (mAChRs) (nomenclature as agreed by the NC-IUPHAR Subcommittee on Muscarinic Acetylcholine Receptors [53]) are activated by the endogenous agonist acetylcholine. All five (M1-M5) mAChRs are ubiquitously expressed in the human body and are therefore attractive targets for many disorders. Functionally, M1, M3, and M5 mAChRs preferentially couple to Gq/11 proteins, whilst M2 and M4 mAChRs predominantly couple to Gi/o proteins. Both agonists and antagonists of mAChRs are clinically approved drugs, including pilocarpine for the treatment of elevated intra-ocular pressure and glaucoma, and atropine for the treatment of bradycardia and poisoning by muscarinic agents such as organophosphates. Of note, it has been observed that mAChRs dimerise reversibly [134] and that dimerisation/oligomerisation can be affected by ligands [183, 196]
    corecore