28 research outputs found

    A walk in the maze: variation in Late Jurassic tridactyl dinosaur tracks from the Swiss Jura Mountains (NW Switzerland)

    Get PDF
    Background: Minute to medium-sized (footprint length (FL) less than 30 cm) tridactyl dinosaur tracks are the most abundant in the Late Jurassic tracksites of Highway A16 (Reuchenette Formation, Kimmeridgian) in the Jura Mountains (NW Switzerland). During excavations, two morphotypes, one gracile and one robust, were identified in the field. Furthermore, two large-sized theropod ichnospecies (Megalosauripus transjuranicus and Jurabrontes curtedulensis) and an ornithopod-like morphotype (Morphotype II) have recently been described at these sites. Methods: The quality of morphological preservation (preservation grade), the depth of the footprint, the shape variation, and the footprint proportions (FL/footprint width (FW) ratio and mesaxony) along the trackways have been analyzed using 3D models and false-color depth maps in order to determine the exact number of small to medium-sized morphotypes present in the tracksites. Results: The study of footprints (n = 93) recovered during the excavations has made it possible to identify and characterize the two morphotypes distinguished in the field. The gracile morphotype is mainly characterized by a high FL/FW ratio, high mesaxony, low divarication angles and clear, sharp claw marks, and phalangeal pads (2-3-4). By contrast, the robust morphotype is characterized by a lower FL/FW ratio, weaker mesaxony, slightly higher divarication angles and clear, sharp claw marks (when preserved), whereas the phalangeal pads are not clearly preserved although they might be present. Discussion: The analysis does not allow the two morphotypes to be associated within the same morphological continuum. Thus, they cannot be extramorphological variations of similar tracks produced by a single trackmaker. Comparison of the two morphotypes with the larger morphotypes described in the formation (M. transjuranicus, J. curtedulensis, and Morphotype II) and the spatio-temporal relationships of the trackways suggest that the smaller morphotypes cannot reliably be considered as small individuals of any of the larger morphotypes. The morphometric data of some specimens of the robust morphotype (even lower values for the length/width ratio and mesaxony) suggest that more than one ichnotaxon might be represented within the robust morphotype. The features of the gracile morphotype (cf. Kalohipus isp.) are typical of "grallatorid" ichnotaxa with low mesaxony whereas those of the robust morphotype (cf. Therangospodus isp. and Therangospodus? isp.) are reminiscent of Therangospodus pandemicus. This work sheds new light on combining an analysis of variations in footprint morphology through 3D models and false-color depth maps, with the study of possible ontogenetic variations and the identification of small-sized tridactyl ichnotaxa for the description of new dinosaur tracks

    MR Volumetry of Lung Nodules: A Pilot Study

    Get PDF
    Introduction: Computed tomography (CT) is currently the reference modality for the detection and follow-up of pulmonary nodules. While 2D measurements are commonly used in clinical practice to assess growth, increasingly 3D volume measurements are being recommended. The goal of this pilot study was to evaluate preliminarily the capabilities of 3D MRI using ultra-short echo time for lung nodule volumetry, as it would provide a radiation-free modality for this task.Material and Methods: Artificial nodules were manufactured out of Agar and measured using an ultra-short echo time MRI sequence. CT data were also acquired as a reference. Image segmentation was carried out using an algorithm based on signal intensity thresholding (SIT). For comparison purposes, we also performed manual slice by slice segmentation. Volumes obtained with MRI and CT were compared. Finally, the volumetry of a lung nodule was evaluated in one human subject in comparison with CT.Results: Using the SIT technique, minimal bias was observed between CT and MRI across the entire range of volumes (2%) with limits of agreement below 14%. Comparison of manually segmented MRI and CT resulted in a larger bias (8%) and wider limits of agreement (−23% to 40%). In vivo, nodule volume differed of <16% between modalities with the SIT technique.Conclusion: This pilot study showed very good concordance between CT and UTE-MRI to quantify lung nodule volumes, in both a phantom and human setting. Our results enhance the potential of MRI to quantify pulmonary nodule volume with similar performance to CT

    Biomedical data management: a proposal framework

    No full text
    The expansion of biomedical knowledge, reductions in computing costs and spread of IT facilities have led to an explosion of the biomedical electronic data. However, these data are rarely integrated and analysed because of lack of tools. The integration process is complex due to technical and semantic heterogeneity as well as lack of reliability in such distributed system. In addition, for the specific case of biomedical data, privacy is a crucial constraint. This paper presents a pilot system that will be used in the European FP7 DebugIT project to integrate biomedical data from several healthcare centres across Europe
    corecore