138 research outputs found
Vibrations of micro-eV energies in nanocrystalline microstructures
The phonon density of states of nanocrystalline bcc Fe and nanocrystalline fcc Ni3Fe were measured by inelastic neutron scattering in two different ranges of energy. As has been reported previously, the nanocrystalline materials showed enhancements in their phonon density of states at energies from 2 to 15 meV, compared to control samples composed of large crystals. The present measurements were extended to energies in the micro-eV range, and showed significant, but smaller, enhancements in the number of modes in the energy range from 5 to 18 mueV. These modes of micro-eV energies provide a long-wavelength limit that bounds the fraction of modes at milli-eV energies originating with the cooperative dynamics of the nanocrystalline microstructure
Experimental study of 199Hg spin anti-relaxation coatings
We report on a comparison of spin relaxation rates in a Hg
magnetometer using different wall coatings. A compact mercury magnetometer was
built for this purpose. Glass cells coated with fluorinated materials show
longer spin coherence times than if coated with their hydrogenated homologues.
The longest spin relaxation time of the mercury vapor was measured with a
fluorinated paraffin wall coating.Comment: 9 pages, 6 figures, submitted to JINS
An Absolute Measurement of Neutron Flux Using Calorimetry
This research was sponsored by the National Science Foundation Grant NSF PHY-931478
An endoscopic detector for ultracold neutrons
A new versatile detector for ultracold neutrons (UCN) has been built and operated which combines multi-pixel photon counters and GS10 lithium-doped scintillators. Such detectors can be very small and can be used to monitor UCN inside storage vessels or guides with negligible influence (of order 10−6 on the UCN intensity itself. We have shown that such detectors can be used in a very harsh radiation environment of up to 200Gy/h via the addition of a 4m long quartz light guide in order to place the radiation-sensitive photon counters outside the hot zone. Additionally we have measured the UCN storage times in situ in this harsh environmen
A highly stable atomic vector magnetometer based on free spin precession
We present a magnetometer based on optically pumped Cs atoms that measures
the magnitude and direction of a 1 T magnetic field. Multiple circularly
polarized laser beams were used to probe the free spin precession of the Cs
atoms. The design was optimized for long-time stability and achieves a scalar
resolution better than 300 fT for integration times ranging from 80 ms to 1000
s. The best scalar resolution of less than 80 fT was reached with integration
times of 1.6 to 6 s. We were able to measure the magnetic field direction with
a resolution better than 10 rad for integration times from 10 s up to 2000
s
Neutron cross sections for He-3 at epithermal energies
High accuracy, absolute measurements of the neutron total cross section for He-3 are reported for incident neutron energies 0.1-400 eV. The measurements were performed at the LANSCE short-pulse neutron spallation source. Using the previously determined cross section for neutron elastic scattering, 3.367+/-0.019 b, we extract a new value for the energy dependence of the He-3(n,p)He-3 reaction cross section, sigma(np)=(849.77+/-0.14+/-1.02)E-1/2-(1.253+/-0.00+/-(+0.008)(-0.049))b, where the neutron energy is expressed in eV. The first uncertainty is statistical, the second systematic
An Improved Search for the Neutron Electric Dipole Moment
A permanent electric dipole moment of fundamental spin-1/2 particles violates
both parity (P) and time re- versal (T) symmetry, and hence, also charge-parity
(CP) symmetry since there is no sign of CPT-violation. The search for a neutron
electric dipole moment (nEDM) probes CP violation within and beyond the Stan-
dard Model. The experiment, set up at the Paul Scherrer Institute (PSI), an
improved, upgraded version of the apparatus which provided the current best
experimental limit, dn < 2.9E-26 ecm (90% C.L.), by the RAL/Sussex/ILL
collaboration: Baker et al., Phys. Rev. Lett. 97, 131801 (2006). In the next
two years we aim to improve the sensitivity of the apparatus to sigma(dn) =
2.6E-27 ecm corresponding to an upper limit of dn < 5E-27 ecm (95% C.L.), in
case for a null result. In parallel the collaboration works on the design of a
new apparatus to further increase the sensitivity to sigma(dn) = 2.6E-28 ecm.Comment: APS Division for particles and fields, Conference Proceedings, Two
figure
Experimental study of 199Hg spin anti-relaxation coatings
We report on a comparison of spin relaxation rates in a 199Hg magnetometer using different wall coatings. A compact mercury magnetometer was built for this purpose. Glass cells coated with fluorinated materials show longer spin coherence times than if coated with their hydrogenated homologues. The longest spin relaxation time of the mercury vapor was measured with a fluorinated paraffin wall coating
- …