2,423 research outputs found
On Electrical Equivalence of Aperture-Body and Transmission-Cavity Resonance Phenomena in Subwavelength Conducting Aperture Systems from an Equivalent Circuit Point of View
For a narrow slit structure backed by a conducting strip which is taken as a
representative example of an aperture-body resonance (ABR) problem, the
transmission resonance condition (i.e., condition for maximum power
transmission) and the transmission width (i.e., normalized maximum transmitted
power through the slit) are found to be the same as those for narrow slit
coupling problem in a thick conducting screen, which is designated as a
transmission-cavity resonance (TCR) problem. From a viewpoint of equivalent
circuit representation for the transmission resonance condition and the
funneling mechanism, the ABR and the TCR problems are thought to be essentially
of the same nature.Comment: 14 pages, 3 figure
The effect of phenylephrine on the onset time of rocuronium
BACKGROUND: Several studies have demonstrated that ephedrine shortens the onset time of muscle relaxants, and it does so probably by increasing the cardiac output. However, elevation of the systemic blood pressure through α adrenergic stimulation via ephedrine may affect the onset of muscle relaxants during the induction of anesthesia. We investigated the effect of phenylephrine, which is a selective α-1 agonist, on the onset time of rocuronium and the intubating conditions in adults after the administration of propofol.
METHODS: Sixty-four patients were randomly assigned to two groups. Phenylephrine (0.9 µg/kg) (P group) or the same volume of saline (S group) was injected before rocuronium (0.6 mg/kg) administration. Anesthesia was induced with fentanyl 2 µg/kg and propofol 2 mg/kg. The onset time was defined as the time from the end of rocuronium injection to the time when a single twitch height gets to 0% or the minimum level. A well-trained anesthesiologist who was 'blinded' to the treatment groups evaluated the intubating conditions. The mean arterial pressure and heart rate were recorded before induction, before intubation, immediately after intubation and 1 minute and 2 minutes after intubation.
RESULTS: The onset time was 84 ± 18 sec in the P-group and 72 ± 14 sec in the S-group. There was no difference of the intubating conditions, the mean arterial pressure and the heart rate between the two groups.
CONCLUSIONS: A small dose of phenylephrine, which has a limited effect on blood pressure, delayed the onset time of rocuronium after the administration of propofol, and the vasoconstriction effect of phenylephrine may affect the prolongation of the rocuronium onset time at the induction of anesthesia with using propofol.ope
Cored Dark Matter halos in the Cosmic Neutrino Background
We study the impact of the interaction between DM and the cosmic neutrino
background on the evolution of galactic dark matter halos. The energy transfer
from the neutrinos to the dark matter can heat the center of the galaxy and
make it cored. This effect is efficient for the small galaxies such as the
satellite galaxies of the Milky Way and we can put conservative constraint on
the non-relativistic elastic scattering cross section as
for 0.1 keV dark matter and 0.1
eV neutrino.Comment: 7 pages, 5 figure
Online home appliance control using EEG-Based brain-computer interfaces
Brain???computer interfaces (BCIs) allow patients with paralysis to control external devices by mental commands. Recent advances in home automation and the Internet of things may extend the horizon of BCI applications into daily living environments at home. In this study, we developed an online BCI based on scalp electroencephalography (EEG) to control home appliances. The BCI users controlled TV channels, a digital door-lock system, and an electric light system in an unshielded environment. The BCI was designed to harness P300 andN200 components of event-related potentials (ERPs). On average, the BCI users could control TV channels with an accuracy of 83.0% ?? 17.9%, the digital door-lock with 78.7% ?? 16.2% accuracy, and the light with 80.0% ?? 15.6% accuracy, respectively. Our study demonstrates a feasibility to control multiple home appliances using EEG-based BCIs
Recommended from our members
Comparison of the Plasma Metabolome Profiles Between the Internal Thoracic Artery and Ascending Aorta in Patients Undergoing Coronary Artery Bypass Graft Surgery Using Gas Chromatography Time-of-Flight Mass Spectrometry.
BackgroundThe left internal thoracic artery (LITA) has been used as the first conduit of choice in coronary artery bypass grafting (CABG) because of excellent long-term patency and outcomes. However, no studies have examined substances other than nitric oxide that could be beneficial for the bypass conduit, native coronary artery or ischemic myocardium. This study was conducted to evaluate differences in metabolic profiles between the LITA and ascending aorta using gas chromatography-time of flight-mass spectrometry (GC-TOF-MS).MethodsTwenty patients who underwent CABG using the LITA were prospectively enrolled. Plasma samples were collected simultaneously from the LITA and ascending aorta. GC-TOF-MS based untargeted metabolomic analyses were performed and a 2-step volcano plot analysis was used to identify distinguishable markers from two plasma metabolome profiles. Semi-quantitative and quantitative analyses were performed using GC-TOF-MS and enzyme-linked immunosorbent assay, respectively, after selecting target metabolites based on the metabolite set enrichment analysis.ResultsInitial volcano plot analysis demonstrated 5 possible markers among 851 peaks detected. The final analysis demonstrated that the L-cysteine peak was significantly higher in the LITA than in the ascending aorta (fold change = 1.86). The concentrations of intermediate metabolites such as L-cysteine, L-methionine and L-cystine in the 'cysteine and methionine metabolism pathway' were significantly higher in the LITA than in the ascending aorta (2.0-, 1.4- and 1.2-fold, respectively). Quantitative analysis showed that the concentration of hydrogen sulfide (H₂S) was significantly higher in the LITA.ConclusionThe plasma metabolome profiles of the LITA and ascending aorta were different, particularly higher plasma concentrations of L-cysteine and H₂S in the LITA
The North Pacific Oxygen Uptake Rates Over the Past Half-Century
The transport of dissolved oxygen (O2) from the surface ocean into the interior is a critical process sustaining aerobic life in mesopelagic ecosystems, but its rates and sensitivity to climate variations are poorly understood. Using a circulation model constrained to historical variability by assimilation of observations, we show that the North Pacific thermocline effectively takes up O2 primarily by expanding the area through which O2-rich mixed layer water is detrained into the thermocline. The outcrop area during the critical winter season varies in concert with the Pacific Decadal Oscillation (PDO). When the central North Pacific Ocean is in a cold phase, the winter outcrop window for the Central Mode Water class (CMW; a neutral density range of γ = 25.6 - 26.6) expands southward allowing more O2-rich surface water to enter the ocean’s interior. An increase in volume flux of water to the CMW density class is partly compensated by a reduced supply to the shallower densities of Subtropical Mode Water (γ = 24.0 - 25.5). The thermocline has become better oxygenated since the 1980s due partly to strong O2 uptake. Positive O2 anomalies appear first near the outcrop and subsequently downstream in the subtropical gyre. In contrast to the O2 variations within the ventilated thermocline, observed O2 in Intermediate Water (density range of γ = 26.7 – 27.2) shows a declining trend over the past half-century, a trend not explained by the open ocean water mass formation rate
- …