2,358 research outputs found
Effects of a multi-herbal extract on type 2 diabetes
<p>Abstract</p> <p>Background</p> <p>An aqueous extract of multi-hypoglycemic herbs of <it>Panax ginseng </it>C.A.Meyer, <it>Pueraria lobata, Dioscorea batatas Decaisne, Rehmannia glutinosa, Amomum cadamomum Linné, Poncirus fructus </it>and <it>Evodia officinalis </it>was investigated for its anti-diabetic effects in cell and animal models.</p> <p>Methods</p> <p>Activities of PPARγ agonist, anti-inflammation, AMPK activator and anti-ER stress were measured in cell models and in <it>db/db </it>mice (a genetic animal model for type 2 diabetes).</p> <p>Results</p> <p>While the extract stimulated PPARγ-dependent luciferase activity and activated AMPK in C2C12 cells, it inhibited TNF-α-stimulated IKKβ/NFkB signaling and attenuated ER stress in HepG2 cells. The <it>db/db </it>mice treated with the extract showed reduced fasting blood glucose and HbA<sub>1c </sub>levels, improved postprandial glucose levels, enhanced insulin sensitivity and significantly decreased plasma free fatty acid, triglyceride and total cholesterol.</p> <p>Conclusion</p> <p>The aqueous extract of these seven hypoglycemic herbs demonstrated many therapeutic effects for the treatment of type 2 diabetes in cell and animal models.</p
Tensile property improvement of TWIP-cored three-layer steel sheets fabricated by hot-roll-bonding with low-carbon steel or interstitial-free steel
TWIP-cored three-layer steel sheets were newly fabricated by hot rolling of TWIP steel sheet surrounded by low-carbon (LC) or interstitial-free (IF) steel sheets. TWIP/LC or TWIP/IF interfaces were well bonded without pores or voids, while a few pearlites were thinly formed along the interfaces. The strengths and elongation of the TWIP-cored sheets increased as the volume fraction of TWIP-cored region increased, and were also well matched with the ones calculated by a rule of mixtures based on volume fraction or force fraction. According to digital image correlation and electron back-scatter diffraction analyses, very high strain hardening effect in the initial deformation stage and active twin formation in the interfacial region beneficially affected the overall homogeneous deformation in the TWIP-cored sheets without any yield point phenomenon occurring in the LC sheet and serrations occurring in the TWIP sheet, respectively. These TWIP-cored sheets can cover a wide range of yield strength, tensile strength, and ductility levels, e.g., 320-498 MPa, 545-878 MPa, and 48-54%, respectively, by controlling the volume fraction of TWIP-cored region, and thus present new applications to multi-functional automotive steel sheets requiring excellent properties.1163Ysciescopu
Structural safety inspection of reinforced concrete structures considering failure probabilities of structural members
Regular safety inspections of existing reinforced concrete (RC) structures are required according to the regulations and criteria set by each country. In South Korea, the safety inspection regulations provided by the Korea Infrastructure Safety and Technology Corporation (KISTEC) are followed. These regulations were developed based on fuzzy theory to avoid subjective decisions, and provide standardized deterioration grades for member types, floors, and the entire structure. However, the safety inspection regulation by the KISTEC often provides unconservative evaluation results. In particular, as the importance factors of beam and slab members are set lower than those of other members, there are cases in which deteriorations occurring in beams and slabs are not properly reflected in the floor level evaluation. In this study, to overcome such limitations, case studies were carried out and modified importance factors for structural member types were proposed considering the failure probabilities of each member type based on the reliability theory. The importance modification factor was calculated based on the strength ratio of structural members so that the more dangerous the members are, the more impact they give on the evaluation. Overall, compared to the KISTEC method, the proposed method provided conservative but practical assessment results, and it was found that the proposed importance factors can be very useful to properly reflect the effects of damaged members on the deterioration status evaluation of the floors and the entire structure
Development of a Specific and Rapid Diagnostic Method for Detecting Influenza A (H1N1) pdm09 Virus Infection Using Immunochromatographic Assay
AbstractObjectivesThe aim of this study was to develop an immunochromatographic assay (ICA) for the detection of influenza A (H1N1) pdm09 virus infection.Materials and methodsSeveral monoclonal antibodies against influenza A (H1N1) pdm09 virus were generated and an ICA (pdm09-ICA) was developed for the rapid and specific detection of influenza A (H1N1) pdm09 virus infection. The specificity and sensitivity of the developed assay were compared with that of hemagglutination assay and real-time reverse-transcription polymerase chain reaction (rRT-PCR).ResultsThe detection limit was estimated to be 1/2 (8) hemagglutinating unit; the sensitivity and specificity rates of pdm09-ICA were 75.86% (110/145) and 100% (43/43), respectively, compared with rRT-PCR. The cross-reactivity for 20 influenza viruses, including seasonal H1N1 viruses, was found to be negative except for the H1N1 virus (A/Swine/Korea/GC0503/2005).ConclusionThese results indicate that the proposed method can be easily used for rapid and specific detection of the pdm09 infection. The assay developed in this study would be a useful tool for distinguishing the pdm09 infection from seasonal influenza A and B infections
Electro-Mechanical Safety Testing of Portable ECG Devices for Home Healthcare Usage
OBJECTIVES: This paper suggests the experimental guidelines to evaluate the electro-mechanical safety of belt type equipment. The electro-mechanical safety was determined by using the International Electrotechnical Commission guidelines, which are widely used as important factors for assessing the electro-mechanical safety of belt type equipment. However, the local guidelines on wearable healthcare sensors are currently not well-established. Therefore, safety guidelines suited for the actual circumstances in Korea are required, and this paper attempts to try a new experimental safety test procedure of the wearable healthcare sensor. METHODS: This belt type device measures the electrocardiogram (ECG) and heart rates by attaching to the chest. Examination lists were selected by analyzing the common standards ofelectro-mechanical safety (IEC 60601-1) and environment tests (IEC 60068-1, IEC 60068-2) of home-healthcare equipment. RESULTS: The essential electrical safety, which was required for the RS300G3 as a medical device, was evaluated, and most of the examination lists were selected by considering the circumstances of the users. The device passed all the selected examinable lists that are applicable to the Korean environment. CONCLUSIONS: This study has limitations to estimate and to conduct electro-mechanical safety experiments because our study focused on the belt type of heart-rates equipment. We are not taking into account the overall electro-mechanical home-healthcare measurements. According to industrial and technological development, there are infinite possibilities for the advancement of home-healthcare equipment, so more examination lists for safety are being added in addition to what we have doneope
Recommended from our members
Body Map of Droplet Distributions During Oropharyngeal Suction to Protect Health Care Workers From Airborne Diseases.
PURPOSE: Health care workers (HCWs), and in particular anesthesia providers, often must perform aerosol-generating medical procedures (AGMPs). However, no studies have analyzed droplet distributions on the bodies of HCWs during AGMPs. Therefore, the purpose of this study was to assess and analyze droplet distributions on the bodies of HCWs during suction of oral cavities with and without oral airways and during extubations. DESIGN: Using a quasi-experiemental design, we assumed the HCWs perform suction and extubation on intubated patients, and we prepared an intubated mannequin mimicking a patient. This study performed the oral suction and extubation on the intubated mannequin (with or without oral airways in place) and analyzed the droplet distributions. METHODS: We prepared a mannequin intubated with an 8.0 mm endotracheal tube, assuming the situation of general anesthesia. We designed the body mapping gown, and divided it into 10 areas including the head, neck, chest, abdomen, upper arms, forearms, and hands. We classified experiments into group O when suctions were performed on the mannequin with an oral airway, and into group X when the suctions were performed on the mannequin without an oral airway. An experienced board-certified anesthesiologist performed 10 oral suctions on each mannequin, and 10 extubations. We counted the droplets on the anesthesiologists gown according to the divided areas after each procedure. FINDINGS: The mean droplet count after suction was 6.20 ± 2.201 in group O and 13.6 ± 4.300 in group X, with a significant difference between the two groups (P < .001). The right and left hands were the most contaminated areas in group O (2.8 ± 1.033 droplets and 2.0 ± 0.943 droplets, respectively). The abdomen, right hand, left forearm, and left hand showed many droplets in group X. (1.3 ± 1.337 droplets, 3.1 ± 1.792 droplets, 3.2 ± 3.910 droplets, and 4.3 ± 2.214 droplets, respectively). The chest, abdomen, and left hand presented significantly more droplets in group X than in group O. The trunk area (chest and abdomen) was exposed to more droplets during extubations than during suctions. CONCLUSIONS: During suctions, more droplets are splattered from mannequins without oral airways than from those with oral airways. The right and left hands were the most contaminated areas in group O. Moreover, the abdomen, right hand, left forearm, and left hand presented a lot of droplets in group X. In addition, extubations contaminate wider areas (the head, neck, chest and abdomen) of an HCW than suctions
Microspinning: Local Surface Mixing via Rotation of Magnetic Microparticles for Efficient Small-Volume Bioassays
The need for high-throughput screening has led to the miniaturization of the reaction volume of the chamber in bioassays. As the reactor gets smaller, surface tension dominates the gravitational or inertial force, and mixing efficiency decreases in small-scale reactions. Because passive mixing by simple diffusion in tens of microliter-scale volumes takes a long time, active mixing is needed. Here, we report an efficient micromixing method using magnetically rotating microparticles with patterned magnetization induced by magnetic nanoparticle chains. Because the microparticles have magnetization patterning due to fabrication with magnetic nanoparticle chains, the microparticles can rotate along the external rotating magnetic field, causing micromixing. We validated the reaction efficiency by comparing this micromixing method with other mixing methods such as simple diffusion and the use of a rocking shaker at various working volumes. This method has the potential to be widely utilized in suspension assay technology as an efficient mixing strategy
Production of Genetically Stable and Odontoglossum Ringspot Virus-Free Cymbidium Orchid ‘New True’ Plants via Meristem-Derived Protocorm-Like Body (Plb) Subcultures
BACKGROUND: This study aimed to produce Odontoglossum ringspot virus (ORSV)-free Cymbidium orchid \u27New True\u27 plants from ORSV-infected mother plants by culturing their meristems and successively repeating subcultures of protocorm-like bodies (PLBs) derived from the meristems.
RESULTS: Initially, ORSV was confirmed as the causative agent of viral symptoms in orchid leaves via reverse transcription-polymerase chain reaction (RT-PCR) analysis. Meristems from infected plants were cultured to generate PLBs, which in sequence were repeatedly subcultured up to four times. RT-PCR and quantitative RT-PCR analyses revealed that while ORSV was undetectable in shoots derived from the first subculture, complete elimination of the virus required at least a second subculture. Genetic analysis using inter-simple sequence repeat markers indicated no somaclonal variation between regenerated plants and the mother plant, suggesting that genetic consistency was maintained.
CONCLUSION: Overall, our findings demonstrate that subculturing PLBs for a second time is ideal for producing genetically stable, ORSV-free Cymbidium orchids, thus offering a practical means of generating genetically stable, virus-free plants and enhancing plant health and quality in the orchid industry
- …